Page 2
OF23 Unit Dimensions − Inches (mm)
FLUE CONNECTION
OF23Q3/4-105/120R,
OF23Q5-140/154R
OF23Q5−175/210R
1
(25)
1 (25)
RETURN
AIR
OPENING
SUPPLY
AIR
OPENING
OIL PIPING INLET
(Both Sides)
ELECTRICAL INLETS
(Right Side Only)
TOP VIEW
SIDE VIEW
FRONT VIEW
A
E
C
E
3/4
(19)
FLUE CONNECTION
OF23Q3/4-105/140 &
OF23Q5-140/154
(On Heat Exchanger)
AIR
FLOW
AIR
FLOW
3/4
(19)
3/4
(19)
3/4
(19)
1-1/2
(38)
3-1/4
(83)
6-1/2
(165)
B
C
F
G
SIDE
FLUE OUTLET
CENTERING HOLE
(Field Fabricate
Either Side)
OPT. OUTDOOR
COMBUSTION
AIR INLET
CENTERING HOLE
(Field Fabricate
Right Side only)
TOP FLUE
OUTLET
Model No
A
B
C
D
E x F (Supply)
E x G (Return)
Model No.
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
in.
mm
OF23Q3/4-105/120
19-1/2
4959
37
940
52−1/2
1334
27
686
18 x 21
457 x 533
18 x 16
457 x 406
OF23Q3/4-105/120R
19-1/2
495
37
940
52−1/2
1334
27
686
18 x 21
457 x 533
18 x 16
457 x 406
OF23Q5-140/154
22-1/2
572
37
940
52−1/2
1334
27
686
21 x 21
533 x 533
21 x 16
533 x 406
OF23Q5-140/154R
22-1/2
572
37
940
52−1/2
1334
27
686
21 x 21
533 x 533
21 x 16
533 x 406
OF23Q5-175/210R
24
610
39−1/4
997
55
1397
29
737
22−1/2 x 23−1/8
572 x 587
22−1/2 x 16−1/2
572 x 419
OF23 Start−Up & Performance Check List
Filter Clean & Secure?
Supply Voltage
Electrical Connections Tight?
Job Name
Job Location
Installer
Unit Model No.
Oil Pump Pressure [recommended minimum 140 psi]
Job No.
City
City
Serial No.
Date
State
Serviceman
Draft Reading (recommended .03−.04 inches w.c.)
Flue Connections Tight?
HEATING SECTION
THERMOSTAT
Calibrated?
Heat Anticipator Properly Set?
Level?
Blower Motor Amps
Blower Motor H.P.
Blower Motor Lubrication O.K.?
Piping Connections Tight?
Vent Clear?
State
Temperature Rise
Fan Control Cutout
Fan Control Setting (maximum 130
_
F)
Burner Model No.
Serial Number
All Valves Open?
PROPER DRAFT
% CO
2
(recommended 12%)
(55
_
C)