       WARNING 

Do not install or operate this fire-

place through a switch wired in the 

120 VAC or  240 VAC circuits.  The 

only approved wiring for a switch 

is through the low voltage circuit  

(24 VAC) as shown on 

Page 14

.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

3

CONGRATULATIONS!

In selecting this LENNOX Merit Plus electric fireplace, you have chosen the finest and 

most dependable fireplace found anywhere.  A beautiful and prestigious addition to 

the finest homes.  Welcome to a Family of hundreds of thousands of satisfied LENNOX 

Fireplace Owners.

Please read and carefully follow all of the instructions found in this manual.  Please 

pay special attention to the safety instructions provided in this manual.  The instruc-

tions included here will assure that you have many years of dependable and enjoyable 

service from your LENNOX product.

TAbLE OF CONTENTS

Important Safety Information ............Page  2
Packaging List ...................................Page  3
Introduction ......................................Page  3
General Information ..........................Page  3
Locating Fireplace .............................Page  3
Tools/Supplies Required .................. Page  3
Framing Specifications ..................... Page  4
Fireplace Specifications .................... Page  4
Clearances ....................................... Page  5
Pre-installation ................................. Page  5
Installation Steps ............................. Page  5
Electrical Connections ...................... Page  5
Final Finishing .................................. Page  6
Break-In Period ................................ Page  6
Control Panel Operation ................... Page  6
Remote Control Operation ............... Page  7
Maintenance ..................................... Page  8
Wiring Diagrams .............................. Page  10
Troubleshooting ............................... Page  15
Replacement Parts ........................... Page  16
Optional Accessories ........................ Page  18

Installation must conform to local codes. 

In  the  absence  of  local  codes,  electrical 

wiring  and  grounding  must  comply  with 

the  National  Electrical  Code  ANSI/  NFPA 

70 - latest edition.  In Canada, the current 

CSA C22-1 Canadian Electrical Code - latest 

edition.

GENERAL INFORMATION

Power Supply Wire Specifications

120 Volt, 60 Hz, 1600 Watts:

(ref.

 Page 10)

Hard  Wire  Connection  -  Use  two  conductor, 

non-metallic  sheath  cable  with  ground  wire 

(total  three  wires)  for  the  incoming  power 

supply.  The wire used must conform to local 

and national electrical codes for the specified 

power consumption rating. See Table 1.

240 Volt, 60 Hz, 3000 Watt:

(ref.

 Page 11)

Use three conductor, non-metallic sheath cable 

with  ground  wire  (total  four  wires)  for  the 

incoming power supply. The wire used must 

conform to local and national electrical codes 

for  the  specified  power  consumption  rating. 

See 

Table 1

.

Wall Switch or Wall Thermostat Kits

(optional kits, see 

Page 17)

Low voltage wire is provided for the wall switch 

connection.  The wires gage requirements are 

shown on 

Table 1

.

Figure 1

LOCATING yOUR MERIT PLUS ELECTRIC 

FIREPLACE

Your new fireplace may be installed into existing 

framing or built into a wall (see 

Figure 1)

.

When choosing a location for your new fire-

place, ensure that the general instructions are 

followed.  Also, for the best effect, install the 

fireplace out of direct sunlight and away from 

overhead lighting.  See

 Figure 1

.

fireplace shown in gray.

TOOLS AND bUILDING SUPPLIES

NORMALLy REqUIRED

TOOLS:

Phillips Screwdriver

7/16" Socket Drive

Hammer

Saw And/or Saber Saw

Level

Measuring Tape

Plumb Line

Electric Drill And Bits

Pliers

Square
Gloves

IMPORTANT NOTE: This fireplace system 

is not difficult to install. However, in the 

interest of safety, it is recommended that 

the  installer  be  a  qualified  or  certified 

“tradesman”  familiar  with  commonly 

accepted fireplace installation and safety 

techniques  as  well  as  prevailing  local 

codes.

bUILDING SUPPLIES:

Framing Materials

Wall Finishing Materials

Caulking Materials 

     (noncombustible)

Top View Showing Approved 

Room Locations of Fireplace

Power Supply Wire Gage 

Voltage

Wire Gage

Fuse

120 V

14 GA.

15 AMP

240 V

14 GA.

20 AMP

Wall Switch / Thermostat Wire Gage

Voltage

Wire Gage

5 VOLTS

18 GAGE

Table 1

PACKAGING LIST

This assembled Electric Room Heater is 

packaged with:
•   One  accessory  package  located  in  the 

firebox, containing; 

1. One Installation and Operation Manual.

2. One Warranty Certificate.

3. One Remote Control.

•   Two  spare  Light  Bulbs  are  located  in  a 

recess on the back of the log assembly.

INTRODUCTION

This  Electric  Fireplace  is  designed  for 

residential applications to be framed in as 

a zero clearance fireplace.

This appliance has been tested in accor-

dance  with  UL  2021  and  CSA  C22.2  No. 

46-M198 standards for fixed and location 

dedicated electric room heaters.

Содержание Merit Plus MPE-36R

Страница 1: ...d To assure proper alignment install this fireplace in a squareandplumbcondition usingshimsasnecessary at sides tHIS APPLIANCE IS MOUNTED ON RUBBER FEET TO ENSURE ADEQUATE AIR CIRCULATION BENEATH Fireplace DO NOT BLOCK AIRFLOW AT THE BOTTOM AIR INTAKES Installer do not discard this manual Please leave for the homeowner For your safety Do not store or use gasoline or other flammable vapors and liqu...

Страница 2: ...THIS APPLIANCE OUT DOORS DO NOT EXPOSE FIREPLACE TO THE ELEMENTS SUCH AS RAIN ETC THIS APPLIANCE IS NOT INTENDED FOR USE IN BATHROOMS LAUNDRY AREAS OR SIMILAR INDOOR LOCA TIONS NEVER LOCATE THIS APPLI ANCE WHERE IT COULD FALL INTO A BATHTUB OR OTHER WATER CON TAINER DO NOT RUN ELECTRICAL WIRING OR POWER CORD UNDER CARPETING OR COVER WITH THROW RUGS RUNNERS OR SIMILAR MATERIALS FOR 120 VAC POWER CO...

Страница 3: ...le 1 240 Volt 60 Hz 3000 Watt ref Page 11 Use three conductor non metallic sheath cable with ground wire total four wires for the incoming power supply The wire used must conform to local and national electrical codes for the specified power consumption rating See Table 1 Wall Switch or Wall Thermostat Kits optional kits see Page 17 Low voltage wire is provided for the wall switch connection The w...

Страница 4: ...ss 13 3 4 350 mm 5 1 4 134 mm 24 1 2 622 mm 27 1 2 700 mm 21 1 8 537 mm Electrical Access Cover Power Cord Fireplace specifications Front View Side View 37 1 2 945 mm 26 1 2 38 5 8 668 mm 981 mm 52 3 4 1339 mm 32 812 mm 4 102 mm 15 1 8 384 mm Corner View Electrical left side Junction box Electrical Junction box 38 3 4 984 mm Figure 2 Figure 3 Note Framing dimensions are calculated for a nailing fl...

Страница 5: ...applicable regulations to reduce the risk of fire electrical shock and injury to individuals IMPORTANT Any electrical re wiring of this appliance must be done by a qualified electrician WARNING Do not use this fireplace if any part of it has been underwater Immediately call a qualified servicetechniciantoinspectthe fireplace and replace any part of the electrical system which has been under water ...

Страница 6: ...nd down covering the outlet or glass enclosure panel optional kit There are a wide variety of finished looks for these fireplaces from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings Accent Trim Installations Anoptionalaccenttrimkitisavailablefromyour dealer see Page 18 These options give the appliance an attractive finished look Hearth An aesthetically pleas...

Страница 7: ...t then press the display button C to activate the lights Note If the flame does not come on imme diately adjust brightness and intensity buttons E K 4 Toincreasethebrightness pressandrelease the light brighten button see E Each time you press this button you will hear a beep andthebrightnesswillincreaseslightlyuntil the maximum brightness is achieved To decrease the brightness press and release th...

Страница 8: ...eaners on the glass panel Do not spray liquids directly onto any surface of the fireplace 3 Open the screens remove glass panel enclosure if applicable 4 OPTIONAL To ensure that the brick panel isn t accidentally scratched you may wish to remove it before proceeding Brick Panel Removal Procedure a Remove the 2 screws on the front of the grate Remove Grate see Figure 8 b Lift out Log Ember assembly...

Страница 9: ...in kit 4 Remove the 2 screws on the front of the grate see Figure 12 Also see item 7 on Page 17 Remove Grate 5 Lift out log ember assembly by tilting for ward and firmly pulling on back of ember bed assembly It should pop out from track and lift out Caution Be careful not to scratch the finish 6 Remove spare bulbs from the recess on the back of the log assembly Access bulbs as follows Use gloves o...

Страница 10: ... Page 3 N L1 ground YELLOW AND GREEN ORANGE BLACK BLUE BLUE WHITE N L1 N1 N2 L2 120 v 1600 w 120 v ac ground G If the appliance is to be hard wired in the power cord must be removed see instruction 2 on page 5 Figure 20 WIRING 120 volt Figure 19 L1 Black Power L2 ORANGE Power G Green Ground N White Common N1 BLUE Common N2 BLUE Common HOME POWER SUPPLY 120 VAC Control Panel Flame Ember On Off Swit...

Страница 11: ...mperature Sensor Remote Sensor PTC Heater 1 L Heater 2 L Fan Motor L Flame Motor L Light L L R1 L R2 L FAN L M P L L LIGHT L1 L2 N1 N2 N MAIN POWER L1 L2 N N FLAME L FLAME SIP4 K P SIP2 REMOTE SIP3 K H TEM SIP6 N LIGHT POWER N N FAN N M P TRA SIP11 SIP7 T P LIGHT SIP13 Circuit Board GROUND T105 C HOME POWER SUPPLY 240 VAC 120 VAC 120 VAC WHITE BLACK ORANGE BLUE BLUE YELLOW AND GREEN ground N L1 L2...

Страница 12: ...rams optional kits see Page 18 When using the manual control panel power on off switch the outside power on off switch optional wall switch kit must be in the OFF position When using the outside power on off switch optional wall switch the manual control panel power on off switch must be in the OFF position When using the remote control optional kit the manual control panel power on off switch and...

Страница 13: ... the following information 1 Turn off circuit breaker 2 Remove cover plate located on the left side of appliance 3 Locate the the black and white wires and pull out the length needed to reach wall thermostat 15 feet max 4 Connect the wires to the wall thermostat as shown in Figure 25 Follow instructions provided with wall switch kit Figure 25 Wall Thermostat Black 5 V Left Side of Fireplace White ...

Страница 14: ...Switch per instructions provided with kit and per the following information 1 Turn off circuit breaker 2 Remove cover plate located on the left side of appliance 3 Locate the 2 red wires and pull out the length needed to reach wall switch 15 feet max 4 Connect the red wires to the wall switch as shown in Figure 26 Follow instructions provided with wall switch kit Red Red Figure 26 Red 5V Red Red R...

Страница 15: ...ace the flame motor 3 Dimorpoorlyvisibleflameorlog set and ember is not glowing Light bulb s burnt out or wiring is loose Homeowner Inspect all wiring for loose connec tions and repair or replace if neces sary Inspect light bulbs and replace if necessary 4 Flame sputters Flame motor is defective Qualified service technician Replace flame motor 5 Remote control does not work Low batteries Unit swit...

Страница 16: ...h5043 1 9 Flame Cylinder Assembly H1631 1 10 Flame Motor H1632 1 11 Lennox Logo Kit 1 Each 12L15 1 12 Log Ember Bed Assembly H1634 1 13 Panel Bottom Front H1635 1 14 Panel Flame Cover H1636 1 15 Panel Louver Upper Front H1637 1 16 Panel Upper Frame Top H1638 1 17 Electrical Outlet Cover Plate H1639 1 18 Screen Set Pull H1640 1 19 Switch Toggle 1 Each H1641 1 20 Transformer Assembly H1642 1 21 Wire...

Страница 17: ...SCALE 17 Replacement Parts component diagrams Mpe 36r 8b 23 14 16 11 1 4 2 5 6 6 7 8a 12 13 15 19 17 Front View POWER ON OFF DISPLAY ON OFF Dimmer Brighter EMBERS HEATER ON OFF TEMP CONTROL HIGH MED LOW FLAME HIGHER LOWER 22 20 3 1 9 18 ...

Страница 18: ...it A 41 1041 mm B 31 7 8 810 mm C 34 3 8 872 mm D 36 914 mm E 2 1 2 64 mm A B C D These glass enclosure panels are a one piece panel which have a bi fold look as shown below This kit contains trim panels used to finish the gaps between the wallboardand the fireplace providing the appliance a finished built in look E Cat No Model Description H3606 FFEP 36M 36 DecorativeCompleteFrontFace MissionStyl...

Страница 19: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 19 NOTES ...

Страница 20: ... The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1110 West Taft Avenue Orange CA 92865 ...

Отзывы: