background image

0

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

FIREPLACE FRAMING SPECIFICATIONS

Never  use  galvanized  or  plastic  pipe.    Refer 

to 

Table 7 

 for proper sizing of the gas sup-

ply line, if black iron pipe is being used. Gas 

lines must be routed, constructed and made 

of materials that are in strict accordance with 

local codes and regulations.   We recommend 

that a qualified individual such as a plumber or 

gas fitter be hired to correctly size and route 

the gas supply line to the appliance. Installing 

a gas supply line from the fuel supply to the 

appliance involves numerous considerations of 

materials, protection, sizing, locations, controls, 

pressure, sediment, and more. Certainly no one 

unfamiliar and unqualified should attempt sizing 

or installing gas piping.

Schedule  40

Black Iron Pipe

Inside Diameter (Inches)

Schedule  40 Pipe

Length (feet)

Natural

Gas

Propane

Gas

0-10

1/2

3/8

10-40

1/2

1/2

40-100

1/2

1/2

100-150

3/4

1/2

150-200

3/4

1/2

Table 7

•  A pipe joint compound rated for gas should be 

used on the threaded joints. 

Ensure propane 

resistant compounds are used in propane 

applications

.  Be  very  careful  that  the  pipe 

compound does not get inside the pipe.

•  It is recommended to install a sediment trap 

in the supply line as close as possible to the 

appliance.  Appliances using Propane  should 

have a sediment trap at the base of the tank.

•  Check with local building official for local code 

requirements (i.e. are below grade penetrations 

of the gas line allowed?, etc).

IMPORTANT: If propane is used, be aware that 

if tank size is too small (i.e. under 100-lbs, if 

this is the only gas appliance in the dwelling. 

Ref. NPFA 58), there may be loss of pressure, 

resulting in insufficient fuel delivery (which 

can result in sooting,  severe delayed ignition 

or other malfunctions). Any damage resulting 

from an improper installation, such as this, is 

not covered under the limited warranty.

Proper Sizing of Gas Line

Properly  size  and  route  the  gas  supply  line 

from the supply regulator to the area where the 

appliance is to be installed per requirements 

outlined in the National Fuel Gas Code, NFPA 

54 - latest edition (USA) or CAN/CSA-B149.1 

- latest edition (Canada). 

Notes:

•  All  appliances  are  factory-equipped  with  a 

flexible gas line connector and 1/2 inch shutoff 

valve (see 

Figure 37

 on 

Page 24 

).

•  See 

Massachusetts Requirements

 on 

Page 4

  

for additional requirements for installations in 

the state of Massachusetts in the USA.

•  The gas supply line should Not be connected 

to the appliance until 

Step 6

 (

Page 24 

).

Figure 13 - Corner Framing with Horizontal Termination

Inches

(millimeters)

C

Back wall of chase/enclosure

(including any finishing materials)

D

E

A

B

7 (78)

.

o

N

l

e

d

o

M

A

B

D

E

MLDVT-40

MLDVT-35

35 1/4 57 1/2

40 5/8

28 3/4

in.

895

1461

1032

730

mm

40 1/4

1022

61 13/16

1554

43 11/32

1101

30 11/16

779

in.

mm

C

13 3/4

349

15 1/8

384

in.

mm

MLDVT-30

30 1/4

768

53 3/16

1350

37 29/32

963

26 13/16

681

12 1/4

311

MLDVT-45

in.

mm

45 1/4

1149

66 1/8

1680

46 1/16

1170

32 5/8

829

16 1/2

419

Содержание Merit MLDVT-45NE

Страница 1: ...FE DIRECT VENT MLDVT 30 35 40 45 SERIES Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not light any ap...

Страница 2: ...owing vent com ponents only Secure Vent Direct Vent System Compo nents Secure Flex Flexible Vent Components manufactured by Security Chimneys Inter national and Z FLEX Model GA Venting Systems listed...

Страница 3: ...pane tanks are at pressures that will cause damage to valve components Verify that the tanks have step down regulators to reduce the pressure to safe levels Do not use these appliances if any part has...

Страница 4: ...re Tap Manifold Burner Stage Terminal Ground TP PILOT OUT VENT LO TH TP TH TP HI IN IN Regulator Mounting Screw Cold Climate Insulation For cold climate installations seal all cracks around the applia...

Страница 5: ...bustible and combustible exterior sidewall This distance may be decreased to 2 5 mm for non combustible exterior sidewalls only if the SV4 5HT 2 termination is used Be aware that this is a heat produc...

Страница 6: ...e c n a r a e l C H y l b m e s s a r o t a l u g e r r e t e m t e e f 5 f o t h g i e h a n i h t i w m c 9 t e e f 3 y l b m e s s a r o t a l u g e r r e t e m e h t e v o b a t e e f 5 f o t h g...

Страница 7: ...sides as detailed inTable6 withthefollowingexception When the unit is installed with one side flush with a wall the wall on the other side of the unit must not extend beyond the front edge of the unit...

Страница 8: ...box floor securing the glass door Remove the door by tilting it outward at the bottom and lifting it up Set the door aside protecting it from inadvertent damage See Figure 46 on Page 30 TYPICAL INSTAL...

Страница 9: ...P VENT WITH ONE 90 ELBOW Framing should be constructed of 2x4 or larger lumber Inches mm D 30 D is the required framing depth dimension when the finish material drywall thickness is 2 in 3mm A 2 Frami...

Страница 10: ...rlocalcode requirements i e arebelowgradepenetrations of the gas line allowed etc IMPORTANT Ifpropaneisused beawarethat if tank size is too small i e under 100 lbs if this is the only gas appliance in...

Страница 11: ...ructions should be used as a guideline and do not supersede local codes in any way Install vent according to local codes theseinstructions thecurrentNational Fuel Gas Code ANSI Z223 1 in the USA or th...

Страница 12: ...5 5 5 5 2 6 4 0 1 2 0 0 3 7 5 5 7 4 0 0 1 1 0 2 6 6 5 2 5 0 2 2 0 0 4 5 7 6 5 2 6 5 0 0 3 0 0 3 9 6 5 7 5 0 0 0 2 0 2 2 7 6 1 0 3 0 0 4 5 3 7 5 2 1 6 1 0 0 2 0 3 5 9 7 5 2 6 6 0 1 0 2 0 3 1 8 5 7 6 0...

Страница 13: ...are available in net lengths of 4 1 2 114 mm 10 1 2 267 mm 22 1 2 572 mm 34 1 2 876 mm and 46 1 2 1181 mm Refer to the Vent Section Length Charts on Page 12 for an aidinselectinglengthcombinations El...

Страница 14: ...supplied with the flashing over the vent flashing joint See Figure 21 Loosen the storm collar screw Slide collar down until it meets the top of the flashing Tighten the ad justingscrew Applynon combus...

Страница 15: ...ERE AN ELBOW IS THE ONLY VERTICAL COMPONENT IN THE SYSTEM See Figure 29 uWhenusingSecureFlex useFirestop Spacer SF4 5VF uCeiling Firestop Spacer SV4 5VF A Vent Restrictor as shown in Figure 14 Page 11...

Страница 16: ...2 3 0 914 20 6 096 4 1 219 H H1 20 feet 6 096 m Max V V1 H H1 60 ft 18 3 m Max Figure 25 Top Vent three elbows VERTICAL VENT FIGURES TABLES CONTINUED Horizontal Outside Wall Termination System Figure...

Страница 17: ...ously connected vent sections See Figure 17 on Page 13 I Continue installation of horizontal inclined sections Continue with the installation of the straightventsectionsinhorizontal inclinedrun as des...

Страница 18: ...nations have been designed to perform in a wide range of weather condi tions Our terminations meet or exceed industry standards When selecting the locations of your horizontal terminations do not plac...

Страница 19: ...S THE ONLY VERTICAL COMPONENT IN THE SYSTEM See Figure 29 Use Table 10 as an aid in venting component selection for a particular range of exterior wall thicknesses HORIZONTAL VENT FIGURES TABLES Figur...

Страница 20: ...6 096 m Max Figure 31 Top Vent TWO 90 DEGREE ELBOWS See Table 10 on Page 19 as an aid in venting component selection for a particular range of exterior wall thicknesses HORIZONTAL VENT FIGURES TABLES...

Страница 21: ...Figure 29 V H H V vWall Firestop Spacer SV4 5HF uCeiling Firestop Spacer SV4 5VF uWhen using Secure Flex use Firestop Spacer SF4 5VF vWhen using Secure Flex use Firestop Spacer SF4 5HF vWall Firestop...

Страница 22: ...mperature sealant Catalog No 10K81 to the inner adapter collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent pipe 4 Slidetheinnerflexpipeovertheadaptercol lar Ensure th...

Страница 23: ...he electrical inlet cover plate from the side of the unit by removing the plate s securing screws See Figure 12 on Page 9 3 Removethe coverplate sknockoutandthen feedthepowersupplywirethroughtheknocko...

Страница 24: ...artment Accessthevalvecompartmentbyremovingthe lower control compartment panel see Figure 38 by lifting and pulling the panel forward The panel is mounted on supporting tabs at the extreme right and l...

Страница 25: ...e gas lines are tested and leak free be sure to rinse off the leak testing solution D Observe the individual tongues of flame on the burner Make sure all ports are open and producing flame evenly acro...

Страница 26: ...ted Dis tribute these pieces over the surface of the burner as shown in Figures 44 and 45 Do not use more than is necessary Ensure that the main burner slots remain uncovered by the ember material Pos...

Страница 27: ...35 H7666 WARNING Logs get very hot and will remain hot up to one hour after gas supply is turned off Handle only when logs are cool Left Rear Log Bracket Right Rear Log Bracket Rockwool Do Not Place...

Страница 28: ...ot Place Rockwool Over Burner Slots Log Rack Volcanic Stone Right Rear Log Bracket 1 Position on the left rear log bracket 4 2 3 Position the left front log 2 and the right front log 3 against the log...

Страница 29: ...29 NOTES...

Страница 30: ...with the bottom of the door held away from the fireplace Figure 46 Hook the top flange of the door frame over the top of the firebox frame 6 Let the bottom of the door frame swing gentlyintowardsthefi...

Страница 31: ...ont glass panel are in place and sealed during adjustment 1 Locate adjustment rod and adjust air shutter to the standard set ting as shown in Figure 49 adjustment rod is located in the lower control c...

Страница 32: ...7 7 B F 5 4 V S e l b a t s u j d A 2 1 2 1 o t 2 1 7 g n i h s a l F 1 8 L 7 7 6 C S 5 4 V S 6 s r a l l o C m r o t S x o b s r a l l o c 6 4 2 2 H F H 5 4 V S k c a p 0 1 r e c a p S p o t s e r i...

Страница 33: ...o f n i m r e T l a c i t r e V x e l F h t i w 2 1 6 o t t a l f d i g i r f o n o i t c e s r e t p a d A r a l l o c t r o p p u s f o o r t n e v d n a g n i h s a l f f o o r y l b m e s s a r a...

Страница 34: ...on kit when performing any gas conversion Gas Conversion Kits Warning This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructionsandallappli...

Страница 35: ...o pressure regula tor mounting screws Remove the pressure regulatoranddiaphragm Discardallremoved components Ensure the provided diaphragm is installed properly onto the replacement pressure regulator...

Страница 36: ...pe joint compounds on flare fittings PILOT OUT VENT LO TH TP TH TP HI IN IN Pilot Stage Terminal Pressure Tap Inlet Pilot Gas Outlet Supply Gas Inlet Pressure Tap Manifold Burner Stage Terminal Ground...

Отзывы: