Diagnostic Error Code
FRU/Action
005-197-XXX
Video test warning
1.
Make sure the component that is called out is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 39
2. Re-run test
3. Replace the component called out in warning
statement
4. Replace the component under test
005-198-XXX
Video test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 “Using
the Setup Utility” on page 39
2. Flash the system and re-test. See “Updating
(flashing) BIOS from a disc” on page 554
3. Go to “Undetermined problems” on page 65
005-199-XXX
Video test failed, cause unknown
1. Go to “Undetermined problems” on page 65
2. Flash the system and re-test. See “Updating
(flashing) BIOS from a disc” on page 554
3. Replace component under function test
005-2XX-XXX 005-3XX-XXX
Video subsystem error
1.
Video card, if installed
2. System board
006-000-XXX
Diskette interface Test Passed
No action
006-0XX-XXX
Diskette interface error
1.
Diskette drive Cable
2. Diskette drive
3. System board
006-195-XXX
Diskette interface Test aborted by user
Information only
Re-start the test, if necessary
006-196-XXX
Diskette interface test halt, error threshold
exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
006-197-XXX
Diskette interface test warning
1.
If a component is called out, make sure it is
connected and/or enabled
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
006-198-XXX
Diskette interface test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test. See “Updating
(flashing) BIOS from a disc” on page 554
3. Go to “Undetermined problems” on page 65
006-199-XXX
Diskette interface test failed, cause
unknown
1. Go to “Undetermined problems” on page 65
2. Flash the system and re-test
3. Replace component under function test
006-25X-XXX
Diskette interface Error
1.
Diskette drive cable
2. Diskette drive
3. System board
011-000-XXX
Serial port Interface Test Passed
No action
Chapter 7
.
Symptom-to-FRU index
49
Содержание 7360D6U - THINKCENTRE M58 7360
Страница 2: ......
Страница 8: ...vi ThinkCentre Hardware Maintenance Manual ...
Страница 17: ...Chapter 2 Safety information 9 ...
Страница 18: ... 18 kg 37 lbs 32 kg 70 5 lbs 55 kg 121 2 lbs 1 2 PERIGO 10 ThinkCentre Hardware Maintenance Manual ...
Страница 21: ...Chapter 2 Safety information 13 ...
Страница 22: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Страница 23: ...Chapter 2 Safety information 15 ...
Страница 29: ...Chapter 2 Safety information 21 ...
Страница 33: ...Chapter 2 Safety information 25 ...
Страница 50: ...42 ThinkCentre Hardware Maintenance Manual ...
Страница 74: ...66 ThinkCentre Hardware Maintenance Manual ...
Страница 560: ...552 ThinkCentre Hardware Maintenance Manual ...
Страница 564: ...556 ThinkCentre Hardware Maintenance Manual ...