Setting Humidity Controls
NOTICE
Humidifier and dehumidifier controls must be setup by the installer or
these controls will not be visible. If your system has one or both of
these features and the controls are not visible, contact your Lennox
dealer for proper setup.
If the controls have been setup, they will appear and will be ON.
Heating Mode
: When a XP25 heat pump is installed, the option
heating
mode
is displayed. To adjust heating mode, touch the
button to go to the
Feature screen; then
select system
settings button. Touch the heating
mode icon to toggle between
NORMAL
and
COMFORT
. Default is
NORMAL
.
Normal
— Standard system operation
Comfort
— The system reduces indoor airflow which increases supply
air temperature.
Humidification and Dehumidification Settings
: To adjust humidify con
trols (humidifier), click the
button to go to the Feature screen; then
select
system
settings button. Some systems may have a humidifier and some
may have a dehumidifier, while still other systems may have both (as shown
in figure 35). You can control either or both from this screen.
Humidification Settings
: Touch the button of the humidifier setting you
want to address; if it says humidifier is OFF, one touch will change it to ON
and bring on the
set-to
button. When you touch the
set-to
button, the arrows
appear, allowing you to change to the desired humidity setting.
Dehumidification Controls (icomfort™-enabled Outdoor Unit)
: Touch
the button of the humidifier controls you want to address; if it says ClimateIQ
setting DRY (off), one touch will display a selection for DRY, MODERATE
and HUMID. Selecting MODERATE or HUMID will bring on the
set-to
but
ton. When you touch the
set-to
button, the arrows appear, allowing you to
change to the desired humidity setting.
Three climate settings are available:
Dry
The system supplies higher indoor airflow at all compressor ca
pacities, increasing efficiency by operating at a higher sensible to total
ratio.
Moderate
The system supplies indoor airflow that balances effi
ciency and comfort.
Humid
The system supplies lower indoor airflow at all compressor
capacities, improving humidity removal by operating at a lower sens
ible to total ratio.
SYSTEM SETTINGS
current indoor humidity is 50%
heating
mode
COMFORT
humidifier
is ON
ClimateIQ
setting
MOD
40
%
set to
50
%
set to
ALL CHANGES MADE ON
THIS SCREEN ARE IN
STANTLY SAVED.
9:39 am January 23, 2012
?
Wi-Fi
DRY
MODERATE
HUMID
humidifier
display
is ON
(default is ON)
humidification
settings
dehumidification
settings
Figure 35. Humidification Settings
(icomfort™-enabled Outdoor Unit)
Dehumidification Controls (Non-communicating Outdoor Unit)
: Touch
the button of the humidifier settings you want to address; if it says de-humidi
fier
OFF
, one touch will display a selection for
OFF
,
MEDIUM
and
HIGH
. Se
lecting
MEDIUM
or
HIGH
will bring on the
set-to
button. When you touch the
set-to
button, the arrows appear, allowing you to change to the desired hu
midity setting.
Three climate settings are available:
OFF
The system supplies higher indoor airflow at all compressor ca
pacities, increasing efficiency by operating at a higher sensible to total
ratio.
MEDIUM
The system supplies indoor airflow that balances efficiency
and comfort.