background image

SPARE PARTS LIST

R

LENN  X

12

Size Used On :

Part Number

Description

150

190

260

330

440

E142

Air Vent (409992007)

X

X

X

X

X

Z303677

Cooling Coil 3 row  (Low Temp. 5 - 8 deg.C Flow)

X

Z303678

Cooling Coil 3 row  (Low Temp. 5 - 8 deg.C Flow)

X

Z303679

Cooling Coil 3 row  (Low Temp. 5 - 8 deg.C Flow)

X

Z303680

Cooling Coil 3 row  (Low Temp. 5 - 8 deg.C Flow)

X

Z303681

Cooling Coil 3 row  (Low Temp. 5 - 8 deg.C Flow)

X

Z303677

Cooling Coil 3 row (High Temp. 9 - 14 deg.C Flow)

X

Z303785

Cooling Coil 3 row (High Temp. 9 - 14 deg.C Flow)

X

Z303782

Cooling Coil 3 row (High Temp. 9 - 14 deg.C Flow)

X

Z303787

Cooling Coil 3 row (High Temp. 9 - 14 deg.C Flow)

X

Z303877

Cooling Coil 3 row (High Temp. 9 - 14 deg.C Flow)

X

Z303768

Cooling Coil 4 row  (Low Temp. 5 - 8 deg.C Flow)

X

Z303771

Cooling Coil 4 row  (Low Temp. 5 - 8 deg.C Flow)

X

Z303790

Cooling Coil 4 row  (Low Temp. 5 - 8 deg.C Flow)

X

Z303837

Cooling Coil 4 row  (Low Temp. 5 - 8 deg.C Flow)

X

Z303775

Cooling Coil 4 row  (Low Temp. 5 - 8 deg.C Flow)

X

Z303839

Cooling Coil 4 row (High Temp. 9 - 14 deg.C Flow)

X

Z303771

Cooling Coil 4 row (High Temp. 9 - 14 deg.C Flow)

X

Z303793

Cooling Coil 4 row (High Temp. 9 - 14 deg.C Flow)

X

Z303834

Cooling Coil 4 row (High Temp. 9 - 14 deg.C Flow)

X

Z303878

Cooling Coil 4 row (High Temp. 9 - 14 deg.C Flow)

X

Z301771

Fan Tray Assembly

X

Z301772

Fan Tray Assembly

X

Z301773

Fan Tray Assembly

X

SZ301774

Fan Tray Assembly

X

SZ302066

Fan Tray Assembly

X

SZ200669

Motor - Single Shaft (240v 50HZ)

X

X

SZ200668

Motor - Twin Shaft (240v 50HZ)

X

X

X

(x2)

SZ201112

Impeller - Aluminium.

X

(x2)

(x2)

(x3)

(x4)

ZZ-S211500030

Rocker Switch (On / Off)

X

X

X

X

X

ZZ-S211500031

Rocker Switch - 3 Position (Speed Change)

X

X

X

X

X

Z201657

Transformer (Auto 1.5amp.)

X

X

X

X

Z202103

Filter Assembly (EU2)

X

Z202104

Filter Assembly (EU2)

X

Z202105

Filter Assembly (EU2)

X

Z202106

Filter Assembly (EU2)

X

Z202107

Filter Assembly (EU2)

X

Z203290

Filter Assembly (EU3)

X

Z203291

Filter Assembly (EU3)

X

Z203292

Filter Assembly (EU3)

X

Z203293

Filter Assembly (EU3)

X

Z203294

Filter Assembly (EU3)

X

SZ303887

Drip Tray Assembly

X

SZ303888

Drip Tray Assembly

X

SZ303889

Drip Tray Assembly

X

SZ303890

Drip Tray Assembly

X

SZ303891

Drip Tray Assembly

X

Z301812

Plenum Dust / Spigot Caps (200 dia.)

X

X

X

X

X

Z304030

Plenum Dust / Spigot Caps (250 dia.)

X

X

X

X

X

Z291043

Condensate Pump Kit

X

X

X

X

X

Содержание Quantum Waterside LQWFC 150

Страница 1: ......

Страница 2: ...ns 4 Controls 4 Fan Speed Settings 5 Periodic Maintenance 6 Fancoil Maintenance 7 Coil Water Content 8 Weights 8 Minimum No Spigots 8 Coil Connections 8 Wiring Diagram 9 Fault Finding 10 Spares List 1...

Страница 3: ...s are to have maintenance free sealed for life bearings and built in thermal overload protec tion Insulation Dual function thermal and acoustic insulation shall be used and shall be to Class 0 specifi...

Страница 4: ...el PIPEWORK CONNECTIONS 1 Water flow and return connection Plain pipe connection tails are all to BS 2871 Part 1 1971 and are suitable for brazed or compression fittings Connection sizes are 15mm or 2...

Страница 5: ...acitor type and have a capacitor fixed to the outside of the motor All motors have thermal overload protection as standard Access to the fan tray is via removable panels on the bottom face of the unit...

Страница 6: ...ign speed EL 120 150 I 0 1 130 L 120 150 II 0 1 145 ML 135 165 II 0 1 160 M 150 180 II 0 1 175 H 165 195 III 0 0 195 Main tapping Fan speed switches Output Volts 150 W Y R 5 V 10 V design speed EL 120...

Страница 7: ...ace if necessary Ensureallelectricalconnectionsaresecure Check functions of controls according to operating procedures 6 Fan Motor and Fan A regular check on the fan motor assembly is advisable to asc...

Страница 8: ...ECK ACTUATOR EXAMINE VALVES ACTUATORS EXAMINE WATER FLOW TEMPERATURE CHECK CONTROLLER CHECK MOTOR CAPACITOR ADD LINK BETWEEN TERM 8 9 IF FCU WORKS CONTROL LER IS FAULTY CONTACT SPARES DEPT CONTACT SPA...

Страница 9: ...0 61 0 74 262 1 16 1 40 244 1 04 1 26 220 0 97 1 17 197 0 87 1 05 155 0 67 0 81 FAN MODEL SPEED Volts H 200 LQWFC M 170 150 ML 150 L 130 EL 120 H 170 LQWFC M 150 190 ML 140 L 130 EL 120 H 200 LQWFC M...

Страница 10: ...R LENN X 9 WIRING DIAGRAM...

Страница 11: ...R EMENT CALIBRATED CORRECTION FACTOR CHECK SOURCE OF CONTROLLER EXAMINE SWITCH WIRING CRIMP CONNECTIONS CONTINUITY TEST WIRES 24V AND MAINS OUTPUT OK BUT NEW FANCOIL FAULT FINDING CHECK QUANTITY LOCAT...

Страница 12: ...igh Temp 9 14 deg C Flow X Z303793 Cooling Coil 4 row High Temp 9 14 deg C Flow X Z303834 Cooling Coil 4 row High Temp 9 14 deg C Flow X Z303878 Cooling Coil 4 row High Temp 9 14 deg C Flow X Z301771...

Страница 13: ......

Отзывы: