background image

10

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

Non-concealed gas connections may be made using the 

entry points at either end of the firebox or the one in 

the bottom of the firebox . A concealed gas connection 

may be made using the knock out hole in the center 

back of the firebox . Select the most appropriate entry 

point and knock out the rel evant hole in both the firebox 

and the outer casing .

No more than 59" of 1/4" diameter pipe must be used 

to avoid unnecessary pressure drops .

If a concealed gas con nection is to be made, the supply 

pipe should always be sleeved through walls and floors 

using the shortest possi ble route . 

For concealed supply pipe routing, pipes must (where 

possible) be ver tical and providing there is sufficient 

wall thick ness available, they should be placed in pipe 

chases . Horizontal pipe runs should be avoided where 

possible .  Prior to chasing a solid wall, an inspection 

should be made to note the proximity of any cables/

sockets outlets which may already be buried . Pipes 

must  be  secured  using  suitable  clips  and  protected 

against  corrosion .  Ideally  factory  finished  protected 

pipe-work and fittings should be used . Joints should 

be kept to a minimum and compression fittings must 

not be used . The pipe-work installation must be tested 

for soundness before any protection is applied and/or 

the pipe-work and fittings are buried .

1. Remove the Grill.

Note: This design of grill

not fitted to widescreen

model

2. Remove retaining 

wing nuts

3. Remove

spindle

retaining pin

4. Remove control indicator bracket and control knob

Note : X-Fire 1000

shown as example

5. Widescreen

models : Remove

two self-tapping

screws from the

Left hand side of

the outer casing

and one from the

right hand side.

Figure 2

PREPARING THE APPLIANCE

IMPORTANT NOTE: All gas piping must be done by a 

licensed plumber or gas fitter and must conform to 

the requirements of the National Fuel Gas Code NFPA 

54 / ANSI Z223.1 - latest edition.

1 . Remove the two retaining screws on each side of 

the upper grill and remove the grill from the outer 

casing .

2 . Remove the two retaining wing nuts from the retaining 

studs that protrude into the lower part of the main 

firebox as shown . The control knob is located on 

the lower right hand side of the outer casing, and 

is  mounted  in  an  indicator  bracket,  which  has  a 

metallic indication ‘pip’ (indication mark for proper 

knob alignment) . Both the knob and the indicator 

bracket should be removed as follows;

3 . Remove the retaining pin from the gas valve spindle 

and withdraw the control knob and the spindle exten-

sion from the right hand side of the appliance .

4 . Remove the four retaining screws and the indicator 

bracket . The firebox may now be detached from the 

outer casing .

1. Remove the Grill.

Содержание X-FIRES 1000-LP

Страница 1: ...uc tions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualifiedinstaller serviceagencyorthegassupplier WARNING If the information in t...

Страница 2: ...years of dependable and enjoyable service from your fireplace Safety and Your Fireplace 2 3 Important Safety Information 4 Appliance Installation Service and Maintenance Notices 5 Appliance Operation...

Страница 3: ...importantes relatives la s curit Page 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el contacto directo con e...

Страница 4: ...vec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cette...

Страница 5: ...pliance is Not convertible for use with other gases These appliances are designed to operate on natural gas or propane gas only The use of other fuels or combinations of fuels will degrade the perform...

Страница 6: ...reshowninBTUperhourandareforelevations up to 4 500 feet Do not install this heater at an elevation above 4 500 feet if the gas supply has not been derated for thatelevation Consultyourlocalgassupplier...

Страница 7: ...ies Inc to ANSI Z21 11 2 standard Massachusetts Requirements These fireplaces are approved for installation in the US state of Mas sachusetts if the following additional requirements are met Unvented...

Страница 8: ...___ volume of space ft3 50 ft3 Maximum BTU Hr the space can support Example 3072 ft3 50 ft3 61 44 or 61 440 BTU Hr the space can support 3 Add the BTU Hr of all the fuel burning appliances in the spac...

Страница 9: ...above the appliance It should be established that any mirrors or picture frames etc to be positioned on the wall above the appliance are able to withstand prolonged exposure to moderate heat and moist...

Страница 10: ...tested for soundness before any protection is applied and or the pipe work and fittings are buried 1 Remove the Grill Note This design of grill not fitted to widescreen model 2 Remove retaining wing...

Страница 11: ...g clearances must be maintained at all times Failure to do so may result in the risk of a fire For full information refer to the instruction manual provided with the heater Note Zero clearance from bo...

Страница 12: ...wall and drill holes for the additional fixing points as required Insert either wall plugs or cavity screw fixings as required Re position the outer casing on the wall and using a bubble level to chec...

Страница 13: ...the fireplace cavity when rigid pipe is used Ensure that a sediment trap is installed upstream of the heater Figure 6 within the structure s piping system to prevent moisture and contaminants from pa...

Страница 14: ...nd that extra ventilation may be needed during this time Advise to user to never place any objects on top of the appliance or obstruction this area in any way A periodic visual check of the pilot flam...

Страница 15: ...s are approved for use to clean glass Non ammonia based household cleaner 50 50 mix of white vinegar and water Gas fireplace stove glass cleaner PAINTED AREAS These can be cleaned using a dry cloth LI...

Страница 16: ...express both gas concentrations in terms of per centage To convert from parts per million ppm to a percentage divide the ppm figure by 10 000 Examples 35ppm 0 0035 15ppm 0 0015 5ppm 0 0005 Now divide...

Страница 17: ...pilot is located on the left side behind the burner Figure 11 The control knob is located on the lower right hand side of the outer case It is marked as shown in Figure 10 6 Depress control knob in a...

Страница 18: ...m with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY...

Страница 19: ...or 20 ADVERTENCIA ESPACIO LIBRE HASTA MATERIALES COMBUSTIBLES F860487 ISSUE A PRW POSITION SPIRIT LEVEL ALONG THIS EDGE TO LEVEL TEMPLATE BEFORE MARKING OUT WALL COLOQUE EL NIVEL SOBRE ESTE BORDE PARA...

Страница 20: ...s heater may result in property damage or personal injury Figure 13 4 off burner installation positions Figure 12 Glass Door Removal Remove the four 4 screws indicated then lift door off Visual check...

Страница 21: ...6 11 1 4 25 1 4 21 3 16 15 3 4 23 3 4 7 1 2 21 7 16 4 1 2 39 7 16 11 1 4 25 1 4 21 3 16 15 3 4 23 3 4 7 1 2 2 4 1 2 Surround Specifications Product Reference Information Cat No Model Ship Wt Ship Volu...

Страница 22: ...to rear entry point D2 Distance from mounting surface to center of side entry point D3 Distance from mounting surface to regulator gas entry point D3 D1 D2 REGULATOR GAS ENTRY POINT D1 D3 D2 Finished...

Страница 23: ...23 NOTES...

Страница 24: ...red through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the app...

Отзывы: