NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Non-concealed gas connections may be made using the
entry points at either end of the firebox or the one in
the bottom of the firebox . A concealed gas connection
may be made using the knock out hole in the center
back of the firebox . Select the most appropriate entry
point and knock out the rel evant hole in both the firebox
and the outer casing .
No more than 59" of 1/4" diameter pipe must be used
to avoid unnecessary pressure drops .
If a concealed gas con nection is to be made, the supply
pipe should always be sleeved through walls and floors
using the shortest possi ble route .
For concealed supply pipe routing, pipes must (where
possible) be ver tical and providing there is sufficient
wall thick ness available, they should be placed in pipe
chases . Horizontal pipe runs should be avoided where
possible . Prior to chasing a solid wall, an inspection
should be made to note the proximity of any cables/
sockets outlets which may already be buried . Pipes
must be secured using suitable clips and protected
against corrosion . Ideally factory finished protected
pipe-work and fittings should be used . Joints should
be kept to a minimum and compression fittings must
not be used . The pipe-work installation must be tested
for soundness before any protection is applied and/or
the pipe-work and fittings are buried .
1. Remove the Grill.
Note: This design of grill
not fitted to widescreen
model
2. Remove retaining
wing nuts
3. Remove
spindle
retaining pin
4. Remove control indicator bracket and control knob
Note : X-Fire 1000
shown as example
5. Widescreen
models : Remove
two self-tapping
screws from the
Left hand side of
the outer casing
and one from the
right hand side.
Figure 2
PREPARING THE APPLIANCE
IMPORTANT NOTE: All gas piping must be done by a
licensed plumber or gas fitter and must conform to
the requirements of the National Fuel Gas Code NFPA
54 / ANSI Z223.1 - latest edition.
1 . Remove the two retaining screws on each side of
the upper grill and remove the grill from the outer
casing .
2 . Remove the two retaining wing nuts from the retaining
studs that protrude into the lower part of the main
firebox as shown . The control knob is located on
the lower right hand side of the outer casing, and
is mounted in an indicator bracket, which has a
metallic indication ‘pip’ (indication mark for proper
knob alignment) . Both the knob and the indicator
bracket should be removed as follows;
3 . Remove the retaining pin from the gas valve spindle
and withdraw the control knob and the spindle exten-