NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE

SAFETY / LISTING LABEL

MINIMUM CLEARANCES TO COMBUSTIBLES -   SHR40/SHR33

E = Top Facing to Bottom of Insert

35”

F = Center of Fireplace to Side Facing or Side Wall

30”

*J = 12” Mantel to Bottom of Insert

38”

* See owner’s manual for additional mantel clearances and options

MINIMUM FIREPLACE SIZES REQUIRED

A = 36.00” Front Opening

B = 21.50” Height

C = 19.50” Rear Width

D = 16.00” Fireplace Depth

HEARTH PROTECTION

G = Minimum Hearth Protection

G =

 from Front of Insert

H = Vertical Distance from Insert

H =

 Bottom to Combustible Material

Note: Hearth protection to be min. 1” thick non-combustible or equivalent, with a k factor of .84.

MODEL

MODÈLE

SHR 40

MANUFACTURED BY / FABRIQUÉ PAR:

LENNOX HEARTH PRODUCTS

PO BOX 987

AUBURN, WA., USA 98071

SHR

SERIAL

 NO.

Report No. / Número de Rapport

 050-F-22-5

H

MINIMUM

CLEARANCES

CL

J

F

E

G

MANTEL

TRIM

LISTED VENTED GAS FIREPLACE HEATER - FIREPLACE INSERT - NOT FOR USE WITH SOLID FUEL

TESTED TO ANSI Z21.88-2005/CSA 2.33-2005 “VENTED GAS FIREPLACE HEATERS”, UL307b, CSA P.4.1-02, AND CGA 2.17-M91.

THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY.  IF NOT, FOLLOW THE CURRENT ANSI 

Z223.1/NFPA 54-LATEST EDITION (USA) OR CAN/CGA  B149.1-LATEST EDITION (CANADA). THIS APPLIANCE MUST BE INSTALLED 

IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION INSTRUCTION. FOR INSTALLATION IN SOLID FUEL BURNING 

FIREPLACES ONLY - MASONRY OR FACTORY BUILT.  THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS. 

THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN AN 

AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME WHERE NOT PROHIBITED BY LOCAL CODES. SEE 

OWNER’S MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED 

KIT IS USED.

DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.

IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY. 

IF NOT, FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USA) OR CSA C22-1-LATEST 

EDITION (CANADA).

CHIMNEY - USE 3” DIAMETER SINGLEWALL OR FLEX GAS VENT CHIMNEY OR LINER LISTED TO UL1777.

THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN ACCORDANCE WITH THE MANUFACTURER’S 

INSTALLATION INSTRUCTIONS.

FOR ALTITUDES ABOVE 2,000 FT/610M (IN CANADA 4500 FT/1370M) DE-RATE THE APPLIANCE BY FOUR (4)% FOR EVERY 

1,000 FT (405 M).

CAUTION:

HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP 

CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS 

AWAY. KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING 

INSTRUCTIONS ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS 

APPLIANCE ONLY. DO NOT OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. 

REPLACEMENT OF THE PANEL(S) SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN 

CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED 

WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED 

INSTALLER, SERVICE AGENCY OR GAS SUPPLIER.

DO NOT REMOVE OR COVER THIS LABEL

Part No./ No. pièce #36256 Rev. A, 12/06

FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.

CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL. SI L’ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT 

CETTE ÉTIQUETTE, C’EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.

DÉGAGEMENTS AUX COMBUSTIBLES -  SHR40/SHR33

E = Dessus du foyer à partir de la base

35”

F = Mur latéral à partir du centre du foyer

30”

*J = 12” manteau de foyer à partir de la base

38”

* Voir le manuel d’entretien pour les informatinos supplémentaires reliées

   aux distances à respecter pour le manteau de foyer

DIMENSIONS MINIMUMS DE FOYER REQUISES

A = 36.00” Ouverture avant

B = 21.50” Hauteur

C = 19.50” Largeur arrière

D = 16.00” Profondeur du foyer

PROTECTION DU FOYER

G = Extension d’âtre min. devant

G =

 le foyer

H = Distance verticale de la base de

H =

 l’appareil aux combustibles

Note: Extension d’âtre fabriqué avec 1” minimum de matériaux non-combustible ou équivalent possédant un facteur k de 0.84.

H

DÉGAGEMENTS

MINIMUMS

CL

J

F

E

G

MANTEAU

DE FOYER

PIÈCE DE 

FINITION

HOMOLOGUÉ FOYER RADIANT PRÉFABRIQUÉ AU GAZ - INSERTION DE FOYER AU GAZ - NE PAS 

UTILISER AVEC DU COMBUSTIBLE SOLIDE

TESTÉ SELON LA NORME ANSI Z21.88-2005/CSA 2.33-2005 «FOYER RADIANT AU GAZ», UL307B, CSA P.4.1-02, ET CGA 2.17-M91.

CET APPAREIL DOIT ÊTRE INSTALLÉ CONFORMÉMENT AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION 

ANSI NFPA 54-DERNIÈRE ÉDITION (ETATS-UNIS), OU CAN/CGA-B149.1-DERNIÈRE ÉDITION (CANADA). CET APPAREIL DOIT ÊTRE 

INSTALLÉ SELON LES DIRECTIVES D’INSTALLATION DU FABRICANT. POUR INSTALLATION DANS DES FOYERS À COMBUSTIBLE 

SOLIDE SEULEMENT - DE MAÇONNERIE OU PRÉFABRIQUÉ EN USINE. CE FOYER RADIANT AU GAZ À ÉVACUATION N’EST PAS 

CONÇU POUR ÊTRE UTILISÉ AVEC DES FILTRES À AIR.

CET APPAREIL DOIT ÊTRE UTILISÉ AVEC LE TYPE DE GAZ INDIQUÉ SUR LA PLAQUE SIGNALÉTIQUE ET PEUT ÊTRE INSTALLÉ 

DANS UNE MAISON PRÉUSINÉE OU DANS UNE MAISON MOBILE FIXE, LÀ OÙ LES CODES RÉGIONAUX LE PERMETTENT. VOIR LE 

MANUEL D’ENTRETIEN POUR PLUS DE DÉTAILS. CET APPAREIL NE PEUT PAS ÊTRE CONVERTI POUR L’USAGE AVEC D’AUTRES 

TYPES DE GAZ À MOINS D’UTILISER UNE TROUSSE DE CONVERSION HOMOLOGUÉE.

DANGER: RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHEZ L’APPAREIL AVANT D’EN FAIRE L’ENTRETIEN.

SI L’APPAREIL REQUIERT UN BRANCHEMENT ÉLETRIQUE, LES RACCORDEMENTS ET LA MISE À LA TERRE DOIVENT ÉTRE 

CONFORMES AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI/NFPA 70 OU CSA C22-1.

CHEMINÉE - UTILISER UN CONDUIT D’ÉVACUATION 3” DE DIAMÈTRE RIDIGE OU FLEXIBLE HOMOLOGUÉ UL 1777.

CET APPAREIL DOIT ÊTRE RELIÉ À UN SYSTÈME D’ÉVACUATION TEL QUE SPÉCIFIÉ DANS LE MANUEL D’INSTALLATION DU 

FABRICANT.

EN ALTITUDE, AU-DELÀ DE 2000 PI/610 M, (AU CANADA 0-4500 PI/0-1370M) LA CAPACITÉ ÉNERGÉTIQUE DE L’APPAREIL 

DIMINUE DE QUATRE (4)% POUR CHAQUE 1000 PI (405 M).

DANGER:

 CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE INSTALLÉ À L’ÉCART DES 

ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET RIDEAUX. SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS 

LA PIÈCE. GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES 

VAPEURS ET LIQUIDES INFLAMMABLES. MAINTENEZ LE BRÛLEUR ET LE BOÎTIER DES COMMANDES PROPRE EN TOUT 

TEMPS. VOIR LES MANUELS D’INSTALLATION ET D’ENTRETIEN QUI ACCOMPAGNENT L’APPAREIL. SEUL LE PANNEAU 

VITRÉ FOURNI PAR LE MANUFACTURIER PEUT ÊTRE UTILISÉ AVEC CET APPAREIL. EN AUCUN CAS, L’APPAREIL NE 

PEUT ÊTRE UTILISÉ SANS LA VITRE OU AVEC LA VITRE BRISÉE. LE REMPLACEMENT DE LA VITRE DOIT ÊTRE EFFECTUÉ 

PAR UN TECHNICIEN DE SERVICE QUALIFIÉ.
AVERTISSEMENT: UNE INSTALLATION INADÉQUATE DE MÊME QU’UN AJUSTEMENT, UNE MODIFICATION, UNE 

RÉPARATION OU UN ENTRETIEN INCORRECTS PEUVENT CAUSER DES BLESSURES OU DOMMAGES À LA PROPRIÉTÉ. 

RÉFÉREZ-VOUS AU MANUEL D’ENTRETIEN LIVRÉ AVEC CET APPAREIL. POUR DE L’ASSISTANCE, CONSULTEZ UN 

INSTALLATEUR QUALIFIÉ, UNE ENTREPRISE DE SERVICE OU UN FOURNISSEUR DE GAZ.

DATE OF MANUFACTURE / DATE DE FABRICATION

2007

2009

2010

2008

JANV

JAN

FEVR

FEB

MARS

MAR

AVR

APR

MAI

MAY

JUIN

JUN

JUIL

JUL

AOÛT

AUG

SEPT

SEP

OCT

OCT

NOV

NOV

DEC

DEC

IGN 06-2835

N’ENLEVEZ PAS OU NE COUVREZ PAS CETTE ÉTIQUETTE

SHR40/33

G

12”

0”

H

0”

8”

SHR40/33

G

12”

0”

H

0”

8”

SPÉCIFICATIONS

Modèle SHR40

Modèle SHR33

GAZ NATUREL

GAZ PROPANE

GAZ NATUREL

GAZ PROPANE

ENTRÉE MAX/MIN BTU/HR 0-4500 pi (0-1370 

M)*

40000/24000

37500/21500

33000/19500

33000/19500

PRESSION À LA SORTIE  (IN. WC/C.E.)

3,5

10,0

3,5

10,0

PRESSION MINIMUM D’ENTRÉE DU GAZ 

(IN. WC/C.E.)

5,0

10,5

5,0

10,5

ORIFICE (DMS) 0-4500 pi (0-1370 M)*

,125

#49

#36

#51

* L’APPAREIL PRÉUSINÉ EST MUNI D’ÉQUIPEMENT POUR 0-2000 PIEDS (0-610 M). AU CANADA 0-4500 PIEDS (0-1370M).

SPÉCIFICATIONS ÉLECTRIQUE 120 VCA, 60 HZ, MOINS DE 2 AMPÈRES 

RATINGS

Model SHR40

Model SHR33

NATURAL GAS

LP GAS

NATURAL GAS

LP GAS

MAX/MIN INPUT BTUH 0-2,000 FT (0-610 M)*

40,000/24,000

37,500/21,500

33,000/19,500

33,000/19,500

MANIFOLD PRESSURE (IN. WC)

3.5

10.0

3.5

10.0

MIN. INLET PRESSURE (IN. WC)

5.0

10.5

5.0

10.5

ORIFICE (DMS) 0-2,000 FT (0-610 M) *

.125

#49

#36

#51

*UNIT FACTORY EQUIPPED FOR 0-2000 FT/0-610 M, IN CANADA 0-4500 FT/0-1370 M

ELECTRICAL RATING: 120 VAC, 60 HZ, LESS THAN 2 AMPS

US

Portland

 2010    2011     2012    2013

Содержание SHRL 33 DV INS

Страница 1: ...uctions du fournis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindie L installation et l entretien doivent tre assur s par un installateur ou un service d entretie...

Страница 2: ...e 29 Replacement Parts List Page 30 Part Identification Page 31 Optional Accessories Page 36 Safety Listing Label Page 39 Lighting Instructions Label Page 40 Warranty and Product Reference Information...

Страница 3: ...ler service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to...

Страница 4: ...not be connected to a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance i...

Страница 5: ...nician if you decide to change orifices Theuseofotherfuelsorcombinationoffuelswilldegradetheperformance of this system and may be dangerous Orifice Size Altitude Adjustment These appliances are tested...

Страница 6: ...tallation requirements These appliances must be vented directly to the outside in accordance with the current edition of the National Fuel Gas Code NFPA 54 in U S A and CAN CSA B149 1 in Canada and mu...

Страница 7: ...centimeters in length The individual manual shut off must be a T handle type valve Massachusetts Horizontal Vent Requirements IntheCommonwealthofMassachusetts horizontalterminationsinstalled less tha...

Страница 8: ...Unit To Intake Collar 7 7 8 200 N O D Width Small 3 pc Flange 36 5 8 930 N O D Width Large 3 pc Flange 41 1041 O O D Height Small 3 pc Flange 25 7 8 657 O O D Height Large 3 pc Flange 28 711 P O D Wi...

Страница 9: ...rfaces to combustible construction etc above the appliance Paint or lacquer used to finish the mantel must be heat resistant in order to avoid discoloration Minimum Clearances to Combustibles Hearth F...

Страница 10: ...tible une fois la conduite de gaz en place IMPORTANT Wheninstallingtheseappliancesintoafactorybuiltfireplace or heat form the air flow within and around the fireplace shall not be altered by the insta...

Страница 11: ...ethod for achieving a positive flue connection between the vent and intake liners and the chimney Air Inlet Liner for combustion air When terminating the air inlet liner at this point a positive flue...

Страница 12: ...seal See Table 5 for the minimum vertical termination height requirements Vertical Termination Height Minimum Factory Built and Masonry Fireplaces The vent air intake termination clearances above the...

Страница 13: ...ocationsontheupperlatchassembly You can then tighten the screws down by turning the wrench or T Handle clockwise SNUG ONLY DO NOT OVERTIGHTEN See Figure 12 4 Figure 13 shows the insert with the door i...

Страница 14: ...refractory brick panels and log set theinsertshouldbeinstalledinthefireplace the venting attached the gas line connected and tested for leaks and the initial burner operation checked Figure 15 Figure...

Страница 15: ...of carbon monoxide CO a colorless orderless toxic gas The size and position of the log set is critical to achieve a safe reliable and attractive flame pattern Any attempt to use a different log set i...

Страница 16: ...ctory in front See Figure 24 C B F pin 5 Locate groove in center log B and place the top of the right log D in groove with the bottom end of the log resting against the right refractory panel See Figu...

Страница 17: ...of its final location Surround Kits Models SHR33 SHR40 Part Cat Description Dimensions 75387 Small 3 sided Flange 36 5 8 W x 25 7 8 H 75385 Small 4 sided Flange 36 5 8 W x 29 3 16 H 75388 Large 3 side...

Страница 18: ...in Picture C Turning the ball screw counter clockwise as you are look ing at it will give you less tension and turning the ball screw clockwise will give you more tension when opening and closing the...

Страница 19: ...ometer and check the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution and retighten if necessary If the pressure i...

Страница 20: ...thermostat mural voir Figure B et le cas ch ant sur le bo tier delat l commande FigureC Pouracheverl instal lationcorrectedecefoyer proc dezcommesuitavec les tiquettesadh sivesenlangues trang resfourn...

Страница 21: ...d call your service technician or your gas sup plier 8 After pilot is lit turn gas control counterclockwise to ON Knob can only be turned ON if the knob has popped out 9 To turn burner on turn ON OFF...

Страница 22: ...To Turn Off Gas To Appliance above Gas Control Knob Pilot On Off Flame Height Control Knob Hi Lo Piezo Igniter WARNINGS Improper installation adjustment alteration service or maintenance can cause inj...

Страница 23: ...ry while adjusting flame appearance Theairshuttershouldneverbesetsoastomake the tips of the flames sooty or create sooting on the viewing glass logs or heat exchanger If sootbeginstoformafterburning t...

Страница 24: ...t is used Fire the fireplace insert four suc cessive times for ten minutes each time with a five minute cool down between each firing to cure the paint and burn off lubricants used in the manufacturin...

Страница 25: ...manufacturers instructions could result in a malfunction Pay special attention to the thermostat location require ments If the location requirements are not adhered to the appliance erratic operation...

Страница 26: ...roperly size the flames The flames should directly contact the thermopile and extend across the main burner ports Be careful not to back the screw out of its threads Replace the cover and check for ga...

Страница 27: ...the inside of the glass this condensation and fog will usually disappear in a few minutes This can cause lint dust and other airborne particles to cling to the glass surface Initialcuringofthehightemp...

Страница 28: ...chnician Perform the appropriate appliance checkout procedure detailed in this manual Replacing Rockwool Ember Materials Homeowner Qualified Service Technician Remove old ember materials and vacuum th...

Страница 29: ...efective igniter no spark at electrode Defective or misaligned electrode at pilot spark at electrode Check gas supply To purge hold in gas cock on valve for 1 2 minutes and try again Check for spark a...

Страница 30: ...ector 26 H5751 Blower Ducting 27 H5752 Wire Grommets 28 H5753 Burner Support 29 H5754 Front Leveling leg Assembly 30 H5755 Gasket kit 31 H5756 Surround Hinge 32 H5757 Ball Screw Assembly 33 H5758 Ball...

Страница 31: ...26 25 27 2 30 PART IDENTIFICATION Item Description 2 Air Intake Assembly 3 Blower Box Assembly 4 Flue Collar Assembly 5 Blower Snap Switch Assembly 23 Brick Panel Brackets 24 Surround Hanging Brackets...

Страница 32: ...LE Item Description 8 Burner Assembly 9 Pilot Assembly w Shield 10 Main Orifice 11 Bulkhead Assembly 12 Cassette Plate Assembly 13 Valve Assembly 14 Air Shutter Assembly 15 Cassette Assembly 30 Gasket...

Страница 33: ...T TO SCALE 8 PART IDENTIFICATION Item Description 2 Air Intake Assembly 3 Blower Box Assembly w Blower 6 Rear Leveling Leg Assembly 7 Outer Bottom Assembly 8 Burner Assembly 27 Wire Grommets 29 Front...

Страница 34: ...N 22 Ceramic Log Set Item Description 8 Burner Assembly 16 Louver Assembly 17 Blower Rheostat 18 Control Panel Valve Cover 19 On Off Switch Item Description 20 Igniter w nut 21 Door Assembly 22 Cerami...

Страница 35: ...e Surround Assembly Item Description 31 Surround Flange Hinge 32 Ball Screw Assembly 33 Ball Screw Catch Assembly 34 Surround Spacer Kit Small 35 Surround Spacer Kit Large 36 Extrusion Kit 3 Piece Sma...

Страница 36: ...ng the hand held remote control transmitter Screen Panel Kit This screen panel kit can be installed over the glass enclosure panel to help protect from making direct contact with the hot glass surface...

Страница 37: ...piece Small 75388 SHR SP 3P LG Surround Panel Kits 3 piece Large Width Height Cat No Model Description H7987 SHR BRK STD Brick Panel Set Tan H7988 SHR BRK RED Brick Panel Set Red H7989 SHR BRK ARCHSTO...

Страница 38: ...er Kit DVI 3 X 35 requires 2 one for exhaust and one for intake TKDVI TKDVI Termination Kit DVI termination cap and flashing DV3FK35 DV3FK35 Flex Liner and Termination Kit 3 X 35 includes 2 flex liner...

Страница 39: ...devant G le foyer H Distance verticale de la base de H l appareil aux combustibles Note Extension d tre fabriqu avec 1 minimum de mat riaux non combustible ou quivalent poss dant un facteur k de 0 84...

Страница 40: ...ion suppl mentaires contactez un installateur qualifi un agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d vacuation vous pourr...

Страница 41: ...41 NOTES...

Страница 42: ...anufacturer Normally all parts should be ordered through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the follow...

Отзывы: