background image

2

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

These appliances are designed to operate on
natural or propane gas only.

Input of millivolt models is variable. These
rates are shown in the following tables:

CONGRATULATIONS!

In selecting this LENNOX Direct-Vent Gas Appliance you have chosen the finest and most
dependable fireplace to be found anywhere.  A beautiful, prestigious, alternative to a
wood burning fireplace.  Welcome to a Family of tens of thousands of satisfied LENNOX
Fireplace Owners.

Please read and carefully follow all of the instructions found in this manual.  Please pay
special attention to the safety instructions provided in this manual.  The Homeowner's
Care and Operation Instructions included here will assure that you have many years of
dependable and enjoyable service from your LENNOX product.

INTRODUCTION

The Fireplace models covered in this manual
are Direct-Vent sealed combustion vented gas
fireplace heaters designed for residential ap-
plication.  Direct-Vent appliances operate with
the combustion chamber completely isolated
from the inside atmosphere.  All air for com-
bustion is brought in from the outside and
exhaust gases are vented through the same
direct vent, vent system.

GENERAL INFORMATION

Note: 

Installation and repair should be per-

formed by a qualified service person. The appli-
ance should be inspected annually by a quali-
fied professional service technician. More fre-
quent inspections and cleanings may be re-
quired due to excessive lint from carpeting,
bedding material, etc. It is imperative that the
control compartment, burners and circulating
air passage ways of the appliance be kept clean.

S'assurer que le brùleur et le compartiment
des commandes sont propres.  Voir les in-
structions d'installation et d'utilisation qui
accompagnent l'appareil.

Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.

Due to high temperatures the appliance should
be located out of traffic and away from furni-
ture and draperies.  Locate furniture and win-
dow coverings accordingly.

The millivolt appliances are designed to oper-
ate on either natural or propane gas. A millivolt
gas control valve with piezo ignition system
provides safe, efficient operation.  External
electrical power is required to operate the
optional electrically powered components if
installed.  Electrical power must be wired
during appliance installation.

The electronic appliances are designed to op-
erate on either natural or propane gas. An
electronic intermittent pilot system provides
safe, efficient operation. External electrical
power is required to operate these units.

These appliances comply with National Safety
Standards and are tested and listed by Omni-
Test Laboratories (Report No. 116-F-13-4) to
ANSI Z21.88-2000 (in Canada, CSA-2.33-
2000), and CAN/CGA-2.17-M91 in both USA
and Canada, as vented gas fireplace heaters.

Installation must conform to local codes. In
the absence of local codes, installation must
comply with the current National Fuel Gas
Code, ANSI Z223.1 (NFPA 54). (In Canada, the
current CAN/CGA B149 installation code.)  Elec-
trical wiring must  comply with local codes.  In
the absence of local codes, installation must
be in accordance with the National Electrical
Code, NFPA 70 - (latest edition). (In Canada,
the current CSA C22.1 Canadian Electric Code.)

DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR ITS
COMPONENTS. ANY MODIFICATION OR ALTER-
ATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.

TABLE OF CONTENTS

Introduction ..................................... page

2

General Information ......................... page

2

Operation/Care of Your Appliance .... page

3

Gas Controls/Compartment Access . page

3

Variable Flame Adjustment .............. page

4

Maintenance Schedule ..................... page

5

Maintenance .................................... page

6

Glass Cleaning ................................. page

6

Front Glass Enclosure Panel,

  Removal and Installation ............... page

6

Burner Adjustments ......................... page

6

Flame Appearance and Sooting ....... page

6

Adjustment ...................................... page

7

Log Placement ................................. page

7

Rockwool Placement ....................... page

7

Vermiculite Placement ..................... page

7

Volcanic Stone Placement ............... page

7

Millivolt Appliance Checkout ............ page

7

Electronic Appliance Checkout ......... page

8

Wiring Diagrams .............................. page

9

Warranty .......................................... page

9

Replacement Parts .......................... page

9

Product Reference Information ....... page

9

Accessory Components ................... page 11

Lighting Instructions – Millivolt ....... page 16

Lighting Instructions – Electronic .... page 18

Troubleshooting Guide – Millivolt ..... page 20

Troubleshooting Guide – Electronic .. page 21

Replacement Parts List ..................... page 22

h

t

i

w

s

l

e

d

o

M

t

l

o

v

i

l

l

i

M

e

v

l

a

V

s

a

G

d

e

t

a

l

u

d

o

M

-

y

l

l

a

u

n

a

M

s

a

G

l

a

r

u

t

a

N

s

e

i

r

e

S

l

e

d

o

M

)

H

/

U

T

B

(

e

t

a

r

t

u

p

n

I

8

2

3

3

-

T

D

P

M

8

2

3

3

-

R

D

P

M

0

0

5

,

7

1

o

t

0

0

7

,

1

1

0

3

5

3

-

D

P

M

0

0

0

,

0

2

o

t

0

0

8

,

2

1

5

3

0

4

-

D

P

M

0

0

0

,

7

2

o

t

0

0

5

,

8

1

0

4

5

4

-

D

P

M

0

0

0

,

9

2

o

t

0

0

5

,

0

2

WARNING:  THESE FIREPLACES ARE
VENTED HEATERS.  DO NOT BURN
WOOD OR OTHER MATERIAL IN THESE
APPLIANCES.

WARNING:  IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE.  REFER TO
THIS MANUAL.  FOR ASSISTANCE OR
ADDITIONAL INFORMATION CONSULT
A QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.

WARNING: ELECTRONIC MODELS OF
THESE APPLIANCES ARE EQUIPPED
WITH A THREE-PRONG (GROUNDING)
PLUG UTILIZED IN CONNECTING THE
ELECTRONIC COMPONENTS TO THE
JUNCTION BOX IN THE LOWER COM-
PARTMENT.  THIS GROUNDING PLUG
PROVIDES PROTECTION AGAINST
SHOCK HAZARD AND SHOULD BE
PLUGGED DIRECTLY INTO THE PROP-
ERLY GROUNDED THREE-PRONG RE-
CEPTACLE.  DO NOT CUT OR REMOVE
THE GROUNDING PRONG FROM THE
PLUG.

Содержание MPD-33 Series

Страница 1: ...t treex cut parunqualifi installeur agence de service ou le fournisseur de gaz DIRECT VENT MPD 33 35 40 45 SERIES MODELS OTL Report No 116 F 13 4 s l e d o M t l o v i l l i M s l e d o M c i n o r t...

Страница 2: ...ired to operate these units These appliances comply with National Safety Standards and are tested and listed by Omni Test Laboratories Report No 116 F 13 4 to ANSI Z21 88 2000 in Canada CSA 2 33 2000...

Страница 3: ...7 2 o t 0 0 5 1 2 0 4 5 4 D P M 0 0 0 9 2 o t 0 0 5 2 2 e v l a V s a G e t a R d e x i F h t i w s l e d o M c i n o r t c e l E s a G e n a p o r P d n a l a r u t a N s e i r e S l e d o M H U T B...

Страница 4: ...FF P I L OT L O H I Manifold Pressure Port Inlet Pressure Port Optional ON OFF Rocker Switch Location One of Two Places Piezo Ignitor Optional Burner ON OFF Rocker Switch Location SIT Millivolt Gas Va...

Страница 5: ...page 7 and verify the flame pattern and height displayed by the appliance conforms to the picture Flames must not impinge on the logs Refer to Figure 10 SIT Millivolt Figure 11 Honeywell Millivolt or...

Страница 6: ...TEMPT TO TOUCH THE FRONT ENCLOSURE GLASS WITH YOUR HANDS WHILE THE FIREPLACE IS IN USE Note Clean glass after first two weeks of operation Glass Cleaning It will be necessary to clean the glass period...

Страница 7: ...ith traces of orange at the outer edge The top 10 mm at the pilot generator thermopile and the top min tip of the quick drop out thermocouple should be en gulfed in the pilot flame The flame should pr...

Страница 8: ...c fiber logs and twigs over the burner as shown in Figures 7 MPD 3328 8 MPD 3530 or 9 MPD 4035 MPD 4540 For more detailed placement instructions refer to the LOG PLACEMENT GUIDE accompanying this docu...

Страница 9: ...e of the appliance SIT And Honeywell Millivolt Wiring Diagram If any of the original wire as supplied must be replaced it must be replaced with Type AWM105 C 18 GA wire Thermopile TH TP TH TP TWIST WI...

Страница 10: ...10 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES...

Страница 11: ...ttery power level in dicator timer mode of operation thermostatic display including room temperature in either metric of English units flame indicator and clock Fully programmable the Model RCL T allo...

Страница 12: ...L 1 8 B P C 5 4 K D A d e h s u r B s s e l n i a t S h s i n i F 2 6 L 8 9 S B C 3 3 K D A 4 4 M 6 2 S B M C 5 3 K D A 9 6 L 8 9 S B C 0 4 K D A 0 7 L 8 9 S B C 5 4 K D A s t i K l e n a P n e e r c...

Страница 13: ...are designed to replace the standard radiant panels that are provided with the fireplace or they may be used to replace the charcoal colored louvers also available with this fireplace They include a t...

Страница 14: ...5 H0935 APD40TI 40 Arch Pane Doors Textured Iron H0936 APD40SP 40 Arch Pane Doors Satin Pewter H0937 APD40AB 40 Arch Pane Doors Antique Brass H0938 APD45C 45 Arch Pane Doors Charcoal MPD4540 H0939 APD...

Страница 15: ...3571 35 Sunrise Lower Grille Kit Satin Pewter SLGK35SP H3573 SUGK40C 40 Sunrise Upper Grille Kit Charcoal H3575 40 Sunrise Upper Grille Kit Satin Pewter SUGK40SP H3577 SLGK40C 40 Sunrise Lower Grille...

Страница 16: ...triggering the spark ignitor pushing the button until pilot lights Continue to hold the control knob in for about 1 minutes after the pilot is lit Release knob and it will pop back up Pilot should rem...

Страница 17: ...z le service des incendies C N utilisez que votre main pour manipuler le bouton de r glage du gaz N utilisez jamais d outils Si le bouton refuse de tourner ou de bouger n essayez pas de le r parer Com...

Страница 18: ...part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS ELECTRONIC 1 For complete shut down turn remote wall switch to OFF 2 Open lower control compartment doo...

Страница 19: ...sition d arr t OFF 3 Ouvrez la porte du compartiment de contr le du bas 4 Assurez vousquelasoupaped arr tdelacanalisationprincipale est ouverte 5 Tournezlamanetteder glagedugaz lapositiond arr t OFF 6...

Страница 20: ...t pilot flame for maximum flame im pingement on thermocouple Figure 10 page 8 SIT and Figure 11 page 8 Honeywell Check burner orifice for stoppage and remove Checkthermopilewithmillivoltmeter Takeread...

Страница 21: ...NO Plug Control Harness Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burner Cable Connected Measure Voltage At Valve HSI Element Output 24V Nominal See Insert...

Страница 22: ...5 2 M 4 2 1 5 2 M 4 2 1 9 y l b m e s s A r e n r u B 8 5 M 4 2 1 8 5 M 4 2 1 9 5 M 4 2 1 9 5 M 4 2 1 0 1 y l b m e s s A e t a r G 3 8 5 4 H 1 3 8 5 4 H 1 3 8 5 4 H 1 3 8 5 4 H 1 1 1 r e n r u B n i...

Страница 23: ...TE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS 4 7 1 11 5 40 13 12 6 42 3 8 9 30 31 32 33 34 35 40 45 40 45 14 36 37 15 9 33 35 33 35 8 20 21 10 40 45 33 35 10 23 22 24 26 25 27 41 43 44 2 R...

Страница 24: ...5 014M REV K 03 2007 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products C...

Отзывы: