Improving Performance with a Cache Storage Pool
A cache Storage Pool is a pool of solid-state drives designed to increase read and write performance on
your px6-300d Network Storage. You create a cache Storage Pool and then associate a
volume
on a data
Storage Pool to the cache pool. You can create only one cache Storage Pool on your px6-300d.
To Add a Cache Storage Pool
You first create a cache Storage Pool to begin improving performance.
1. On the Drive Management page, click
Add Storage Pool.
2. In the Information section, enter a name for the cache Storage Pool.
3. To set the RAID protection, choose a value from the drop-down menu:
●
JBOD
Uses all of the storage space for data, providing contiguous storage space spanning all
member drives. Does not protect against data loss in the event of drive failure.
●
None (RAID 0)
Uses all of the storage space for data. Does not protect against data loss in the event of drive
failure.
●
Mirror Stripe (RAID 10)
Uses half of the storage space for protection, leaving half for actual data. Protects data in the
event of a single drive failure.
●
Parity (RAID 5)
Uses the space corresponding to one drive-size for protection, leaving remaining space for
storing actual data.
●
Double Parity (RAID 6)
Combines six or more drives in a way that protects data against loss of any two drives.
4. Select the checkbox of the solid-state drive or drives you want to add to the cache pool. You can
only designate SSDs as cache pool drives if they have not already been assigned to an existing
Storage Pool. All drives in a Storage Pool must be the same size.
Typically, you create a cache Storage Pool with one solid-state drive. However, if you create a
cache pool with at least two SSD drives and apply a redundant RAID protection, such as
mirroring, you can prevent against data losses in the event one of the SSDs fails.
5. Check Enable periodic consistency check to enable a monthly parity or mirror consistency
check.
6. Check Use for SSD Cache.
7. Click Create to add the new Storage Pool.
8. Click Cancel to discard any changes.
Assigning a Cache Pool to a Volume
After creating a cache Storage Pool, you assign a volume from a data Storage Pool to the cache pool. A
cache pool can be assigned to an existing or new volume.
Storage Pool Management
52
Improving Performance with a Cache Storage Pool
Содержание LENOVOEMC PX6-300D
Страница 1: ...px6 300d Network Storage with LifeLine 4 0 User Guide ...
Страница 11: ...Setting up Your px6 300d Network Storage Setting up Your px6 300d Network Storage 1 CHAPTER 1 ...
Страница 33: ...Sharing Files Sharing Files 23 CHAPTER 2 ...
Страница 52: ...Sharing Files 42 One touch Transferring of Content from a USB Device ...
Страница 58: ...iSCSI Creating IP Based Storage Area Networks SAN 48 Deleting iSCSI Drives ...
Страница 59: ...Storage Pool Management Storage Pool Management 49 CHAPTER 4 ...
Страница 72: ...Storage PoolManagement 62 Changing RAID Protection Types ...
Страница 73: ...Drive Management Drive Management 63 ...
Страница 76: ...Drive Management 66 Managing Drives ...
Страница 77: ...Backing up and Restoring Your Content Backing up and Restoring Your Content 67 CHAPTER 6 ...
Страница 121: ...Sharing Content Using Social Media Sharing Content Using Social Media 111 CHAPTER 9 ...
Страница 127: ...Media Management Media Management 117 CHAPTER 10 ...
Страница 139: ... Delete a torrent job Click to delete the torrent download Media Management Torrents 129 ...
Страница 144: ...Media Management 134 Videos ...
Страница 149: ...Upgrading Your px6 300d Network Storage Upgrading Your px6 300d Network Storage 139 CHAPTER 12 ...
Страница 152: ...Upgrading Your px6 300d Network Storage 142 Software Updates ...
Страница 155: ...Hardware Management Hardware Management 145 CHAPTER 14 ...
Страница 166: ...Hardware Management 156 Troubleshooting Routers ...
Страница 167: ...Additional Support Additional Support 157 CHAPTER 15 ...
Страница 170: ...AdditionalSupport 160 Support ...
Страница 171: ...Legal Legal 161 CHAPTER 16 ...