![Lennox HSXA19 SERIES Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/lennox/hsxa19-series/hsxa19-series_installation-instructions-manual_1876910008.webp)
Page 8
Refrigerant Line Sets
How To Install Vertical Runs
(new construction shown)
PVC Pipe
Fiber Glass
Insulation
Caulk
Outside Wall
Vapor Line
(wrapped with Armaflex)
Liquid Line
IMPORTANT - Refrigerant
lines must not contact
structure.
Outside Wall
Inside Wall
Liquid Line
Vapor Line
IMPORTANT - Refrigerant
lines must not contact wall.
Wood Block
Between Studs
Strap
Sleeve
Wood Block
Strap
Sleeve
Wire Tie
Wire Tie
Wire Tie
NOTE - Similar installation practices should be used if
line set is to be installed on exterior of outside wall.
Figure 7