10
6. Wireless Remote
IMPORTANT!
Frequent changes to operating mode may cause system
malfunction. Allow at least one minute between mode
changes for the system to stabilize.
6.1. Requirements
Using the remote controller
•
Point the remote controller directly at the indoor unit.
•
Stand within 26 feet (8 meters) of the indoor unit.
•
Do not block the signal between the remote controller
and indoor unit.
NOTE:
The remote controller will not function without a
clear line of sight to the indoor unit.
•
Do not submerge the remote controller in liquid.
•
Do not expose to direct sunlight.
•
Do not drop or step on remote controller.
•
Remote control holder
Use field-provided fasteners to attach the remote controller
holder to any suitable vertical surface such as a wall.
6.2.
Remote Control Specifications
Table 2.
Specifications
Function
Specifications
Rated voltage
3.0 VDC (2 AAA batteries)
Min voltage for sending signal to
CPU
2.4 VDC
Effective transmitting distance
26 feet (8 meters)
Operation conditions
23°F to 140°F (-5 to 60°C)
FP
(Button Disabled)
ON/OFF
Turns the system on or off
MODE
Scrolls through operation
modes as follows:
FAN
Selects fan speeds in the
following order:
SLEEP
Saves energy during
sleeping hours
NOTE - Hold button for
2 seconds to activate
Silence function.
TURBO
Enables unit to reach
preset temperature in
shortest possible time
.
TIMER ON
Sets timer to turn unit on
SWING/DIRECT
SWING
Used to start or stop horizontal louver auto-swing feature.
Louver will swing up and down automatically when activated.
DIRECT
Used to change the louver movement and set the desired
up/down air flow direction. The louver angle changes 6° for
each press of the button.
LED
Turns indoor unit’s LED display on and off.
If you are sensitive to light when you go to
sleep, you can press the LED button to turn
off the LED display on the indoor unit. Press
the button again to turn it back on.
FOLLOW (ME)
Temperature sensing at the remote controller location
CLEAN
Starts and stops
self clean feature
ON/OFF
TEMP
FP
TIMER
ON
TIMER
OFF
MODE
FAN
SLEEP
TURBO
SWING
DIRECT
CLEAN
LED
FOLLOW
NOTE - Heat mode is not
available on
air conditioner models.
COOL → DRY →
→ FAN
AUTO → LOW → MED →
HIGH
TEMP ▲
Increases temperature in
1°F increments
(Max. Temperature is 86°F)
TEMP ▼
Decreases temperature in
1°F increments
(Min. Temperature is 62°F)
NOTE - Press and hold ▲and ▼
buttons simultaneously for 3 seconds
to switch from °F to °C.
TIMER OFF
Sets timer to turn unit off
Figure 10. Remote Controller Function Buttons