TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM

sYMptoM

possiBLe causes

correctiVe action

Check voltage on AC terminals of module an/or batteries.  The value should be 

around 2.7 to 3.2 VAC.  Confirm that wire connections are secure.

Check for visible cracked casing, cuts, etc.

Check pilot assembly for visibly broken spark electrode, etc. 

Check voltage on D.C. terminal of batteries.  The value should be around 3.0V

Ensure that the gas supply is turned on.

Ensure sensor wire connection is secure. 

Ensure black, green and orange wires connection is secure to valve.

Ensure black sensor wire (S) and black igniter wire (I) is secure to ignition 

module.

Purge gas line of air.

Test voltage at AC terminals of module and/or batteries.  It should be around 

2.7 to 3.2 VAC.

Turned gas supply to "ON".

Check wire connection. 

Check location of sensor.

Check vent system for obstructions.

Check for proper log placement.

Check for proper air shutter openings.

a.

  Low voltage/or bad lead 

wires.

B.

  Damaged igniter wire.

c.

  Damaged pilot assembly.

d.

  Batteries Low

a.

  No fuel supply.

B.

  Loose sensor wire.

c.

  Lose wires to valve.

d.

  Loose wires to ignition 

module.

e.

  Air in the gas line.

F.

  Low voltage.

a.

  Gas supply is turned 

"OFF".

B.

  Loose wire connection on 

valve or ignition module.

c.

  Flame does not engulf 

flame sensor.

d.

  Obstructed vent system.

a.

  Flame impingement on 

the  log.

B.

  Improper air shutter 

opening.

1.

  Nothing happens when 

ON/OFF switch is turned 

on (pilot does not spark).

2.

  The main burner does 

not light and the igniter 

is sparking.

3.

  The main burner come 

"ON" but then go "OFF".

4. 

 The log and glass soot.

Note:

  Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall 

switch are in the “ON” position.

Important:

 Valve system troubleshooting should only be accomplished by a qualified service technician.

Содержание SLDVT-35

Страница 1: ...of this appliance will be hot during operation and will retain heat forawhileaftershuttingofftheappli ance Severe burns may result Carefully supervise children in the same room as appliance If small c...

Страница 2: ...ge 13 Lighting Instructions Millivolt Page 16 Lighting Instructions Electronic Page 18 Maintenance Schedule Page 20 Troubleshooting Guide Millivolt Page 21 Troubleshooting Guide Electronic Page 22 Rep...

Страница 3: ...e side and then the other so the tabs clear both of the locating holes On millivolt systems the piezo igniter HI LO flame adjustment knob and pilot and main gas OFF ON control knob are located below t...

Страница 4: ...ce lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve Ifyourelectronicapplianceisequippedwithan optionalremotewallswitchorremotecontr...

Страница 5: ...d Sooting on Page 10 The Homeowner must contact a qualified service technician at once if any abnormal condition is observed Small Area Paint Touch up The finish of the appliance is a high qual ity po...

Страница 6: ...see Figure 5 1 To access the glass door securing latches firstopenthelowercontrolcompartmentdoor Figure 5 by lifting and pulling the bottom panel forward 2 Pull the latches forward and down to release...

Страница 7: ...herightfrontlog 3 asshown Posi tion it on the two right front log brackets 4 Placetheleftrearlog 4 asshown Position it on the left rear log bracket 5 Place the right rear log 5 as shown Posi tion it o...

Страница 8: ...er for the entire log set H7244 Step 2 Step 3 Step 4 3 Left Rear Bracket Step 1 Align hole at the bottom of left front log 1 over the left front bracket and the right front log over the right front br...

Страница 9: ...ottom of left front log 2 over the left front bracket and the right front log over the right front bracket Step 3 Align the hole at the bottom of log 5 over the Nub of log 3 as shown Step 4 5 Step 1 S...

Страница 10: ...reminutestoensurethattheflamenormal izes and the flames do not appear sooty The following chart is provided to aid you in achieving the correct air shutter adjustment for your installation Air Shutter...

Страница 11: ...rfireplace Please contact your Lennox dealer for any questions or concerns For the number of your nearest Lennox dealer please call 1 800 9 LENNOX Replacement parts A complete parts list is found at t...

Страница 12: ...BOX W GR BK 120 VAC BK R TRANSFORMER 3V INTERMITTENT ELECTRONIC WIRING DIAGRAM BROWN BROWN BLACK BATTERY BACK UP TO WALL SWITCH FRS OR THERMOSTAT BLACK SENSOR BLACK IGNITOR SPARK TO PILOT IGNITOR IGNI...

Страница 13: ...the transmitter When a button on the transmitter is pressed a signal light illuminates briefly to verify that a signal has been sent The Model RCL is designed to operate with all mil livolt ignition...

Страница 14: ...DESIGN KITS Cat No Model Description Model Series 35 Arch Pane Door Charcoal 35 Arch Pane Door Satin Pewter SLDVT 35 H6106 APDML35C H6107 APDML35SP 40 Arch Pane Door Charcoal SLDVT 40 40 Arch Pane Do...

Страница 15: ...rick Liner Kit Top Rear SLDVT 35 H0914 MBLK 40 Brick Liner Kit Top Rear SLDVT 40 Brickaded Panel Liner Kit The brickaded liner kits include ceramic panels as shown here The panels have brick like feat...

Страница 16: ...p Pilot should remain lit If it goes out repeat steps 5 through 8 If knob does not pop up when released stop and immediately call your service technician or gas supplier If pilot will not stay lit aft...

Страница 17: ...celle en poussant le bouton jusqu ce que la veilleuse s enflamme Continuez de tenir le bouton de r glage enfonc pen dant environ 90 secondes apr s l allumage de la veilleuse Rel chez le bouton et il s...

Страница 18: ...mation above on this page 2 Turn remote wall switch to OFF or set wall thermostat to lowest setting If used remove the batteries from the battery holder 3 This appliance is equipped with an ignition d...

Страница 19: ...ur mural la position d arr t OFF 3 Ouvrez la porte du compartiment de contr le du bas 4 Assurez vousquelasoupaped arr tdelacanalisationprincipale est ouverte 5 Tournez la manette de r glage du gaz la...

Страница 20: ...rior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the ap...

Страница 21: ...e switch is used for burner operation if the standard burner OFF ON switch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or rem...

Страница 22: ...wire connection Check location of sensor Check vent system for obstructions Check for proper log placement Check for proper air shutter openings A Low voltage or bad lead wires B Damaged igniter wire...

Страница 23: ...ecorative Volcanic Stone 80L42 1 80L42 1 9 Orifice Holder H7257 1 H7257 1 10 Gas Line Flexible Connector 93L32 1 93L32 1 Gas Controls SIT Millivolt Item No Description Natural Gas Propane Gas Part No...

Страница 24: ...time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information LHP 1110 West Taft Avenue...

Отзывы: