WIRING DIAGRAMS

Wiring diagrams are provided here for reference purposes only.  This information is also provided on schematics attached directly to the appliance
on a pullout panel located within the control compartment.

CAUTION:  LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS.  WIRING ERRORS CAN CAUSE IMPROPER
AND DANGEROUS APPLIANCE OPERATION.

WARRANTY

Your gas appliance is covered by a limited
twenty year warranty. You will find a copy of
the warranty accompanying this manual.
Please read the warranty to be familiar with
its coverage.

Retain this manual. File it with your other docu-
ments for future reference.

REPLACEMENT PARTS

A complete parts list is found at the end of this
manual. Use only parts supplied from the
manufacturer.

Normally, all parts should be ordered through
your Lennox distributor or dealer. Parts will be
shipped at prevailing prices at time of order.

When ordering repair parts, always give the
following information:

PRODUCT REFERENCE INFORMATION

We recommend that you record the following important information about your fireplace.  Please
contact your Lennox dealer for any questions or concerns.  For the number of your nearest Lennox
dealer, please call 1-800-9-LENNOX

Your Fireplace's Model Number _______________________________________

Your Fireplace's Serial Number ________________________________________

The Date On Which Your Fireplace Was Installed __________________________

The Type of Gas Your Fireplace Uses ___________________________________

Your Dealer's Name _________________________________________________

If you encounter any problems or have any
questions concerning the installation or appli-
cation of this system, please contact your dis-
tributor, or Lennox directly:

LENNOX HEARTH PRODUCTS

1110 West Taft Avenue
Orange, CA  92865

1.

 The model number of the appliance.

2.

 The serial number of the appliance.

3.

 The part number.

4.

 The description of the part.

5.

 The quantity required.

6.

 The installation date of the appliance.

SIT And Honeywell Millivolt Wiring Diagram

If any of the original wire as supplied must be replaced,
it must be replaced with

 

Type AWM105

°

C – 18 GA. wire.

Thermopile

TH

TP

TH

TP

*TWIST WIRES “A” AND “B” TOGETHER TO OPERATE UNIT

SOLELY BY MANIPULATING THE GAS VALVE CONTROL KNOB;

OR CONNECT WIRES TO  OPTIONAL ON/OFF SWITCH OR WALL

SWITCH OR THERMOSTAT TO OPERATE UNIT.

*OPTIONAL

 ON/OFF SWITCH,

 WALL SWITCH, THERMOSTAT

OR REMOTE CONTROL RECEIVER

A

B

1. If any of the original wire as supplied must be replaced,

1.  

it must be replaced with

 

Type AWM 105

°

C – 18 GA. wire.

2. 120V, 60Hz – Less than 3 amps.

BK

Transf.

120 V.

24 V

Factory Wired

Field Wired

BL

Electronic Wiring Diagram (Honeywell)

Showing the Blower Wiring for the Optional

FBK-100 and FBK-200 Kits

R

W

BL

W

Gas Valve

B

R

IGNITER

BK

*Blower speed control switch is provided in FBK200 blower kit.

Schematic Representation Only

**ON/OFF Switch (Integral

with Gas Valve)

**Leave the ON/OFF switch, which is integral

with the gas valve, in the ON position.

OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH

 OR OPTIONAL WALL SWITCH

OR OPTIONAL THERMOSTAT

OR OPTIONAL REMOTE RECEIVER

G

OPT

BLOWER

PILOT

ASSEMBLY

Junction Box

White

Green

Red

Black

Neutral
Side of
Receptacle

Tab Intact

Green
Ground
Screw

Hot
Side of
Receptacle

Tab
Broken

120 VAC - Black

n

e

e

r

G

-

d

n

u

o

r

G

Optional

Accessory

Switch

e

t

i

h

W

-

l

a

r

t

u

e

N

1. If any of the original wire as supplied must be replaced,

1.  

it must be replaced with

 

Type AWM 105

°

C – 18 GA. wire.

2. 120V, 60Hz – Less than 3 amps.

BK

Transf.

120 V.

24 V

Factory Wired

Field Wired

BL

Electronic Wiring Diagram (Honeywell)

Showing the Blower Wiring for the Optional

FBK-250 Kits

R

WH

BL

W

Gas Valve

B

R

IGNITER

BK

Schematic Representation Only

*ON/OFF Switch (Integral

with Gas Valve)

Optional
FBK-250

Module

*Leave the ON/OFF switch, which is integral

with the gas valve, in the ON position.

G

OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH

 OR OPTIONAL WALL SWITCH OR OPTIONAL THERMOSTAT

OR OPTIONAL REMOTE RECEIVER

PILOT

ASSEMBLY

OPT

BLOWER

Junction Box

White

Green

Red

Black

Neutral
Side of
Receptacle

Tab Intact

Green
Ground
Screw

Hot
Side of
Receptacle

Tab
Broken

Optional

Accessory

Switch

120 VAC - Black

n

e

e

r

G

-

d

n

u

o

r

G

e

t

i

h

W

-

l

a

r

t

u

e

N

Содержание MPD-33 Series

Страница 1: ...t treex cut parunqualifi installeur agence de service ou le fournisseur de gaz DIRECT VENT MPD 33 35 40 45 SERIES MODELS OTL Report No 116 F 13 4 s l e d o M t l o v i l l i M s l e d o M c i n o r t...

Страница 2: ...ired to operate these units These appliances comply with National Safety Standards and are tested and listed by Omni Test Laboratories Report No 116 F 13 4 to ANSI Z21 88 2000 in Canada CSA 2 33 2000...

Страница 3: ...7 2 o t 0 0 5 1 2 0 4 5 4 D P M 0 0 0 9 2 o t 0 0 5 2 2 e v l a V s a G e t a R d e x i F h t i w s l e d o M c i n o r t c e l E s a G e n a p o r P d n a l a r u t a N s e i r e S l e d o M H U T B...

Страница 4: ...FF P I L OT L O H I Manifold Pressure Port Inlet Pressure Port Optional ON OFF Rocker Switch Location One of Two Places Piezo Ignitor Optional Burner ON OFF Rocker Switch Location SIT Millivolt Gas Va...

Страница 5: ...page 7 and verify the flame pattern and height displayed by the appliance conforms to the picture Flames must not impinge on the logs Refer to Figure 10 SIT Millivolt Figure 11 Honeywell Millivolt or...

Страница 6: ...TEMPT TO TOUCH THE FRONT ENCLOSURE GLASS WITH YOUR HANDS WHILE THE FIREPLACE IS IN USE Note Clean glass after first two weeks of operation Glass Cleaning It will be necessary to clean the glass period...

Страница 7: ...ith traces of orange at the outer edge The top 10 mm at the pilot generator thermopile and the top min tip of the quick drop out thermocouple should be en gulfed in the pilot flame The flame should pr...

Страница 8: ...c fiber logs and twigs over the burner as shown in Figures 7 MPD 3328 8 MPD 3530 or 9 MPD 4035 MPD 4540 For more detailed placement instructions refer to the LOG PLACEMENT GUIDE accompanying this docu...

Страница 9: ...e of the appliance SIT And Honeywell Millivolt Wiring Diagram If any of the original wire as supplied must be replaced it must be replaced with Type AWM105 C 18 GA wire Thermopile TH TP TH TP TWIST WI...

Страница 10: ...10 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES...

Страница 11: ...ttery power level in dicator timer mode of operation thermostatic display including room temperature in either metric of English units flame indicator and clock Fully programmable the Model RCL T allo...

Страница 12: ...L 1 8 B P C 5 4 K D A d e h s u r B s s e l n i a t S h s i n i F 2 6 L 8 9 S B C 3 3 K D A 4 4 M 6 2 S B M C 5 3 K D A 9 6 L 8 9 S B C 0 4 K D A 0 7 L 8 9 S B C 5 4 K D A s t i K l e n a P n e e r c...

Страница 13: ...are designed to replace the standard radiant panels that are provided with the fireplace or they may be used to replace the charcoal colored louvers also available with this fireplace They include a t...

Страница 14: ...5 H0935 APD40TI 40 Arch Pane Doors Textured Iron H0936 APD40SP 40 Arch Pane Doors Satin Pewter H0937 APD40AB 40 Arch Pane Doors Antique Brass H0938 APD45C 45 Arch Pane Doors Charcoal MPD4540 H0939 APD...

Страница 15: ...3571 35 Sunrise Lower Grille Kit Satin Pewter SLGK35SP H3573 SUGK40C 40 Sunrise Upper Grille Kit Charcoal H3575 40 Sunrise Upper Grille Kit Satin Pewter SUGK40SP H3577 SLGK40C 40 Sunrise Lower Grille...

Страница 16: ...triggering the spark ignitor pushing the button until pilot lights Continue to hold the control knob in for about 1 minutes after the pilot is lit Release knob and it will pop back up Pilot should rem...

Страница 17: ...z le service des incendies C N utilisez que votre main pour manipuler le bouton de r glage du gaz N utilisez jamais d outils Si le bouton refuse de tourner ou de bouger n essayez pas de le r parer Com...

Страница 18: ...part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS ELECTRONIC 1 For complete shut down turn remote wall switch to OFF 2 Open lower control compartment doo...

Страница 19: ...sition d arr t OFF 3 Ouvrez la porte du compartiment de contr le du bas 4 Assurez vousquelasoupaped arr tdelacanalisationprincipale est ouverte 5 Tournezlamanetteder glagedugaz lapositiond arr t OFF 6...

Страница 20: ...t pilot flame for maximum flame im pingement on thermocouple Figure 10 page 8 SIT and Figure 11 page 8 Honeywell Check burner orifice for stoppage and remove Checkthermopilewithmillivoltmeter Takeread...

Страница 21: ...NO Plug Control Harness Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burner Cable Connected Measure Voltage At Valve HSI Element Output 24V Nominal See Insert...

Страница 22: ...5 2 M 4 2 1 5 2 M 4 2 1 9 y l b m e s s A r e n r u B 8 5 M 4 2 1 8 5 M 4 2 1 9 5 M 4 2 1 9 5 M 4 2 1 0 1 y l b m e s s A e t a r G 3 8 5 4 H 1 3 8 5 4 H 1 3 8 5 4 H 1 3 8 5 4 H 1 1 1 r e n r u B n i...

Страница 23: ...TE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS 4 7 1 11 5 40 13 12 6 42 3 8 9 30 31 32 33 34 35 40 45 40 45 14 36 37 15 9 33 35 33 35 8 20 21 10 40 45 33 35 10 23 22 24 26 25 27 41 43 44 2 R...

Страница 24: ...5 014M REV K 03 2007 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products C...

Отзывы: