background image

36

NOTE: DIAGRAMS AND ILLUSTRATIONS ARE NOT TO SCALE

OPTIONAL ACCESSORIES

Standard Remote Control System

The  Model  RCL  (Standard)  Remote  Control 

System,  features  a  simple  On/Off  control 

function for the insert.  This model includes a 

hand-held transmitter, a remote receiver with 

wall-mount coverplate and all hardware required 

to install the unit.  The remote receiver can be 

wall or hearth mounted.

Cat. No. 

Model 

Description

H0249   

RCL  

Remote Control System  (Standard) 

Cat. No. 

Model 

Description

H0251 

RCL-T 

Remote Control System (Deluxe)

Deluxe Remote Control System 

The  Model  RCL-T  (Deluxe)  Remote  Control 

System  has all of the features of the standard 

system along with an added easy to read LCD 

screen which presents access to many enhance-

ments, including; battery power level indicator, 

timer, mode of operation, thermostatic display 

including  room  temperature  in  either  metric 

or  English  units,  flame  indicator  and  clock.  

Fully programmable, the Model RCL-T allows 

for command over nearly all operational and 

temperature  variables,  using  the  hand  held 

remote control transmitter.

Screen Panel Kit

This screen panel kit can be installed over the glass enclosure panel  to 

help protect from making direct contact with the hot glass surface. 

Cat. No. 

Model 

Description

75392 

SHR-GS-BLK 

Glass Screen Panel Kit, Black

Wall Thermostat

The  wall  thermostat  kit  provides  temperature  control  for  optimum 

comfort.

Touch-Up Paint Kit 

Repair of minor scratches and discoloration of the appliance's black painted 

surfaces may be accomplished with the use of this touch-up paint kit.

Cat. No. 

Model 

Description 

70K99 

TSPK-B 

Touch-Up Paint Kit, Black   

PA I N T

Fuel Conversion Kits

Converting  your  Shoreline™  gas  insert  between  natural  gas  (40,000-

33,000  BTU’s)  and  LP  (37,500-33,000  BTU’s)  or  vice  versa  can  be 

accomplished  by  installing  a  conversion  kit  (valve  regulator  for  fuel 

conversion and burner orifice). Only a qualified service technician should 

perform the conversion.

Cat. No.  Model 

Description 

75390

 

SHR-CK-NG to LP

  Natural Gas to Propane Conversion Kit

75393

 

SHR-CK-LP to NG

  Propane to Natural Gas Conversion Kit

Cat. No. 

Model 

Description

H4635     

DWTK    

Wall Thermostat Kit, Digital

(ref. Form # 750,129M)

(ref. Form # 750,127M)

(ref. Form # 750,241M-to LP, & 750,243M-to NG)

(ref. Form # 775,234M)

Содержание SHRL 33 DV INS

Страница 1: ...uctions du fournis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindie L installation et l entretien doivent tre assur s par un installateur ou un service d entretie...

Страница 2: ...e 29 Replacement Parts List Page 30 Part Identification Page 31 Optional Accessories Page 36 Safety Listing Label Page 39 Lighting Instructions Label Page 40 Warranty and Product Reference Information...

Страница 3: ...ler service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change to...

Страница 4: ...not be connected to a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance i...

Страница 5: ...nician if you decide to change orifices Theuseofotherfuelsorcombinationoffuelswilldegradetheperformance of this system and may be dangerous Orifice Size Altitude Adjustment These appliances are tested...

Страница 6: ...tallation requirements These appliances must be vented directly to the outside in accordance with the current edition of the National Fuel Gas Code NFPA 54 in U S A and CAN CSA B149 1 in Canada and mu...

Страница 7: ...centimeters in length The individual manual shut off must be a T handle type valve Massachusetts Horizontal Vent Requirements IntheCommonwealthofMassachusetts horizontalterminationsinstalled less tha...

Страница 8: ...Unit To Intake Collar 7 7 8 200 N O D Width Small 3 pc Flange 36 5 8 930 N O D Width Large 3 pc Flange 41 1041 O O D Height Small 3 pc Flange 25 7 8 657 O O D Height Large 3 pc Flange 28 711 P O D Wi...

Страница 9: ...rfaces to combustible construction etc above the appliance Paint or lacquer used to finish the mantel must be heat resistant in order to avoid discoloration Minimum Clearances to Combustibles Hearth F...

Страница 10: ...tible une fois la conduite de gaz en place IMPORTANT Wheninstallingtheseappliancesintoafactorybuiltfireplace or heat form the air flow within and around the fireplace shall not be altered by the insta...

Страница 11: ...ethod for achieving a positive flue connection between the vent and intake liners and the chimney Air Inlet Liner for combustion air When terminating the air inlet liner at this point a positive flue...

Страница 12: ...seal See Table 5 for the minimum vertical termination height requirements Vertical Termination Height Minimum Factory Built and Masonry Fireplaces The vent air intake termination clearances above the...

Страница 13: ...ocationsontheupperlatchassembly You can then tighten the screws down by turning the wrench or T Handle clockwise SNUG ONLY DO NOT OVERTIGHTEN See Figure 12 4 Figure 13 shows the insert with the door i...

Страница 14: ...refractory brick panels and log set theinsertshouldbeinstalledinthefireplace the venting attached the gas line connected and tested for leaks and the initial burner operation checked Figure 15 Figure...

Страница 15: ...of carbon monoxide CO a colorless orderless toxic gas The size and position of the log set is critical to achieve a safe reliable and attractive flame pattern Any attempt to use a different log set i...

Страница 16: ...ctory in front See Figure 24 C B F pin 5 Locate groove in center log B and place the top of the right log D in groove with the bottom end of the log resting against the right refractory panel See Figu...

Страница 17: ...of its final location Surround Kits Models SHR33 SHR40 Part Cat Description Dimensions 75387 Small 3 sided Flange 36 5 8 W x 25 7 8 H 75385 Small 4 sided Flange 36 5 8 W x 29 3 16 H 75388 Large 3 side...

Страница 18: ...in Picture C Turning the ball screw counter clockwise as you are look ing at it will give you less tension and turning the ball screw clockwise will give you more tension when opening and closing the...

Страница 19: ...ometer and check the pressure Again close the tap gently but securely after completing the check Check the taps for gas leaks with a gas leak test solution and retighten if necessary If the pressure i...

Страница 20: ...thermostat mural voir Figure B et le cas ch ant sur le bo tier delat l commande FigureC Pouracheverl instal lationcorrectedecefoyer proc dezcommesuitavec les tiquettesadh sivesenlangues trang resfourn...

Страница 21: ...d call your service technician or your gas sup plier 8 After pilot is lit turn gas control counterclockwise to ON Knob can only be turned ON if the knob has popped out 9 To turn burner on turn ON OFF...

Страница 22: ...To Turn Off Gas To Appliance above Gas Control Knob Pilot On Off Flame Height Control Knob Hi Lo Piezo Igniter WARNINGS Improper installation adjustment alteration service or maintenance can cause inj...

Страница 23: ...ry while adjusting flame appearance Theairshuttershouldneverbesetsoastomake the tips of the flames sooty or create sooting on the viewing glass logs or heat exchanger If sootbeginstoformafterburning t...

Страница 24: ...t is used Fire the fireplace insert four suc cessive times for ten minutes each time with a five minute cool down between each firing to cure the paint and burn off lubricants used in the manufacturin...

Страница 25: ...manufacturers instructions could result in a malfunction Pay special attention to the thermostat location require ments If the location requirements are not adhered to the appliance erratic operation...

Страница 26: ...roperly size the flames The flames should directly contact the thermopile and extend across the main burner ports Be careful not to back the screw out of its threads Replace the cover and check for ga...

Страница 27: ...the inside of the glass this condensation and fog will usually disappear in a few minutes This can cause lint dust and other airborne particles to cling to the glass surface Initialcuringofthehightemp...

Страница 28: ...chnician Perform the appropriate appliance checkout procedure detailed in this manual Replacing Rockwool Ember Materials Homeowner Qualified Service Technician Remove old ember materials and vacuum th...

Страница 29: ...efective igniter no spark at electrode Defective or misaligned electrode at pilot spark at electrode Check gas supply To purge hold in gas cock on valve for 1 2 minutes and try again Check for spark a...

Страница 30: ...ector 26 H5751 Blower Ducting 27 H5752 Wire Grommets 28 H5753 Burner Support 29 H5754 Front Leveling leg Assembly 30 H5755 Gasket kit 31 H5756 Surround Hinge 32 H5757 Ball Screw Assembly 33 H5758 Ball...

Страница 31: ...26 25 27 2 30 PART IDENTIFICATION Item Description 2 Air Intake Assembly 3 Blower Box Assembly 4 Flue Collar Assembly 5 Blower Snap Switch Assembly 23 Brick Panel Brackets 24 Surround Hanging Brackets...

Страница 32: ...LE Item Description 8 Burner Assembly 9 Pilot Assembly w Shield 10 Main Orifice 11 Bulkhead Assembly 12 Cassette Plate Assembly 13 Valve Assembly 14 Air Shutter Assembly 15 Cassette Assembly 30 Gasket...

Страница 33: ...T TO SCALE 8 PART IDENTIFICATION Item Description 2 Air Intake Assembly 3 Blower Box Assembly w Blower 6 Rear Leveling Leg Assembly 7 Outer Bottom Assembly 8 Burner Assembly 27 Wire Grommets 29 Front...

Страница 34: ...N 22 Ceramic Log Set Item Description 8 Burner Assembly 16 Louver Assembly 17 Blower Rheostat 18 Control Panel Valve Cover 19 On Off Switch Item Description 20 Igniter w nut 21 Door Assembly 22 Cerami...

Страница 35: ...e Surround Assembly Item Description 31 Surround Flange Hinge 32 Ball Screw Assembly 33 Ball Screw Catch Assembly 34 Surround Spacer Kit Small 35 Surround Spacer Kit Large 36 Extrusion Kit 3 Piece Sma...

Страница 36: ...ng the hand held remote control transmitter Screen Panel Kit This screen panel kit can be installed over the glass enclosure panel to help protect from making direct contact with the hot glass surface...

Страница 37: ...piece Small 75388 SHR SP 3P LG Surround Panel Kits 3 piece Large Width Height Cat No Model Description H7987 SHR BRK STD Brick Panel Set Tan H7988 SHR BRK RED Brick Panel Set Red H7989 SHR BRK ARCHSTO...

Страница 38: ...er Kit DVI 3 X 35 requires 2 one for exhaust and one for intake TKDVI TKDVI Termination Kit DVI termination cap and flashing DV3FK35 DV3FK35 Flex Liner and Termination Kit 3 X 35 includes 2 flex liner...

Страница 39: ...devant G le foyer H Distance verticale de la base de H l appareil aux combustibles Note Extension d tre fabriqu avec 1 minimum de mat riaux non combustible ou quivalent poss dant un facteur k de 0 84...

Страница 40: ...ion suppl mentaires contactez un installateur qualifi un agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d vacuation vous pourr...

Страница 41: ...41 NOTES...

Страница 42: ...anufacturer Normally all parts should be ordered through your Lennox distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the follow...

Отзывы: