Bauer
4 Product description
Indicators
GEL 211CS0
81
E
nglis
h
If the device is operated with a connection to a higher level control system, a
differentiation must be made between two operating modes:
●
Measurement/analysis: No restriction on operation
●
Configuration/calibration: Restriction on operation, as the
MiniCODER plus is temporarily placed in a programming mode in which
“Safety integrated” is no longer ensured.
4.4 Indicators
LED
Colour/flashing pattern
Significance
Power
green
Device supplied with power
green flashing
CPU firmware update in progress
Comm green flashing slowly
Ready for connection
green flashing quickly
WLAN error
green/red flashing
COMM firmware update in progress (WLAN)
green
Connected
red flashing
Activity
Signal
green
SIN/COS level ok
off
SIN/COS level not ok
Status
green
Zero signal quiescent level ok, signal detected
in the last 2 s
blue
Zero signal quiescent level ok, no signal in the
last 2 s
red
Zero signal quiescent level not ok or device is
waiting for position information
LED
Signal
:
Colour and significance correspond to the status field "SIN/COS OK" on the
web interface.
LED
Status
:
Colour and significance correspond to the status field "REF OK" on the web
interface.
Содержание GEL 211CS0