background image

www.lennoxemea.com

PCUS Thermostat - User Manual - 0821EN

3

ATTENTION

  

ATTENTION:

 the equipment must be installed 

in accordance with the rules, make sure that the 
power supply is disconnected.

ATTENTION:

 the electrical connections, the 

installation of the heat recovery units and their 
accessories must be carried out only by persons 
in possession of the technical-professional 
requirements to qualify for the installation, 
transformation, expansion and maintenance of the 
systems and capable of to verify the same for the 
purposes of safety and functionality. In particular, 
for the electrical connections, the following checks 
are required:

•  The electrical connections to the control panels must be made by specialized personnel according to the diagrams 

provided.

•  Make sure that the voltage and frequency shown on the plate
•  correspond to those of the electrical connection line.
•  The use of adapters, multiple sockets and / or extensions is not allowed for the general power supply of the 

recuperator.

•  It is the installer’s duty to install the power supply disconnector as close as possible to the unit and what is 

necessary for the protection of the electrical parts.

•  Connect the unit to an effective earth socket, using the appropriate screw inserted in the unit itself.

1. COMPOSITION OF PCUS CONTROLLER

1.1 PCUS UNIT

The PCUS control system consists of two parts, an LCD display and setting and a control unit which contains the 
interface relays to be connected to the devices to be controlled, the connection inputs for the temperature probes.
The PCUSM system differs from the PCUS in the addition of a
Modbus RTU part.

2. PCUS REMOTE CONTROL INSTALLATION AND OPERATION

2.1 INSTALLATION OF PCUS REMOTE CONTROL

To secure the display to the electrical box:
•  release the front plate of the control, gently acting on the interlocking fasteners placed on the lower part
•  fix the base of the controller to the electrical box with two screws
•  reposition the front plate
The control unit is contained in the electrical box on the machine

Make the connection with cables with a section suitable for the power used and in compliance with local 
regulations. Their size must in any case be such as to achieve a voltage drop in the starting phase of less 
than 3% of the nominal one

• 

Measurement of the insulation resistance of 
the electrical system  

• 

Continuity test of the protective conductors.

ATTENTION:

 before carrying out any intervention,  

equip yourself with suitable personal protective 
equipment.

ATTENTION:

 Touching live components can cause   

a dangerous electric shock.

ATTENTION: also consult the installation 
manual supplied with the unit.

Before starting any operation, make sure that the general 
power supply line is disconnected.

Содержание PCUS

Страница 1: ...CUS Thermostat User Manual Before starting to work with the machine operation read the installation use and maintenance manual PCUS PCUSM Thermostat User manual Installation use and maintenance manual...

Страница 2: ...ATURE REGULATION 3 3 OPERATION OF HEAT RECOVERY DEFROST 3 5 AIR INLET OUTLET DAMPER OPERATION 3 6 FREE HEATING COOLING LOGIC OPERATION 3 7 DIRTY FILTER INLET SIGNAL 3 8 REMOTE ON OFF SIGNAL 3 9 EXTERN...

Страница 3: ...self 1 COMPOSITION OF PCUS CONTROLLER 1 1 PCUS UNIT The PCUS control system consists of two parts an LCD display and setting and a control unit which contains the interface relays to be connected to t...

Страница 4: ...Button 2 Mode Button 3 Ventilation Button 4 Button 5 Button 6 Ventilation Symbol Area Graphical Area 1 Probe indicator displayed on line 2 2 Room temperature and fan icons display 3 Visualization of r...

Страница 5: ...and the key 5 allow you to modify the temperature set point 2 6 ELECTRICAL CONNECTION Refer to the attached connection diagram 2 7 PCUS DESCRIPTION The PCUS control system is a thermostat capable of c...

Страница 6: ...mode adjustment is envisaged this mode will be fixed with the 10C icon always active and pressing the Mode key will have no effect Similarly if at the manufacturer level only adjustment in cold mode i...

Страница 7: ...set for week 1 which identifies the days from Monday to Friday week 6 which identifies Saturday and week 7 which identifies Sunday The following can be selected ventilation speed temperature set poin...

Страница 8: ...values and temperature The photo below shows what is indicated in this point 12 Press the Mode key to switch to the setting of band 1 on Saturday identified by the wording Week 6 and set the desired...

Страница 9: ...firming all the previously set values by pressing the Mode button several times 22 Change the setting of the desired action from ON to OFF with the or keys The photo below shows what is indicated in t...

Страница 10: ...the and keys and then press M to confirm the values The user parameters table is shown below Meaning U0 0 Temperature set point C min 15 max 35 U0 1 Temperature differential C min 0 max 5 U0 2 Antifre...

Страница 11: ...0 6 from 0 to 1 The adjustment can be only hot only cold hot and cold In the case of heating only adjustment the 10C icon will be lit and the actual activation of the water valve or the electric heati...

Страница 12: ...be activated when the contact is opened The activation of the dirty filters function activates the signal given by the 4th icon however by default it does not perform any action allowing normal operat...

Страница 13: ...return air fan speed 1 9 V 40004 R W L0 c Maximum return air fan speed da L0 9 10 V 40016 R W U0 0 Set temperature 15 0 35 0 C 40017 R W U0 1 Temperature differential 0 0 5 0 C 40018 R W U0 2 Antifree...

Страница 14: ...to the electronic board before proceeding with the modification The following table shows the meaning of the DIP switches NUMBER MEANING VALUE 1 Unit with three speed fans 0 NO 1 YES 2 Unit with EC fa...

Страница 15: ...mmitment to quality the specifications ratings and dimensions are subject to change without notice and without incurring liability Improper installation adjustment alteration service or maintenance ca...

Отзывы: