5. Remove the screw that secures the power conversion board. Then, slide the power conversion board to
the front of the chassis until it is released from the retention posts on the chassis, and then carefully
remove the board out of the chassis.
Figure 67. Removing the power conversion board
6. Touch the static-protective package that contains the new power conversion board to any unpainted
surface on the outside of the server. Then, remove the new power conversion board from the package.
Note:
Carefully handle the power conversion board by its edges.
Chapter 6
.
Installing, removing, or replacing hardware
117