XP17 - 2 to 5 Ton Heat Pump / Page 40
AHRI SYSTEM MATCHES
Model No.
Cooling
Capacity SEER EER
Heat Capacity Heat COP HSPF
(IV)
Coil or
Air Handler
Furnace
AHRI
Reference
High
Low
High Low
XP17-060-230 56,000 14.70 12.20 51,500 35,800 3.30 2.42 8.70 CX34-62C
ML180UH090E60C
4666927
XP17-060-230 56,000 14.70 12.00 51,500 35,800 3.28 2.40 8.70 CX34-62C
ML180UH110E60C
4666928
XP17-060-230 56,000 14.70 12.00 51,500 35,800 3.28 2.40 8.70 CX34-62C
ML180UH110XE60C
4672134
XP17-060-230 56,000 14.70 12.20 51,500 35,800 3.30 2.40 8.70 CX34-62C
SL280UH090V60C
3894879
XP17-060-230 56,000 14.70 12.20 51,500 35,800 3.30 2.40 8.70 CX34-62C
SL280UH090XV60C
4235881
XP17-060-230 56,000 14.70 12.20 51,500 35,800 3.28 2.40 8.70 CX34-62C
SL280UH110V60C
3894880
XP17-060-230 56,000 14.70 12.20 51,500 35,800 3.28 2.40 8.70 CX34-62C
SL280UH110XV60C
4042039
XP17-060-230 55,500 14.50 12.00 51,500 35,800 3.24 2.38 8.50 CX34-62C
SLP98UH090XV60C
5137377
XP17-060-230 55,500 14.70 12.20 51,000 35,600 3.22 2.38 8.50 CX34-62C
SLP98UH110XV60C
5137378
XP17-060-230 56,500 14.20 12.00 52,000 36,200 3.28 2.38 8.50 CX34-62C
3840336
XP17-060-230 56,000 14.20 12.00 51,000 36,200 3.26 2.40 8.50 CX34-62D
EL195UH135XE60D
4693671
XP17-060-230 56,000 14.70 12.20 51,000 35,800 3.24 2.40 8.50 CX34-62D
EL296UH135XV60D
5054841
XP17-060-230 56,000 14.70 12.00 51,500 35,800 3.28 2.42 8.70 CX34-62D
ML180UH135E60D
4666929
XP17-060-230 56,000 15.00 12.50 51,000 35,400 3.30 2.44 8.70 CX34-62D
SL280UH135V60D
3894881
XP17-060-230 56,000 14.70 12.20 51,000 35,800 3.24 2.40 8.50 CX34-62D
SLP98UH135XV60D
5136951
XP17-060-230 56,000 14.20 11.70 52,000 36,200 3.22 2.36 8.50 CX34-62D
3840345
NOTES:
Ratings are AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines);
• Cooling Ratings - 95°F outdoor air temperature and 80 °F db/67° F wb entering indoor coil air.
• High Temperature Heating Ratings - 47° F db/43° F wb outdoor air temperature and 70 °F db entering indoor coil air.
• Low Temperature Heating Ratings - 17 °F db/15° F wb outdoor air temperature and 70 °F db entering indoor coil air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed Furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (
58M81
) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see TXV Substitution Table at the beginning of the Heat Pump AHRI System Matches section.
When used with gas furnaces, a dual-fuel control, a control system with dual-fuel capabilities (LZP-2 or LZP-4), or a thermostat with dual-fuel capabilities must be used
(order separately).
To convert HSPF from Region IV to Region V - Divide by 1.15.