Diagnostic Error Code
FRU/Action
030-196-XXX
SCSI interface test halt, error threshold
exceeded
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
030-197-XXX
SCSI interface test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 53.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
030-198-XXX
SCSI interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 53.
2. Flash the system and re-test. See “Flash update
procedures” on page 127.
3. Go to “Undetermined problems” on page 78.
030-199-XXX
SCSI interface test failed, cause unknown
1. Go to “Undetermined problems” on page 78.
2. Flash the system and re-test. See “Flash update
procedures” on page 127.
3. Replace component under function test.
035-000-XXX
RAID interface Test Passed
No action
035-0XX-XXX
RAID interface Failure
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
035-195-XXX
RAID interface Test aborted by user
Information only Restart the test, if necessary.
035-196-XXX
RAID interface test halt, error threshold
exceeded
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
035-197-XXX
RAID interface test warning
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 53.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
035-198-XXX
RAID interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 53.
2. Flash the system and re-test. See “Flash update
procedures” on page 127.
3. Go to “Undetermined problems” on page 78.
035-199-XXX
RAID interface test failed, cause unknown
1. See “Undetermined problems” on page 78.
2. Flash the system and re-test. See “Flash update
procedures” on page 127.
3. Replace component under function test.
071-000-XXX
Audio port Interface Test Passed
No action
Chapter 7
.
Symptom-to-FRU Index
69
Содержание ThinkCentre Edge 72z
Страница 1: ...ThinkCentre Edge Hardware Maintenance Manual Machine Types 3569 3571 and 3574 ...
Страница 2: ......
Страница 3: ...ThinkCentre Edge Hardware Maintenance Manual Machine Types 3569 3571 and 3574 ...
Страница 8: ...2 ThinkCentre Edge Hardware Maintenance Manual ...
Страница 15: ...Chapter 2 Safety information 9 ...
Страница 16: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkCentre Edge Hardware Maintenance Manual ...
Страница 19: ...Chapter 2 Safety information 13 ...
Страница 20: ...1 2 14 ThinkCentre Edge Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 15 ...
Страница 27: ...Chapter 2 Safety information 21 ...
Страница 31: ...Chapter 2 Safety information 25 ...
Страница 38: ...32 ThinkCentre Edge Hardware Maintenance Manual ...
Страница 62: ...56 ThinkCentre Edge Hardware Maintenance Manual ...
Страница 89: ...Figure 3 Locating major FRUs and CRUs Chapter 8 Locations 83 ...
Страница 99: ...Figure 13 Reinstall the rubber on the foot stand Chapter 9 Replacing FRUs 93 ...
Страница 132: ...126 ThinkCentre Edge Hardware Maintenance Manual ...
Страница 136: ...130 ThinkCentre Edge Hardware Maintenance Manual ...
Страница 141: ......
Страница 142: ...Part Number Printed in USA 1P P N ...