C-4
Glossary of Terms and Abbreviations
The ServeRAID M5120 SAS/SATA controller is a versatile controller that
provides the backbone of both server and high-end workstation
environments. Each port on the RAID controller supports SAS devices
and/or SATA devices.
SAS device
Any device that conforms to the SAS standard and is attached to the
SAS bus by a SAS cable. This includes SAS storage controllers
(host controllers) and SAS peripherals.
SATA
Acronym for Serial Advanced Technology Attachment. A physical storage
interface standard, SATA is a serial link that provides point-to-point
connections between devices. The thinner serial cables allow for better
airflow within the system and permit smaller chassis designs.
SMP
Acronym for Serial Management Protocol. SMP enables communicates
topology management information directly with an attached SAS
expander device. Each PHY on the controller can function as an SMP
initiator.
SSD
Acronym for Solid State Devices. A Solid State Device uses solid-state
memory to store data. They have no moving parts and are faster and
more reliable than hard disk drives (HDDs).
SSP
Acronym for Serial SCSI Protocol. SSP enables communication with
other SAS devices. Each PHY on the SAS controller can function as an
SSP initiator or SSP target.
STP
Acronym for Serial Tunneling Protocol. STP enables communication with
a SATA device through an attached expander. Each PHY on the SAS
controller can function as an STP initiator.
stripe size
The total disk space consumed by a stripe not including a parity disk. For
example, consider a stripe that contains 64 Kbytes of disk space and has
16 Kbytes of data residing on each disk in the stripe. In this case, the
stripe size is 64 Kbytes and the strip size is 16 Kbytes. The stripe depth
is four (four physical disks in the stripe). You can specify stripe sizes of
8 Kbytes, 16 Kbytes, 32 Kbytes, or 64 Kbytes for each virtual disk. A
larger stripe size produces improved read performance, especially if
most of the reads are sequential. For mostly random reads, select a
smaller stripe size.
striping
Disk striping writes data across two or more disks. Each stripe spans two
or more disks but consumes only a portion of each disk. Each disk,
Содержание ServeRAID M5120
Страница 1: ...ServeRAID M5120 SAS SATA Controller USER S GUIDE ...
Страница 3: ...iii Safety ...
Страница 4: ...iv ...
Страница 5: ...v ...
Страница 6: ...vi Safety Statements ...
Страница 7: ...vii ...
Страница 8: ...viii ...
Страница 10: ...x ...
Страница 14: ...xiv Contents ...
Страница 16: ...xvi Contents ...
Страница 18: ...xviii Contents ...
Страница 54: ...ServeRAID M5120 SAS SATA Controller User s Guide A 1 Appendix A Getting Help and Technical Assistance ...
Страница 55: ...A 2 Getting Help and Technical Assistance A 1 Before You Call ...
Страница 57: ...A 4 Getting Help and Technical Assistance A 4 Software Service and Support A 5 Hardware Service and Support ...
Страница 58: ...Taiwan Product Service A 5 A 6 Taiwan Product Service ...
Страница 59: ...ServeRAID M5120 SAS SATA Controller User s Guide B 1 Appendix B Notices ...
Страница 60: ...B 2 Notices B 1 Trademarks ...
Страница 61: ...Important Notes B 3 B 2 Important Notes ...
Страница 64: ...B 6 Notices B 5 4 European Union EMC Directive Conformance Statement ...
Страница 65: ...Electronic Emission Notices B 7 B 5 5 Germany Class A Statement ...
Страница 66: ...B 8 Notices B 5 6 Japan VCCI Class A Statement ...
Страница 68: ...B 10 Notices B 5 10 Taiwan Class A Compliance Statement ...
Страница 74: ...P N 81Y1008 ...