Notes:
• Do not touch the thermal grease.
• Keep the thermal grease off the system board.
Figure 93. Applying the thermal grease to the top of the microprocessor
12. Reinstall the heat sink and fan assembly on the new system board. See “For service technician only:
replacing the heat sink and fan assembly” on page 89.
13. Reinstall other parts that you have removed one by one in the reversed sequence as you remove them.
See “Removing and installing hardware” on page 42.
14. Connect all cables to the system board. See “System board components” on page 19.
If you are instructed to return the old system board, follow all packaging instructions and use any packaging
materials that are supplied to you for shipping. The old system board must be returned with a CPU socket
cover to protect the pins during shipping and handling.
To install the CPU socket cover, do the following:
1. After you have removed the CPU from the old system board, close the CPU retainer and then lock the
small handle to secure the retainer in place.
2. Note the orientation of the socket cover, and install one side of the socket cover into the CPU socket.
Then, carefully press the other side of the socket cover downward until it snaps into position.
Figure 94. Installing the socket cover
3. Carefully check the four corners of the socket cover to ensure that the cover is seated securely.
Completing the parts replacement
To complete the parts replacement, do the following:
1. Ensure that all components have been reassembled correctly and that no tools or loose screws are left
inside your server.
2. Correctly connect the cables in the server. Refer to the cable connecting information for each
component in Replacing hardware.
96
ThinkServer TS150 User Guide and Hardware Maintenance Manual
Содержание 70LU
Страница 16: ...4 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 50: ...38 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 110: ...98 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 116: ...104 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 120: ...108 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 131: ...Taiwan BSMI RoHS declaration Appendix C Restriction of Hazardous Substances RoHS Directive 119 ...
Страница 132: ...120 ThinkServer TS150 User Guide and Hardware Maintenance Manual ...
Страница 141: ......
Страница 142: ......