4. If the problem remains, contact your IBM technical-support representative.
Related links
– Lenovo Support website
– Latest level of DSA
DSA checkpoint panel test results
The following messages can result when you run the checkpoint panel test.
Test results for the DSA checkpoint panel test
The following messages can result when you run the DSA checkpoint panel test.
•
180-000-000 : Check-point Panel Test Passed
Check-point Panel Test Passed.
Recoverable
No
Severity
Event
Serviceable
No
Automatically notify support
No
Related links
– Lenovo Support website
– Latest level of DSA
•
180-801-000 : Check-point Panel Test Aborted
Check-point Panel Test Aborted. BMC is unable to verify that the operator information panel cable is
connected.
Recoverable
No
Severity
Warning
Serviceable
Yes
Automatically notify support
No
User Response
Complete the following steps:
1. Inspect and reseat operator information panel cable at both ends.
2. Verify that the Baseboard Management Controller (BMC) is working.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service
Guide" for the next corrective action.
Related links
Appendix C. DSA diagnostic test results
731
Содержание NeXtScale n1200
Страница 115: ...Chapter 6 Removing and replacing server components 101 ...
Страница 117: ...Chapter 6 Removing and replacing server components 103 ...
Страница 119: ...Chapter 6 Removing and replacing server components 105 ...
Страница 135: ...Chapter 6 Removing and replacing server components 121 ...
Страница 137: ...Chapter 6 Removing and replacing server components 123 ...
Страница 139: ...Chapter 6 Removing and replacing server components 125 ...
Страница 869: ...Taiwan Class A compliance statement Appendix E Notices 855 ...