• 15 •
NAH
NEOSYS
NAH
340
380
420
480
kW
324
361
397
454
128,4
133,1
155,1
179,4
A
223,3
231,4
269,7
311,9
EER
(1)
2,52
2,71
2,56
2,53
ESEER
(2)
4,01
4,08
3,86
4,14
4,23
4,20
4,12
4,16
%
166
165
162
163
5,21
5,25
5,11
5,12
3,23
3,09
3,11
3,19
kW
363
404
452
499
121,3
132,9
151,7
169,5
A
125,9
145,3
172,8
192,5
COP
(3)
3,00
3,04
2,98
2,95
3,47
3,39
3,33
3.35
%
136
132
130
131
A+
5
6
6
6
%
18 - 41 - 59 -
82 - 100
17 - 33 - 50 - 67
- 83 - 100
14 - 33 - 48 - 67
- 81 - 100
17 - 33 - 50 - 67
- 83 - 100
(6,8 x 3)
+ (6,3 x 2)
(6,8 x 3)
+ (6,8 x 3)
(6,3 x 3)
+ (6,8 x 3)
(6,3 x 3)
+ (6,3 x 3)
2
kg
42
50
52
52
6
8
8
8
6
8
8
8
mm
800
m
3
/h
114 000
152 000
152 000
152 000
kW
9,6
12,8
12,8
12,8
m
3
/h
55,7
62,1
68,4
78,1
34,6
34,6
34,6
42,7
kPa
29,8
36,5
43,6
42,3
600
5"
400V / III / 50 Hz
A
527,9
579,6
594,8
638,9
277,2
328,9
344,1
388,2
410A
R
Application Guide /NEOSYS-AGU-1801-E
HEAT PUMP
Cooling mode
Cooling capacity
(1)
Total absorbed power
(1)
Full load amps
(1)
Seasonal Energy Ef
fi
ciency Ratio
(4)
SEER
Seasonal energy ef
fi
ciency
(3)
ɳ
s,h
Seasonal Energy Performance Ratio
(5)
SEPR
- High temperature (7°C)
Seasonal Energy Performance Ratio
(6)
SEPR
- Medium temperature (-8°C)
Heating mode
Heating capacity
(1)
Power input
(1)
Full load amps
(1)
Seasonal energy ef
fi
ciency
(8)
SCOP
Seasonal energy ef
fi
ciency
(7)
ɳ
s,h
Seasonal energy ef
fi
ciency class
(9)
Compressors
Scroll - Hermetic
Number of compressors
Capacity steps
Oil type
MOBIL EAL Arctic 22CC or ICI EMKARATE RL32CF
Oil load per compressor
l
Refrigeration circuit
Number of circuit
Refrigerant load per circuit (R410A)
Type of expansion valve
Thermostatic expansion valve
Condenser
Copper tube - Aluminium
fi
n - Air-cooled
Number of condenser
Fan & Motor
Variable speed fans
Number of fans
Diameter
Maximum speed
Variable speed - 900 rpm maximum
Nominal air
fl
ow (100%)
Total motor power input
Evaporator
AISI 304 stainless steel plate brazed with copper heat exchanger
Water
fl
ow
(1)
Water volume
l
Pressure drop
(1)
Water operating pressure
Hydraulic connections
Victaulic
Water inlet/outlet
Inches
Electrical data
Starting current
Maximum current
GENERAL DATA
(1) EUROVENT certi
fi
ed data, in accordance with
standard EN14511 :
Water inlet / outlet temperature = 12 °C / 7 °C
Outdoor air temperature = 35 °C.
(2) ESEER following Eurovent calculation method,
in accordance with standard EN14511
(3)
Following ecodesign regulation nr
EU 2016/2281
on space cooling, normalized
leaving water temperature at 7 °C, in
accordance with standard EN14825.
(4)
SEER in accordance with standard
EN14825.
(5)
Following ecodesign regulation nr
EU 2016/2281
on process cooling units,
normalized leaving water temperature at 7°C,
in accordance with standard EN14825.
(6)
Following ecodesign regulation nr
EU 2015/1095
on process cooling chillers,
normalized leaving water temperature at
-8°C, in accordance with standard EN14825
(7)
SCOP in accordance with standard
EN14825. Heating mode performance is
de
fi
ned for average climate.
(8)
Following ecodesign regulation nr
EU 813/2013
on space heaters, normalized
leaving water temperature at 7°C, in
accordance with standard EN14825, average
climate.
(9)
Following energy labelling regulation nr
EU 811/2013
on space heaters.
Comfort
applica-
tions
Comfort
applications
Process
applica-
tions