TABLE 11
NORMAL OPERATING PRESSURES
MODE/
OUTDOOR COIL
HP27-024
HP27-030
HP27−036
HP27-042
MODE/
TYPE OF
EXPANSION
OUTDOOR COIL
AIR ENTERING
TEMPERATURE
F
LIQ.
+10
PSIG
SUC.
+5
PSIG
LIQ.
+10
PSIG
SUC.
+5
PSIG
LIQ.
+10
PSIG
SUC.
+5
PSIG
LIQ.
+10
PSIG
SUC.
+5
PSIG
65
134
82
136
80
137
80
134
75
Cooling
75
159
83
161
81
163
81
167
76
Cooling
TXV
O l
85
186
84
188
82
190
82
199
77
TXV
Only
95
216
83
217
83
221
83
232
78
y
105
248
86
251
85
257
85
257
80
20
179
36
173
36
177
33
184
29
Heating
30
188
49
192
49
195
40
194
39
Heating
40
203
58
205
58
208
46
205
48
50
228
65
218
65
217
58
216
58
VI−MAINTENANCE
At the beginning of each heating or cooling season, the
system should be cleaned as follows:
A−Outdoor Unit
1 − Clean and inspect outdoor coil. (Coil may be flushed
with a water hose).
2 − Visually inspect all connecting lines, joints and coils
for evidence of oil leaks.
IMPORTANT
If insufficient heating or cooling occurs, the unit
should be gauged and refrigerant charge
checked.
B−Indoor Coil
1 − Clean coil if necessary.
2 − Check lines and coil for evidence of oil leaks.
3 − Check condensate line and clean if necessary.
C−Indoor Unit
1 − Clean or change filters.
2 − Adjust blower cooling speed. Static pressure drop
over coil should be checked to determine correct
blower CFM. Refer to Lennox Engineering Hand-
book.
3 − Belt Drive Blowers-Check condition and tension.
4 − Check all wiring for loose connections.
5 − Check for correct voltage at unit.
6 − Check amp−draw on blower motor.
Unit nameplate_________Actual_________.