FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY

RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.   

This appliance has a pilot which must be lit with a piezo spark 
igniter. When lighting the pilot, follow these instructions exactly.

B.  

 BEFORE OPERATING smell all around the heater area for gas. Be 

sure to smell next to the floor because some gas is heavier than 
air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

 

• Do not try to light any appliance.

 

•  Do not touch any electric switch; do not use any phone in your 

building.

 

•  Immediately call your gas supplier from a neighbor’s phone. 

 

 

Follow the gas supplier’s instructions.

 

•   If you cannot reach your gas supplier, call the fire 

department.

C.  

Use only your hand to push in or turn the gas control knob.

 

 Never use tools. If the knob will not push in or turn by hand, do 

not try to repair it, call a qualified service technician. Forced or 

attempted repair may result in a fire or explosion.

D.   Do not use this heater if any part has been under water.

 

 Immediately call a qualified service technician to inspect the 

appliance and to replace any part of the control system and any 

gas control which has been under water.

LIGHTING INSTRUCTIONS

1. Stop! Read the safety information above.

2. Make sure manual shut-off valve is fully open.

3. Depress control knob in and turn clockwise                     to the

“OFF” position

 (Figure 10).

4. Wait 5 minutes to clear out any gas. Then smell for gas, including 

near the floor. If you smell gas, STOP! Follow the safety instructions 

in “What to do if you smell gas” under Section ‘B’ above. If you do not 

smell gas, go to next step.

5. The pilot is located on the left side behind the burner 

(Figure 11)

. The 

control knob is located on the lower right hand side of the outer case. It 

is marked as shown in 

Figure 10.

6. Depress control knob in and turn counterclockwise                      to 

the “SPARK” position 

(Figure 10)

 and hold there for a few seconds.

Note: If you are running the heater for the first time or after an extended 

period of non use it will be necessary to press the control knob all the 

way in for 30 seconds to allow air to bleed out of the gas piping.

7. Continue turning counterclockwise                        through the spark 
click to the PILOT light position, ensuring the pilot has lit. If not, turn the 
knob fully clockwise,                  and repeat.

8. Hold the control knob in for a further 10 seconds to prevent the flame 
failure detector from shutting off the gas while the probe is warming up.

9. Release the control knob while turning counterclockwise                                
to the preferred setting. 

• If the knob does not pop out when released, stop and immediately call 
your service technician or gas supplier.

• If the pilot will not stay lit after several tries, depress and turn the gas 
control knob clockwise                      to “OFF” and wait 30 seconds. 
Depress and turn knob counterclockwise                       to “SPARK” and 
ignite the heater again. If your pilot does not relight depress and turn 
control knob clockwise                      to “OFF” and call your service 
technician or gas supplier.

10. Wait 30 seconds before readjusting the heater when the control knob 
has been turned down to a lower setting.

TO TURN OFF GAS TO APPLIANCE

LIGHTING INSTRUCTIONS & TURNING OFF APPLIANCE

Depress and turn control knob clockwise                      to the “OFF” position 

(Figure 10)

. Close  the control access panel.

Figure 11:

 Pilot assembly . This is located 

behind the burner, on the left-hand side of 

the appliance .

The control knob is located on the lower 

right hand side of the outer case . It is 

marked as shown in 

Figure 10

 .

‘OFF’ position

‘SPARK’ position

‘LOW’ position

‘HIGH’ position

Figure 10

Figure 11

Содержание X-FIRES 1000-LP

Страница 1: ...uc tions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualifiedinstaller serviceagencyorthegassupplier WARNING If the information in t...

Страница 2: ...years of dependable and enjoyable service from your fireplace Safety and Your Fireplace 2 3 Important Safety Information 4 Appliance Installation Service and Maintenance Notices 5 Appliance Operation...

Страница 3: ...importantes relatives la s curit Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el contacto directo con e...

Страница 4: ...vec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cette...

Страница 5: ...pliance is Not convertible for use with other gases These appliances are designed to operate on natural gas or propane gas only The use of other fuels or combinations of fuels will degrade the perform...

Страница 6: ...reshowninBTUperhourandareforelevations up to 4 500 feet Do not install this heater at an elevation above 4 500 feet if the gas supply has not been derated for thatelevation Consultyourlocalgassupplier...

Страница 7: ...ies Inc to ANSI Z21 11 2 standard Massachusetts Requirements These fireplaces are approved for installation in the US state of Mas sachusetts if the following additional requirements are met Unvented...

Страница 8: ...___ volume of space ft3 50 ft3 Maximum BTU Hr the space can support Example 3072 ft3 50 ft3 61 44 or 61 440 BTU Hr the space can support 3 Add the BTU Hr of all the fuel burning appliances in the spac...

Страница 9: ...above the appliance It should be established that any mirrors or picture frames etc to be positioned on the wall above the appliance are able to withstand prolonged exposure to moderate heat and moist...

Страница 10: ...tested for soundness before any protection is applied and or the pipe work and fittings are buried 1 Remove the Grill Note This design of grill not fitted to widescreen model 2 Remove retaining wing...

Страница 11: ...g clearances must be maintained at all times Failure to do so may result in the risk of a fire For full information refer to the instruction manual provided with the heater Note Zero clearance from bo...

Страница 12: ...wall and drill holes for the additional fixing points as required Insert either wall plugs or cavity screw fixings as required Re position the outer casing on the wall and using a bubble level to chec...

Страница 13: ...the fireplace cavity when rigid pipe is used Ensure that a sediment trap is installed upstream of the heater Figure 6 within the structure s piping system to prevent moisture and contaminants from pa...

Страница 14: ...nd that extra ventilation may be needed during this time Advise to user to never place any objects on top of the appliance or obstruction this area in any way A periodic visual check of the pilot flam...

Страница 15: ...s are approved for use to clean glass Non ammonia based household cleaner 50 50 mix of white vinegar and water Gas fireplace stove glass cleaner PAINTED AREAS These can be cleaned using a dry cloth LI...

Страница 16: ...express both gas concentrations in terms of per centage To convert from parts per million ppm to a percentage divide the ppm figure by 10 000 Examples 35ppm 0 0035 15ppm 0 0015 5ppm 0 0005 Now divide...

Страница 17: ...pilot is located on the left side behind the burner Figure 11 The control knob is located on the lower right hand side of the outer case It is marked as shown in Figure 10 6 Depress control knob in a...

Страница 18: ...m with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY...

Страница 19: ...or 20 ADVERTENCIA ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES F860487 ISSUE A PRW POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL COLOQUE EL NIVEL SOBRE ESTE BORDE PARA...

Страница 20: ...s heater may result in property damage or personal injury Figure 13 4 off burner installation positions Figure 12 Glass Door Removal Remove the four 4 screws indicated then lift door off Visual check...

Страница 21: ...6 11 1 4 25 1 4 21 3 16 15 3 4 23 3 4 7 1 2 21 7 16 4 1 2 39 7 16 11 1 4 25 1 4 21 3 16 15 3 4 23 3 4 7 1 2 2 4 1 2 Surround Specifications Product Reference Information Cat No Model Ship Wt Ship Volu...

Страница 22: ...to rear entry point D2 Distance from mounting surface to center of side entry point D3 Distance from mounting surface to regulator gas entry point D3 D1 D2 REGULATOR GAS ENTRY POINT D1 D3 D2 Finished...

Страница 23: ...23 NOTES...

Страница 24: ...red through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the app...

Отзывы: