HP25 UNIT DIMENSIONS-INCHES (MM)

HP25

HEAT PUMP UNIT

23/4

(70)

COMPRESSOR

INLET

INLET

AIR

TOP VIEW

SIDE VIEW

FRONT VIEW

ELECTRICAL

INLETS

VAPOR

LINE INLET

(HP25211460)

LIQUID

LINE INLET

(HP25510650)

DISCHARGE

AIR

COIL DRAIN

OUTLETS

(Around perimeter

of base)

4

(102)

C

D

F

13/8

(35)

J

LIQUID

LINE INLET

(HP25211460)

VAPOR

LINE INLET

(HP25510650)

E

4

(102)

61/16

(154)

 AIR

INLET

 AIR

A

B

G

H

H

L

L

K

K

47/8 (22)

Model No.

A

B

C

D

E

F

G

H

J

K

L

HP25211

in.

277/8

257/8

297/8

121/4

227/16

147/16

221/8

17/8

163/4

51/2

27/8

HP25211

HP25261

mm

708

657

759

311

570

367

562

48

425

140

73

HP25311

in.

307/8

321/8

341/16

123/4

265/8

185/8

281/8

2

171/4

71/2

37/8

HP25 311

HP25411413 mm

784

816

865

324

676

473

714

51

438

191

98

HP25 461 463

in.

347/8

321/8

341/16

133/4

265/8

185/8

281/8

2

181/4

71/2

37/8

HP25461463

mm

886

816

865

349

676

473

714

51

464

191

98

HP25511513 in.

447/8

321/8

341/16

291/4

265/8

185/8

281/8

2

203/4

71/2

37/8

HP25 511 513

HP25651653 mm

1140

816

865

743

676

473

714

51

527

191

98

Содержание HP-511-513

Страница 1: ...evied for non compliance INSTALLATION INSTRUCTIONS HP25 SERIES UNITS HEAT PUMP UNITS 503 302M 6 95 Supersedes 503 247M TABLE OF CONTENTS HP25 HEAT PUMP UNIT 1 SHIPPING AND PACKING LIST 1 GENERAL INFOR...

Страница 2: ...D E F G H J K L HP25 211 in 27 7 8 25 7 8 29 7 8 12 1 4 22 7 16 14 7 16 22 1 8 1 7 8 16 3 4 5 1 2 2 7 8 HP25 211 HP25 261 mm 708 657 759 311 570 367 562 48 425 140 73 HP25 311 in 30 7 8 32 1 8 34 1 16...

Страница 3: ...OTE 48 1219mm clearance required on top of unit One side dimension may be 12 305mm 36 914mm 36 914mm 36 914mm 36 914mm Heat pump units operate under a wide range of weath er conditions therefore sever...

Страница 4: ...is instruction see figure 6 and in indoor unit instructions Refer to figure 5 for thermostat designa tions Refer to unit rating plate for minimum circuit am pacity and maximum fuse size WARNING Unit m...

Страница 5: ...1 1 8 in 28 6 mm FIELD FABRICATED L15 LINE SETS L15 41 20 ft 50 ft 6 1 m 15 2 m L15 65 30 ft 50 ft 9 1 m 15 2 m FIELD FABRICATED L15 26 20 ft 50 ft 6 1 m 15 2 m NOTE To obtain maximum efficiency remov...

Страница 6: ...o produce substances that corrode copper piping and compressor parts 1 Connect manifold gauge set to the service valve ports as follows low pressure gauge to vapor line service valve high pressure gau...

Страница 7: ...and suc tions pressures do not perform normally follow the steps below to correctly phase in the unit 1 Disconnect power to the unit 2 Reverse any two field power leads to the unit 3 Reapply power to...

Страница 8: ...6 If ambient temperature is less than 60 F 15 C air flow might need to be restricted to achieve pressur es in the 200 250 psig 1379 1724 kPa range See figure 8 These higher pressures are necessary for...

Страница 9: ...ngle pole single throw which is located on the liquid line The switch shuts off the compressor when discharge pressure rises above the factory set ting The switch is normally closed and is permanently...

Страница 10: ...PS2 termi nals on the defrost board If using an additional pres sure switch remove jumper before connecting additional switch to control board If no additional switch is needed DO NOT REMOVE JUMPER U...

Страница 11: ...power supplies At the beginning of each heating or cooling season the system should be cleaned as follows Heat Pump Unit 1 Clean and inspect outdoor coil Coil may be flushed with a water hose 2 Outdo...

Страница 12: ...o City City Serial No Date State State Service Technician Amps Supply Outdoor Fan Compressor Indoor Filter Clean Indoor Blower RPM Electrical Connections Tight Supply Voltage Unit Off S P Drop Over Ev...

Отзывы: