7 Functions of the GEL 211C
Bauer
Spindle histogram group
114
GEL 211CS0
E
nglis
h
After you accept using
Save
, new ranges based on the entries set are generated us-
ing a defined algorithm. You can now select and edit the individual ranges 2 to 7 us-
ing their buttons, if the delay or the hysteresis values need to be modified. You can
also change the range limits.
Once you have defined all the necessary entries, the record can be transferred to the
MiniCODER (
Send
button in the status line at the bottom).
Prior to the execution of this action the following (confirmation) prompts must be an-
swered or accepted:
●
Required entry of a spindle serial number (or other designation) for unique alloca-
tion of the MiniCODER
●
Deletion of already existing operating times in the MiniCODER
After successful transmission, the configuration timestamp in the MiniCODER is ad-
justed correspondingly, i.e. set to the actual duration of operation of the MiniCODER.
7.5.3 Reading
operating
times
(
rpm Operating times
)
Using this function you can retrieve the histogram data from the MiniCODER plus
and save the data in a report as necessary (
Save
button in the status line at the bot-
tom).
Duration of operation in the different speed ranges
The MiniCODER plus saves its operating times at fixed intervals. At least
3 minutes must elapse between two retrieval actions.