What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the replacement, go to “Completing the parts replacement” on page 82.
Replacing the heat sink and fan assembly
Attention:
Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii and “Guidelines” on page 35.
This topic provides instructions on how to replace the heat sink and fan assembly.
CAUTION:
Turn off the server and wait three to five minutes to let the server cool before removing the server
cover.
To replace the heat sink and fan assembly, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. Remove the server cover. See “Removing the server cover” on page 37.
3. Lay the server on its side for easier access to the system board.
4. Locate the heat sink and fan assembly. See “Locating parts on the system board” on page 15.
5. Disconnect the heat sink and fan assembly cable from the microprocessor fan connector on the system
board. See “Locating parts on the system board” on page 15.
Chapter 6
.
Installing, removing, or replacing hardware
69
Содержание 70A0
Страница 1: ...ThinkServer TS140 Hardware Maintenance Manual Machine Types 70A0 70A1 70A4 and 70A5 ...
Страница 16: ...4 ThinkServer TS140 Hardware Maintenance Manual ...
Страница 18: ...6 ThinkServer TS140 Hardware Maintenance Manual ...
Страница 30: ...18 ThinkServer TS140 Hardware Maintenance Manual ...
Страница 32: ...20 ThinkServer TS140 Hardware Maintenance Manual ...
Страница 102: ...Symptom Action 2 Restart the server 3 Replace the USB device 90 ThinkServer TS140 Hardware Maintenance Manual ...
Страница 106: ...94 ThinkServer TS140 Hardware Maintenance Manual ...
Страница 120: ...108 ThinkServer TS140 Hardware Maintenance Manual ...
Страница 121: ......
Страница 122: ......