background image

Network adapters

The x3750 M4, machine type 8753 (using Intel Xeon E5-4600 v2 processors) offers a dedicated Mezzanine

LOM slot for integrated networking. In addition to the usual networking functions for the installed operating

system, this adapter also supports shared access to the IMM2 service processor if so enabled in UEFI. The

following table lists the supported ML2 adapters that are installed in this slot. Only one adapter is

supported.

Table 13. Mezzanine LOM network adapters

Part number

Feature
code

Description

Maximum
supported

10 Gb Ethernet
00D2026

A40S

Broadcom NetXtreme II ML2 Dual Port 10GbaseT for System x

1*

00D2028

A40T

Broadcom NetXtreme II ML2 Dual Port 10GbE SFP+ for System x

1*

00AG560

AT7U

Emulex VFA5.2 ML2 Dual Port 10GbE SFP+ Adapter

1*

00D1996

A40Q

Emulex VFA5 ML2 Dual Port 10GbE SFP+ Adapter for System x

1*

00D8544

A4NZ

Emulex VFA5 ML2 FCoE/iSCSI License for System x (FoD)
(FCoE/iSCSI upgrade for 00D1996 or 00D8544)

1

00D1998

A40R

Intel I350-T4 ML2 Quad Port GbE Adapter for System x

1*

00D1994

A40P

Intel X540 ML2 Dual Port 10GbaseT Adapter for System x

1*

94Y5200

AS74

Intel X710 ML2 4x10GbE SFP+ Adapter for System x

1*

00FP650

A5RK

Mellanox ConnectX-3 Pro ML2 2x40GbE/FDR VPI Adapter

1*

1 Gb Ethernet
00D1998

A40R

Intel I350-T4 ML2 Quad Port GbE Adapter for System x

1*

* These ML2 adapters occupy the same dedicated slot and are mutually exclusive.

The following table lists additional supported network adapters that can be installed in the eight regular

PCIe slots.

Table 14. Network adapters

Part number

Feature
code

Description

Maximum
supported#

40 Gb Ethernet / InfiniBand
00D9550

A3PN

Mellanox ConnectX-3 40GbE / FDR IB VPI Adapter for System x

8

10 Gb Ethernet
94Y5180

A4Z6

Broadcom NetXtreme Dual Port 10GbE SFP+ Adapter for System x

8

44T1370

A5GZ

Broadcom NetXtreme 2x10GbE BaseT Adapter for System x

8

00AG570

AT7S

Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter

8

00AG580

AT7T

Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW

8

00JY820

A5UT

Emulex VFA5 2x10 GbE SFP+ PCIe Adapter for System x

8

00JY830

A5UU

Emulex VFA5 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW

8

00D8540

A4M9

Emulex Dual Port 10GbE SFP+ VFA IIIr for System x

8

49Y7960

A2EC

Intel X520 Dual Port 10GbE SFP+ Adapter for System x

8

49Y7970

A2ED

Intel X540-T2 Dual Port 10GBaseT Adapter for System x

8

81Y3520

AS73

Intel X710 2x10GbE SFP+ Adapter for System x

8

00D9690

A3PM

Mellanox ConnectX-3 10 GbE Adapter for System x

8

Lenovo System x3750 M4 (8753)

18

Содержание 8753

Страница 1: ...5 Suggested uses High performance computing HPC workloads with floating point computations and small to medium databases requiring fast I O applications that require 4 socket performance without needing the scalability that the X6 systems provide Figure 1 The Lenovo System x3750 M4 Did you know With a dense 2U design the Lenovo System x3750 M4 provides advanced features and capabilities These incl...

Страница 2: ...ads by temporarily going beyond processor TDP Intel Hyper Threading Technology boosts performance for multithreaded applications by enabling simultaneous multithreading within each processor core up to two threads per core Intel Virtualization Technology integrates hardware level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads 48 Loa...

Страница 3: ...C checking Diskette CRC checking USB CRC checking Over temperature detection Over under voltage detection Power supply error checking Fan failure detection Serial interface parity overrun and frame checking Solid state drives SSDs offer more reliability than traditional mechanical HDDs for greater uptime The built in Integrated Management Module Version II IMM2 continuously monitors system paramet...

Страница 4: ...its into the same TDP limits Intel Intelligent Power Capability powers individual processor elements on and off as needed to reduce power draw Low voltage Intel Xeon processors draw less energy to satisfy the demands of power and thermally constrained data centers and telecommunication environments Low voltage 1 35 V DDR3 memory RDIMMs consume 19 less energy compared to 1 5 V DDR3 RDIMMs Solid sta...

Страница 5: ...rver Figure 3 Rear view of the Lenovo System x3750 M4 machine type 8753 The following figure shows the locations of key components inside the server Figure 4 Inside view of the Lenovo System x3750 M4 machine type 8753 Lenovo System x3750 M4 8753 5 ...

Страница 6: ... memory sparing Disk drive bays Up to 16 2 5 inch hot swap SAS SATA bays Maximum internal storage Up to 28 8 TB with 1 8 TB 2 5 SAS HDDs Up to 25 6 TB with 1 6 TB 2 5 SSDs up to 16 TB with 1 TB 2 5 NL SAS SATA HDDs Intermix of SAS SATA supported RAID support RAID 0 1 10 with integrated ServeRAID M5210e with LSI SAS3108 RAID on Chip ROC controller Optional upgrades to RAID 5 and 50 are available 1G...

Страница 7: ...UEFI Integrated Management Module II IMM2 Predictive Failure Analysis Light Path Diagnostics Automatic Server Restart Lenovo XClarity Administrator and the ServerGuide IMM Advanced Upgrade software feature for remote presence are standard with the x3750 M4 Security features Power on password administrator s password Trusted Platform Module TPM Operating systems supported Microsoft Windows Server R...

Страница 8: ...2x 8 GB 1600 MHz M5210e 1GB F R5 4x 2 5 16 max Open 5 8 2x 10GbE 1x 900W Processor detail Processor quantity and model cores core speed L3 cache memory speed and power consumption All models except for 8753 A2x include the processor and memory expansion tray containing sockets for processors 3 and 4 and 24 DIMMs For model A2x order part number 88Y7365 Model 8753 C2x includes the Broadcom NetXtreme...

Страница 9: ...8C 3 3GHz 16MB 1866MHz 130W 8753 A1x 00D0574 A452 A453 Intel Xeon E5 4624L v2 10C 1 9GHz 25MB 1866MHz 70W 00D1968 A43P A43Y Intel Xeon E5 4640 v2 10C 2 2GHz 20MB 1866MHz 95W 8753 C1x 00D1973 A43Q A43Z Intel Xeon E5 4650 v2 10C 2 4GHz 25MB 1866MHz 95W 8753 C2x 00D1988 A43T A442 Intel Xeon E5 4657L v2 12C 2 4GHz 30MB 1866MHz 115W The first feature code corresponds to the first processor installed th...

Страница 10: ...imum number of ranks per one channel is eight with the exception of Load Reduced DIMMs where more than eight ranks are supported because one quad rank LRDIMM provides the same electrical load on a memory bus as a single rank RDIMM The maximum quantity of DIMMs that can be installed in the server depends on the number of processors installed The table shows the maximum when all four processors are ...

Страница 11: ...per channel 1066 MHz 1333 MHz 1333 MHz 1066 MHz 1333 MHz 1333 MHz 1333 MHz Maximum quantity supported is shown for four processors installed When two processors are installed the maximum quantity supported is a half of the quantity that is shown When one processor is installed the quantity is one quarter of that shown The following memory protection technologies are supported ECC Chipkill for x4 b...

Страница 12: ...ignal cable except when the 8 drive backplane with SAS expander is used When the 8 drive backplane with SAS expander is used the other backplanes connect to the SAS expander backplane with the supplied cables and then the SAS expander backplane is connected to the single RAID controller with two cables All backplane options include the necessary cables See the System x3750 M4 Installation and Serv...

Страница 13: ...SAS3108 RAID on Chip ROC controller Eight internal SAS SATA ports Two internal x4 HD Mini SAS connectors SFF 8643 PCI Express 3 0 x8 host interface Support for RAID 0 1 and 10 standard Support for RAID 5 50 6 and 60 with optional upgrades Optional onboard data cache 1 GB no battery backup or 1 or 2 GB with flash backup Optional support for self encrypting drives SEDs with MegaRAID SafeStore Note T...

Страница 14: ...8 A3Z3 ServeRAID M5200 Series 4GB Flash RAID 5 Upgrade Hardware 4 47C8706 A3Z5 ServeRAID M5200 Series RAID 6 Upgrade FoD FoD 1 47C8708 A3Z6 ServeRAID M5200 Series Zero Cache RAID 5 FoD FoD 1 47C8710 A3Z7 ServeRAID M5200 Series Performance Accelerator FoD FoD 1 47C8712 A3Z8 ServeRAID M5200 Series SSD Caching Enabler FoD FoD 1 00AE930 A5H5 ServeRAID M1200 Zero Cache RAID 5 Upgrade for Systems FOD Fo...

Страница 15: ... SFF HS HDD 16 2 5 inch hot swap HDDs 6 Gb NL SATA 81Y9726 A1NZ 500GB 7 2K 6Gbps NL SATA 2 5 SFF HS HDD 16 81Y9730 A1AV 1TB 7 2K 6Gbps NL SATA 2 5 SFF HS HDD 16 2 5 inch hot swap SED HDDs 6 Gb SAS 10K 90Y8913 A2XF 300GB 10K 6Gbps SAS 2 5 SFF G2HS SED 16 90Y8908 A3EF 600GB 10K 6Gbps SAS 2 5 SFF G2HS SED 16 Table 10 2 5 inch hot swap 6 Gb SAS SATA SSDs Part number Feature Description Maximum support...

Страница 16: ...se Multi Burner drives 00MV945 and 46M0902 supports the following media and speeds for reading CD ROM 24X CD DA DAE 20X CD R 24X CD RW 24X DVD ROM single layer 8X DVD ROM dual layer 8X DVD R 4 7 GB 6X DVD R DL 4X DVD R 6X DVD R DL 4X DVD RW 4 7 GB 4X DVD RW 4X DVD RAM 4 7 9 4 GB 4X The drives also support the following media and speeds for writing CD R 24X CD RW 4X High Speed CD RW 10X Ultra Speed...

Страница 17: ...PCIe 3 x8 riser are as follows Slot 1 PCIe 3 0 x8 x16 mechanical Full height half length requires processor 2 Slot 2 PCIe 3 0 x8 x16 mechanical Full height half length requires processor 2 Slot 3 PCIe 3 0 x8 x16 mechanical Full height half length requires processor 2 The two slots on the PCIe 1x16 and 1x8 riser are as follows Slot 1 PCIe 3 0 x16 Full height half length requires processor 2 Slot 2 ...

Страница 18: ...FP Adapter for System x 1 00FP650 A5RK Mellanox ConnectX 3 Pro ML2 2x40GbE FDR VPI Adapter 1 1 Gb Ethernet 00D1998 A40R Intel I350 T4 ML2 Quad Port GbE Adapter for System x 1 These ML2 adapters occupy the same dedicated slot and are mutually exclusive The following table lists additional supported network adapters that can be installed in the eight regular PCIe slots Table 14 Network adapters Part...

Страница 19: ... Networking adapters category https lenovopress com servers options ethernet The following table lists the supported 10 Gb Ethernet SFP optical transceivers and DAC cables For multi port adapters all adapter ports must have the same type of transceiver or DAC cable selected Table 15 Supported optical transceivers and DAC cables 10 Gb Ethernet Part number Feature code Description 10 GbE SFP LR tran...

Страница 20: ... ATZU Emulex 16Gb Gen6 FC Single port HBA 8 01CV840 ATZV Emulex 16Gb Gen6 FC Dual port HBA 8 01CV750 ATZB QLogic 16Gb Enhanced Gen5 FC Single port HBA 8 01CV760 ATZC QLogic 16Gb Enhanced Gen5 FC Dual port HBA 8 81Y1662 A2W6 Emulex 16Gb FC Dual port HBA for System x 8 81Y1655 A2W5 Emulex 16Gb FC Single port HBA for System x 8 00Y3341 A3KX QLogic 16Gb FC Dual port HBA for System x 8 00Y3337 A3KW QLo...

Страница 21: ...00 Series RAID 6 Upgrade 1 per server 90Y4273 A2MC ServeRAID M5100 Series SSD Performance Accelerator 1 per server 90Y4318 A2MD ServeRAID M5100 Series SSD Caching Enabler 1 per server Upgrades for the ServeRAID M5225 47C8710 A3Z7 ServeRAID M5200 Series Performance Accelerator 1 per server 47C8706 A3Z5 ServeRAID M5200 Series RAID 6 Upgrade 1 per server 47C8712 A3Z8 ServeRAID M5200 Series SSD Cachin...

Страница 22: ... 1 10 Optional 5 50 6 60 0 1 10 5 50 Optional 6 60 JBOD mode Yes No No Cache None Optional 512MB 1GB or 2GB with flash backup 2 GB included CacheVault cache protection None Flash with cache upgrades Flash included FastPath None Optional 90Y4273 Optional 47C8710 CacheCade Pro 2 0 None Optional 90Y4318 Optional 47C8712 Cache upgrade required The ServeRAID M5120 SAS SATA Controller ships standard wit...

Страница 23: ...hrough CTO or Special Bid Installing a second power supply requires that the processor and memory expansion tray 88Y7365 or the power interposer card 88Y7367 be installed The power interposer card option enables redundancy power support when the processor and memory expansion tray is not installed If you do not have the processor and memory expansion tray installed and want to install two power su...

Страница 24: ...roblem records the error in the event log and alerts you to the problem A virtual presence capability also comes standard in this server for remote server management Remote server management is provided through industry standard interfaces Intelligent Platform Management Interface IPMI Version 2 0 Simple Network Management Protocol SNMP Version 3 Common Information Model CIM Web browser The server...

Страница 25: ... Models where standard Rail slides 81Y6821 A228 Gen III Slides Kit All models 69Y1193 A22B Universal Slides Kit Cable Management Arms 81Y6822 A229 Gen III CMA A2x 69Y1192 A22A Gen III Large Capacity CMA All other models 69Y2346 6473 CMA for Ball Bearing and Universal Slides 69Y2347 6474 2U Cable Management Arm Withdrawn from marketing Operating system support Lenovo System x3750 M4 8753 25 ...

Страница 26: ...rise Server 11 x64 SP4 SUSE Linux Enterprise Server 12 SUSE Linux Enterprise Server 12 SP1 SUSE Linux Enterprise Server 12 SP2 SUSE Linux Enterprise Server 12 SP3 SUSE Linux Enterprise Server 12 Xen SUSE Linux Enterprise Server 12 Xen SP1 SUSE Linux Enterprise Server 12 Xen SP2 SUSE Linux Enterprise Server 12 Xen SP3 VMware ESXi 5 0 U3 VMware ESXi 5 1 U2 VMware ESXi 5 1 U3 VMware ESXi 5 5 U1 VMwar...

Страница 27: ...anty with 24x7 standard call center support and 9x5 Next Business Day onsite coverage Also available are Lenovo Services warranty maintenance upgrades and post warranty maintenance agreements with a well defined scope of services including service hours response time term of service and service agreement terms and conditions Lenovo warranty service upgrade offerings are country specific Not all wa...

Страница 28: ...llowing Lenovo warranty service upgrades are available Warranty and maintenance service upgrades Three four or five years of 9x5 or 24x7 service coverage Onsite response from next business day to 2 or 4 hours Committed repair service Warranty extension of up to 5 years Post warranty extensions Committed Repair Service Committed Repair Services enhances the level of Warranty Service Upgrade or Post...

Страница 29: ...e 4 Class A UL IEC 60950 1 CSA C22 2 No 60950 1 NOM 019 Argentina IEC60950 1 Japan VCCI Class A Australia New Zealand AS NZS CISPR 22 Class A IEC 60950 1 CB Certificate and CB Test Report China CCC GB4943 GB9254 Class A GB17625 1 Taiwan BSMI CNS13438 Class A CNS14336 1 Korea KN22 Class A KN24 Russia GOST ME01 IEC 60950 1 GOST R 51318 22 GOST R 51318 24 GOST R 51317 3 2 and GOST R 51317 3 3 IEC 609...

Страница 30: ... see the Lenovo Press Product Guide http lenovopress com lp0043 The following table lists the standard models of the 12 Gbps SAS external drive enclosures offered by Lenovo that can be used with the server for storage expansion Table 26 D1212 and D1224 standard models Part number Description LFF models 4587A11 D1212 LFF Chassis Dual 3 port ESMs US English documentation 4587A1C D1212 LFF Chassis Du...

Страница 31: ...is Dual 3 port ESMs 12x 8TB 3 5 HDDs 4x 0 5m SAS cables Brazil and Latin America SFF models 4587E6U D1224 SFF Chassis Dual 3 port ESMs 9x 1 2TB 10K HDDs 4x 0 5m SAS cables 4587E2U D1224 SFF Chassis Dual 3 port ESMs 9x 1 2TB 10K HDDs 2x 400GB SSDs 4x 0 5m SAS cables 4587E4U D1224 SFF Chassis Dual 3 port ESMs 9x 1 2TB 10K HDDs 4x 400GB SSDs 4x 0 5m SAS cables 4587E5U D1224 SFF Chassis Dual 3 port ES...

Страница 32: ... 6413E2H Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure 6413E2F Lenovo Storage D3284 8TB x 42 HD Expansion Enclosure 6413E3H Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure 6413E3F Lenovo Storage D3284 10TB x 42 HD Expansion Enclosure 6413E4H Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure 6413E4F For details about supported drives adapters and cables for the Lenovo Storage D3284 ...

Страница 33: ...it Simplified Chinese documentation 4619A2J Lenovo ThinkSystem DS6200 SFF SAS Dual Controller Unit Japanese documentation Lenovo ThinkSystem DS Series Storage iSCSI or FC host connectivity 4599A31 Lenovo ThinkSystem DS2200 LFF FC iSCSI Dual Controller Unit US English documentation 4599A3C Lenovo ThinkSystem DS2200 LFF FC iSCSI Dual Controller Unit Simplified Chinese documentation 4599A3J Lenovo Th...

Страница 34: ...V7000 2 5 inch Storage Controller Unit w 5 Yr S S LA Model 524 6195C32 IBM Storwize V7000 SFF Control Enclosure 3YR SWMA Model HC1 Gen2 6195C3L IBM Storwize V7000 SFF Control Enclosure 3YR SWMA LA Model HC1 Gen2 6195C52 IBM Storwize V7000 SFF Control Enclosure 5YR SWMA Model HC1 Gen2 6195C5L IBM Storwize V7000 SFF Control Enclosure 5YR SWMA LA Model HC1 Gen2 Lenovo Storage DX8200 Series S3 cloud s...

Страница 35: ...51356Wx Lenovo Storage DX8200D ServerSAN High 32TB 5yr SW S S 5128C1x Lenovo Storage DX8200N with 1x N2226 HBA 5128C2x Lenovo Storage DX8200N with 2x N2226 HBAs Part number Description Available worldwide except China and Japan Available only in China Available only in Japan Available worldwide except Latin America Available only in Latin America For more information see the list of Product Guides...

Страница 36: ... Autoloader w LTO7 HH SAS External tape backup libraries 61732UL IBM TS3100 Tape Library Model L2U 61734UL IBM TS3200 Tape Library Model L4U Fibre Channel backup drives for TS3100 and TS3200 Tape Libraries 00NA107 6173 LTO Ultrium 5 Fibre Channel Drive 00NA113 6173 LTO Ultrium 5 Half High Fibre Drive Sled 00NA115 6173 LTO Ultrium 6 Fibre Channel Drive 00NA119 6173 LTO Ultrium 6 Half High Fibre Dri...

Страница 37: ...kSwitch G8264CS Rear to Front 7159CRW Lenovo RackSwitch G8272 Rear to Front 7159GR6 Lenovo RackSwitch G8296 Rear to Front 25 Gb Ethernet switches 7159E1X Lenovo ThinkSystem NE2572 RackSwitch Rear to Front 40 Gb Ethernet switches 7159BRX Lenovo RackSwitch G8332 Rear to Front 100 Gb Ethernet switches 7159D1X Lenovo ThinkSystem NE10032 RackSwitch Rear to Front For more information see the list of Pro...

Страница 38: ...rprise SW 1 PS Rail Kit 3873AR5 Lenovo B6505 12 ports activated w 16Gb SWL SFPs 1 PS Rail Kit 3873BR3 Lenovo B6510 24 ports activated w 16Gb SWL SFPs 2 PS Rail Kit 32 Gb FC 6559D3Y Lenovo ThinkSystem DB610S 8 ports activated 1 PS Rail Kit 6415G11 Lenovo ThinkSystem DB620S 24 Ports Activated 24x 32Gb SWL SFPs 2 PS Rail Kit 6415G2A Lenovo ThinkSystem DB620S 48 Ports Activated 48x 32Gb SWL SFPs 2 PS ...

Страница 39: ...ck or Tower UPS 200 240VAC 55943AX RT3kVA 2U Rack or Tower UPS 100 125VAC 55943KX RT3kVA 2U Rack or Tower UPS 200 240VAC 55945KX RT5kVA 3U Rack or Tower UPS 200 240VAC 55946KX RT6kVA 3U Rack or Tower UPS 200 240VAC 55948KX RT8kVA 6U Rack or Tower UPS 200 240VAC 55949KX RT11kVA 6U Rack or Tower UPS 200 240VAC 55948PX RT8kVA 6U 3 1 Phase Rack or Tower UPS 380 415VAC 55949PX RT11kVA 6U 3 1 Phase Rack...

Страница 40: ...46M4005 1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P Gnd line cord Ultra Density Enterprise PDUs 9x IEC 320 C13 3x IEC 320 C19 outlets 71762NX Ultra Density Enterprise C19 C13 PDU Module without line cord 71763NU Ultra Density Enterprise C19 C13 PDU 60A 208V 3ph with IEC 309 3P Gnd line cord C13 Enterprise PDUs 12x IEC 320 C13 outlets 39M2816 DPI C13 Enterprise PDU without line...

Страница 41: ...eep Static Expansion Rack 93614PX 42U 1200 mm Deep Static Rack 93624EX 47U 1200 mm Deep Static Expansion Rack 93624PX 47U 1200 mm Deep Static Rack 99564RX S2 42U Dynamic Standard Rack 99564XX S2 42U Dynamic Standard Expansion Rack For more information see the list of Lenovo Press Product Guides in the Rack cabinets and options category https lenovopress com servers options racks KVM console option...

Страница 42: ...board w Int Pointing Device USB Russian 441 RoHS v2 46W6733 Keyboard w Int Pointing Device USB Slovak 245 RoHS v2 46W6734 Keyboard w Int Pointing Device USB Spanish 172 RoHS v2 46W6735 Keyboard w Int Pointing Device USB Swed Finn 153 RoHS v2 46W6736 Keyboard w Int Pointing Device USB Swiss F G 150 RoHS v2 46W6737 Keyboard w Int Pointing Device USB Thai 191 RoHS v2 46W6738 Keyboard w Int Pointing D...

Страница 43: ...viced properly As a premier client you have a dedicated finance specialist who manages your account through its life from first invoice through asset return or purchase This specialist develops an in depth understanding of your invoice and payment requirements For you this dedication provides a high quality easy and positive financing experience For your region specific offers please ask your Leno...

Страница 44: ...Related product families Product families related to this document are the following 4 Socket Rack Servers Lenovo System x3750 M4 8753 44 ...

Страница 45: ...nt are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons The information contained in this document does not affect or change Lenovo product specifications or warranties Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third partie...

Страница 46: ...eRAID ServerGuide ServerProven System x ThinkServer ThinkSystem TopSeller UltraNav eXFlash The following terms are trademarks of other companies Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries Linux is a trademark of Linus Torvalds in the United States other countries or both Microsoft Windows Server and Windo...

Отзывы: