INSTALLATION CLEARANCES
DISCONNECT
SWITCH
(By Others)
OPTIONAL
OUTDOOR
THERMOSTAT
LENNOX
INDOOR UNIT
OPTIONAL
ELECTRIC
HEAT
THERMOSTAT
(Optional)
LENNOX
OUTDOOR
UNIT
DISCONNECT
SWITCH
(By Others)
A
B
C
D
A - Two Wire Power (see Electrical Data)
B - Two or Three Wire Power (size to heater capacity)
C - Twelve Wire Low Voltage 18 ga. minimum
Fourteen Wire Low Voltage with Optional Outdoor Thermostat
D - Eight Wire Low Voltage 18 ga. minimum
Ten Wire Low Voltage with Optional Outdoor Thermostat
NOTE - Field Wiring Not Furnished
All wiring must conform to NEC or CEC and local electrical codes.
NOTES:
One of these three sides must be 36 in. (914 mm).
One of the two remaining sides may be 12 in. (305 mm).
The remaining side may be 6 in. (152 mm).
Service Clearance − 30 in. (762 mm)
48 in. (1219 mm)clearance required on top of unit
24 in. (610 mm) required between two units
FIELD WIRING
SOUND DATA
1
Unit
Model No.
Octave Band Sound Power Levels dBA, re 10
-12
Watts
Center Frequency - HZ
1
Sound Rating
Number (dB)
125
250
500
1000
2000
4000
8000
XP17-024
49.4
53.8
58.6
57.8
51.3
46.0
39.7
63
XP17-030
53.5
55.0
61.5
63.0
51.0
45.5
42.5
67
XP17-036
50.4
56.9
63.8
60.5
55.7
50.5
37.9
71
XP17-042
53.4
56.9
62.8
60.0
63.7
50.0
39.4
72
XP17-048
60.5
63.0
67.0
65.5
60.5
54.5
48.0
73
XP17-060
57.0
64.0
69.0
67.0
63.0
57.5
52.0
73
NOTE - the octave sound power data does not include tonal correction.
1
Tested according to AHRI Standard 270-2008 test conditions.