6. From inside the chassis, pivot the upper retaining clip
1
that secures the plastic holder of the thermal
sensor downward and then push the clip outward to release the clip. Then disengage the plastic
holder holding the thermal sensor from the chassis.
Figure 81. Removing the thermal sensor
7. Pull the entire thermal sensor out of the chassis.
Chapter 8
.
Replacing FRUs (machine types: 10A0, 10A1, 10A6, 10A7, 10AG, 10AK, 10AL, and 10BE)