background image

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

9

Replacing Light bulbs

  b.  Flame Cylinder Bulbs 

i.  Remove Brick panel, following proce-

dure on Page 8 (see 

Brick panel Removal 

Procedure

).

Figure 12

Ember bed

Figure 13

Bulb

bulb

Figure 14

Figure 15

Figure 16

Figure 17

Figure 18

Brick panel retain-
ing brackets

Flame
Panel

iii. Locate flame cylinder drum (see

 Figure 

17).

 Squeeze one half of drum cylinder 

until its top edge clears the top drum 

track. Remove the bottom edge of the 

cylinder drum from the bottom drum 

track.  Once  you  have  removed  one 

half of the drum cylinder, you will have 

access to the 2 light bulbs (see 

Figure 

18).    Note:

  do  not  exert  excessive 

pressure on the drum cylinder as this 

may cause damage.  

v.  Lift off spring from bulb tips, then hold 

socket and pull bulb out to remove. 

Install  new  bulbs  into  sockets  by 

pressing  them  in  (while  holding  the 

socket), Install retaining spring over 

each bulb tip.

7. Reinstall all components that were removed 
(reverse 

Steps 1-5)

.

Flame Cylinder Drum

bulbs

bulb Replacement Procedure:

•  2 bulbs provide illumination for the ember 

bed and 2 bulbs provide illumination for the 

flame generation assembly (bulbs are rated at 

35 Watts Max., Halogen, GX6.35).
•  2 spare bulbs are located in a recess on the 

back of the log assembly.

1. Turn off power to the fireplace.

2. Let the fireplace cool, if it has been operat-

ing.

3. (If  optional  glass  panel  enclosure  is 

installed) Remove glass panel per instruc-

tions provided in kit.

4. Remove the 2 screws on the front of the 

grate (see 

Figure 12

. Also see item #7 on 

Page 17

). Remove Grate.

5. Lift out log/ember assembly by tilting for-

ward and firmly pulling on back of ember 

bed  assembly.  It  should  pop  out  from 

track and lift out. Caution: Be careful not 

to scratch the finish.

6. Remove spare bulbs from the recess on 

the back of the log assembly.

  Access bulbs as follows:

Use gloves or cloth when handling bulbs to 

prevent oils from your skin damaging bulbs 

when heated.  

a. Ember Bed Bulbs - 

i.  With  the  ember  bed  removed,  the  2 

ember  bed  light  bulbs  will  be  visible 

(see 

Figures 13 and 14

). 

ii. Lift off spring from bulb tips, then hold 

socket and pull out to remove. Install 

new bulbs into sockets by pressing them 

in  (while  holding  the  socket),  Install 

retaining spring over each bulb tip.  

iii. Plug in power cord or connect power  to 

appliance. Turn on power to test bulbs. 

Disconnect power.

iv. Reverse 

Steps 3 to 5

.

ii. using a phillips screwdriver, remove the 

flame panel (see 

Figure 16)

.

Grate

Log/Ember Assembly

       CAUTION 

Do not touch the bulbs, oils from 

your  skin  will  damage  them 

when they heat up.  Use gloves 

or cloth when handling bulbs.

       CAUTION 

Do  not  exceed  a  35  Watt  bulb.  

Use of a higher rated bulb may 

result in a fire, causing property 

damage, personal injury or loss 

of life. 

       WARNING 

The fireplace must be unplugged/

disconnected  from  the  power 

supply prior to any maintenance 

or cleaning in order to reduce the 

risk electric shock or fire. 

       WARNING 

The halogen light bulbs in your 

fireplace can become extremely 

hot.  Allow  at  least  10  minutes 

between turning off the fireplace 

and removing light bulbs to avoid 

the accidental burning of skin.

 

Содержание Merit Plus MPE-36R

Страница 1: ...d To assure proper alignment install this fireplace in a squareandplumbcondition usingshimsasnecessary at sides tHIS APPLIANCE IS MOUNTED ON RUBBER FEET TO ENSURE ADEQUATE AIR CIRCULATION BENEATH Fireplace DO NOT BLOCK AIRFLOW AT THE BOTTOM AIR INTAKES Installer do not discard this manual Please leave for the homeowner For your safety Do not store or use gasoline or other flammable vapors and liqu...

Страница 2: ...THIS APPLIANCE OUT DOORS DO NOT EXPOSE FIREPLACE TO THE ELEMENTS SUCH AS RAIN ETC THIS APPLIANCE IS NOT INTENDED FOR USE IN BATHROOMS LAUNDRY AREAS OR SIMILAR INDOOR LOCA TIONS NEVER LOCATE THIS APPLI ANCE WHERE IT COULD FALL INTO A BATHTUB OR OTHER WATER CON TAINER DO NOT RUN ELECTRICAL WIRING OR POWER CORD UNDER CARPETING OR COVER WITH THROW RUGS RUNNERS OR SIMILAR MATERIALS FOR 120 VAC POWER CO...

Страница 3: ...le 1 240 Volt 60 Hz 3000 Watt ref Page 11 Use three conductor non metallic sheath cable with ground wire total four wires for the incoming power supply The wire used must conform to local and national electrical codes for the specified power consumption rating See Table 1 Wall Switch or Wall Thermostat Kits optional kits see Page 17 Low voltage wire is provided for the wall switch connection The w...

Страница 4: ...ss 13 3 4 350 mm 5 1 4 134 mm 24 1 2 622 mm 27 1 2 700 mm 21 1 8 537 mm Electrical Access Cover Power Cord Fireplace specifications Front View Side View 37 1 2 945 mm 26 1 2 38 5 8 668 mm 981 mm 52 3 4 1339 mm 32 812 mm 4 102 mm 15 1 8 384 mm Corner View Electrical left side Junction box Electrical Junction box 38 3 4 984 mm Figure 2 Figure 3 Note Framing dimensions are calculated for a nailing fl...

Страница 5: ...applicable regulations to reduce the risk of fire electrical shock and injury to individuals IMPORTANT Any electrical re wiring of this appliance must be done by a qualified electrician WARNING Do not use this fireplace if any part of it has been underwater Immediately call a qualified servicetechniciantoinspectthe fireplace and replace any part of the electrical system which has been under water ...

Страница 6: ...nd down covering the outlet or glass enclosure panel optional kit There are a wide variety of finished looks for these fireplaces from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings Accent Trim Installations Anoptionalaccenttrimkitisavailablefromyour dealer see Page 18 These options give the appliance an attractive finished look Hearth An aesthetically pleas...

Страница 7: ...t then press the display button C to activate the lights Note If the flame does not come on imme diately adjust brightness and intensity buttons E K 4 Toincreasethebrightness pressandrelease the light brighten button see E Each time you press this button you will hear a beep andthebrightnesswillincreaseslightlyuntil the maximum brightness is achieved To decrease the brightness press and release th...

Страница 8: ...eaners on the glass panel Do not spray liquids directly onto any surface of the fireplace 3 Open the screens remove glass panel enclosure if applicable 4 OPTIONAL To ensure that the brick panel isn t accidentally scratched you may wish to remove it before proceeding Brick Panel Removal Procedure a Remove the 2 screws on the front of the grate Remove Grate see Figure 8 b Lift out Log Ember assembly...

Страница 9: ...in kit 4 Remove the 2 screws on the front of the grate see Figure 12 Also see item 7 on Page 17 Remove Grate 5 Lift out log ember assembly by tilting for ward and firmly pulling on back of ember bed assembly It should pop out from track and lift out Caution Be careful not to scratch the finish 6 Remove spare bulbs from the recess on the back of the log assembly Access bulbs as follows Use gloves o...

Страница 10: ... Page 3 N L1 ground YELLOW AND GREEN ORANGE BLACK BLUE BLUE WHITE N L1 N1 N2 L2 120 v 1600 w 120 v ac ground G If the appliance is to be hard wired in the power cord must be removed see instruction 2 on page 5 Figure 20 WIRING 120 volt Figure 19 L1 Black Power L2 ORANGE Power G Green Ground N White Common N1 BLUE Common N2 BLUE Common HOME POWER SUPPLY 120 VAC Control Panel Flame Ember On Off Swit...

Страница 11: ...mperature Sensor Remote Sensor PTC Heater 1 L Heater 2 L Fan Motor L Flame Motor L Light L L R1 L R2 L FAN L M P L L LIGHT L1 L2 N1 N2 N MAIN POWER L1 L2 N N FLAME L FLAME SIP4 K P SIP2 REMOTE SIP3 K H TEM SIP6 N LIGHT POWER N N FAN N M P TRA SIP11 SIP7 T P LIGHT SIP13 Circuit Board GROUND T105 C HOME POWER SUPPLY 240 VAC 120 VAC 120 VAC WHITE BLACK ORANGE BLUE BLUE YELLOW AND GREEN ground N L1 L2...

Страница 12: ...rams optional kits see Page 18 When using the manual control panel power on off switch the outside power on off switch optional wall switch kit must be in the OFF position When using the outside power on off switch optional wall switch the manual control panel power on off switch must be in the OFF position When using the remote control optional kit the manual control panel power on off switch and...

Страница 13: ... the following information 1 Turn off circuit breaker 2 Remove cover plate located on the left side of appliance 3 Locate the the black and white wires and pull out the length needed to reach wall thermostat 15 feet max 4 Connect the wires to the wall thermostat as shown in Figure 25 Follow instructions provided with wall switch kit Figure 25 Wall Thermostat Black 5 V Left Side of Fireplace White ...

Страница 14: ...Switch per instructions provided with kit and per the following information 1 Turn off circuit breaker 2 Remove cover plate located on the left side of appliance 3 Locate the 2 red wires and pull out the length needed to reach wall switch 15 feet max 4 Connect the red wires to the wall switch as shown in Figure 26 Follow instructions provided with wall switch kit Red Red Figure 26 Red 5V Red Red R...

Страница 15: ...ace the flame motor 3 Dimorpoorlyvisibleflameorlog set and ember is not glowing Light bulb s burnt out or wiring is loose Homeowner Inspect all wiring for loose connec tions and repair or replace if neces sary Inspect light bulbs and replace if necessary 4 Flame sputters Flame motor is defective Qualified service technician Replace flame motor 5 Remote control does not work Low batteries Unit swit...

Страница 16: ...h5043 1 9 Flame Cylinder Assembly H1631 1 10 Flame Motor H1632 1 11 Lennox Logo Kit 1 Each 12L15 1 12 Log Ember Bed Assembly H1634 1 13 Panel Bottom Front H1635 1 14 Panel Flame Cover H1636 1 15 Panel Louver Upper Front H1637 1 16 Panel Upper Frame Top H1638 1 17 Electrical Outlet Cover Plate H1639 1 18 Screen Set Pull H1640 1 19 Switch Toggle 1 Each H1641 1 20 Transformer Assembly H1642 1 21 Wire...

Страница 17: ...SCALE 17 Replacement Parts component diagrams Mpe 36r 8b 23 14 16 11 1 4 2 5 6 6 7 8a 12 13 15 19 17 Front View POWER ON OFF DISPLAY ON OFF Dimmer Brighter EMBERS HEATER ON OFF TEMP CONTROL HIGH MED LOW FLAME HIGHER LOWER 22 20 3 1 9 18 ...

Страница 18: ...it A 41 1041 mm B 31 7 8 810 mm C 34 3 8 872 mm D 36 914 mm E 2 1 2 64 mm A B C D These glass enclosure panels are a one piece panel which have a bi fold look as shown below This kit contains trim panels used to finish the gaps between the wallboardand the fireplace providing the appliance a finished built in look E Cat No Model Description H3606 FFEP 36M 36 DecorativeCompleteFrontFace MissionStyl...

Страница 19: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 19 NOTES ...

Страница 20: ... The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1110 West Taft Avenue Orange CA 92865 ...

Отзывы: