NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

15

Figure 42

Figure 43

THIS FIREPLACE IS NOT INTENDED TO BE
USED AS A SUBSTITUTE FOR A FURNACE TO
HEAT AN ENTIRE HOME.  USE FOR SUPPLE-
MENTARY HEATING ONLY.

HOUSE
WIRING

COVER PLATE
Replace Cover Plate
After Electrical
Hook-Up

POWER TO THE FIREPLACE
The Optional Blower Kit
Operates on 115 volt 60 Hz
150 watts AC

GROUND
WIRE

House Wiring Must Be Secured
With The Appropriate Electrical
Connector To The Fireplace
Convenience Outlet Wiring

The FBK-100/200 Blower Kits are design certi-
fied by Warnock Hersey for use with these
appliances.

Always check local building codes.  Installation
of the FBK Blower Kits must comply with local
regulations as well as the National Electric
Code.

Combustion Air Kits

These appliances are equipped with an outside
(make-up) air door and integral actuator arm.  If
the appliance is to be installed with an outside air
vent system, use only FireCraft Models FAOK-4
or FAOK-4LD Combustion Air Kits.  These kits
come complete with detailed installation instruc-
tions and all components necessary in complet-
ing a combustion air vent system.

Figure 44

To operate, push the end of the actuator to the
left as shown in 

Figure 44, until it "pops" free of

its "locked" position.  Pull the actuator forward
to open the combustion air door, and push it
back to close.  To "lock" the combustion air door
closed, ensure the actuator is pushed all the
way back then push the end of the actuators to
the right until the step in the actuator moves
behind the appliance front face within the slot-
ted opening.

Operate the actuator through several cycles
including the "lock position.  Ensuring proper
operation and freedom of movement.  Return
the actuator arm to the locked position.

Gas Line Connection

Install a 

¹⁄₂

" gas supply line through fireplace

wall for connection to a decorative gas appli-
ance inside the firebox.  Outside, the gas supply
line connects to a gas shut-off valve recessed
flush into the wall or floor. The valve should be
controlled by a removable valve key for safety.

Always plumb gas line installation per local
codes. Check all connections and test for gas
leaks, using a gas leak test solution (also
referred to as bubble leak solution).

After completing the installation of the optional
combustion air vent system the actuator arm
must be put in service and tested to ensure
proper operation before completing any enclo-
sure around the firebox.  Failure to do so may
result in extensive and costly rework.

Locate the actuator arm along the right side of
the appliance firebox opening and refer to
Figure 44.

Note:  Using a soapy water solution (50% dish
soap, 50% water) is an effective leak test
solution but it is not recommended, because
the soap residue that is left on the pipes/
fittings can result in corrosion over time.  Never
use an open flame to check for leaks.

This provision is intended for connection to a
decorative gas appliance incorporating an au-
tomatic shut-off device and complying with the
Standard for Decorative Gas Appliances for
installation in vented fireplaces, ANSI Z21.60
(1991) or American Gas Association draft re-
quirements for Gas-Fired Log Lighters for Wood
Burning Fireplaces, Draft No. 4 dated August,
1993. Install in accordance with the National
Fuel Gas Code, ANSI Z223.1. This complies
with the revised U.L. 127 standard.

Vent Free Appliances

This unit has been tested and approved to
ANSI/IAS/AGA Z21.11.2 for use with unvented
gas appliances and complies with the stan-
dard for Factory-Built fireplaces, UL 127, when
installed with unvented gas log sets.  Special
instructions with regards to mantle installa-
tions must be taken into consideration when
installing such appliances.

The unit has been tested for use with any
unvented log sets having a maximum rating of
32,000 BTU.  The minimum mantle configura-
tion for these log sets are outlined in 

Figure 46.

Log sets with 40,000 BTU may be installed
provided that no combustible mantle projec-
tions are placed lower than 18 inches from the
fireplace opening.

These fireplaces have been marked with a
maximum rating of 32,000 BTU to assure that
homeowners do not exceed the allowable lim-
its for all allowed installations of mantles.  That
limit may be increased to 40,000 BTU, pro-
vided that the mantle installed complies with
the 18-inch limitation and a copy of these
instructions are available.

NEVER INSTALL AN UNVENTED GAS LOG
SET WITH A BTU GREATER THAN 32,000 IF
COMBUSTIBLE MANTLE PROJECTIONS ARE
LOWER THAN 18 INCHES ABOVE THE FIRE-
PLACE  OPENING.

CAUTION: WHEN USING THE DECORATIVE
GAS APPLIANCE, THE FIREPLACE DAMPER
MUST BE SET IN THE FULLY OPEN POSITION.

CAUTION: PLUMBING CONNECTIONS SHOULD
ONLY BE PERFORMED BY A QUALIFIED, LI-
CENSED PLUMBER. MAIN GAS SUPPLY MUST
BE OFF WHEN PLUMBING GAS LINE TO FIRE-
PLACE OR PERFORMING SERVICE.

BLOWER THREE
PRONGED PLUG TO
GROUNDED OUTLET

Combustion
Air Actuator

Pull Forward to Open,
Push Back to Close

Содержание HC-42

Страница 1: ...modify the fireplace or its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the fireplace chimney components and accessories may...

Страница 2: ...damage as a result of handling or transporta tion These items should be inspected by your distributor or qualified factory representative to ensure safe condition When in doubt con sult your distribu...

Страница 3: ...These fireplace systems are designed for in stallation in accordance with the National Fire Protection Standard for chimneys fireplaces and solid fuel burning appliances NFPA 211 and in accordance wit...

Страница 4: ...overhead obstructions such as trees power lines etc A chase should be constructed and insulated just like any outside wall In a cold climate we recommend the base of the chase should also be insulate...

Страница 5: ...l safety strips beneaththefireplaceasillustrated Figures6 7 and 8 The safety strips should overlap for continual coverage of the floor Note Safety strips are not required when fire place rests on a no...

Страница 6: ...ce If a wall covering such as drywall is to be attached to the rear wall then the 23 606 mm must be measured from the drywall surface It is important that this dimension be exact If the appliance is t...

Страница 7: ...der Fireplace Framing B A A Outside Chase G H Back Wall of Chase Enclosure Including Finising Materials if any Rough Framing Face Unfinished Shown FOAK Combustion Air Kit Optional Corner Installation...

Страница 8: ...upthroughtheceiling or floor joists to an outside wall The air duct s inlet should be located above any anticipated snow level Note If the fireplace is installed against an inside wall the Class 0 me...

Страница 9: ...sure proper engagement Checkverticalalignmentofchim ney so that it projects from the roof in true vertical position Figure 27 Step 4 Note Chimney sections are con structed with a unique locking tab de...

Страница 10: ...Do not overtighten as this might dam age the chimney section refer to Figure 31 Note If chimney extends more than 8 above roof surface guy wires are also recommended Use three 3 guy wires attach to l...

Страница 11: ...fireplace system is 15 0 The maxi mum height is 60 0 To determine the number of chimney sections and chimney components required follow these steps 1 Determine total vertical height of the fireplace i...

Страница 12: ...23 0 1 0 1 5 278 23 2 0 0 0 6 282 23 6 0 1 1 5 288 24 0 1 0 0 6 294 24 6 0 1 0 6 298 24 10 2 0 0 6 304 25 4 1 1 0 6 312 26 0 0 0 1 6 322 26 10 1 0 1 6 324 27 0 0 0 0 7 328 27 4 0 1 1 6 334 27 10 1 0 0...

Страница 13: ...35 69 1 0 0 1 0 1 37 73 1 0 0 2 1 0 38 75 1 0 0 0 2 0 39 77 1 0 2 1 1 0 41 80 1 0 1 4 0 0 43 83 1 0 1 0 2 0 44 85 1 0 0 0 1 1 45 87 1 0 0 3 1 0 46 89 1 0 0 1 2 0 48 91 1 0 2 0 2 0 49 94 1 0 1 0 1 1 50...

Страница 14: ...mney section Step 2 Center inner slip section into inner flue pipe slip down Step 3 Center outer locking section over outer chimneypipe Pushdownuntillockingjointhas firmly engaged Step 4 Pull up sligh...

Страница 15: ...per operation before completing any enclo sure around the firebox Failure to do so may result in extensive and costly rework Locate the actuator arm along the right side of the appliance firebox openi...

Страница 16: ...LACE IF THE FIREPLACE HAS BEEN FACED WITHNONCOMBUSTIBLEMATERIALS THERE MIGHT NOT BE SUFFICIENT CLEARANCE TO INSTALL THE GLASS DOORS OF YOUR CHOICE ENSURE ADEQUATE CLEARANCE IS MAINTAINED AT ALL TIMES...

Страница 17: ...5 6 56 6 1 2 Wonderboard 3 23 31 7 51 7 1 2 Super Firetemp M Johns Manville 61 1 64 1 42 1 3 8 Super Firetemp L Johns Manville 54 1 85 Face brick 9 00 111 20 93 20 7 8 Common brick 5 00 20 Cement mort...

Страница 18: ...ptable combinations of materialsbecause Rvalues areadditivewhere r and k values are not R value 1 k r x thickness of material used Example Given that the required R value for a suitable floor protecto...

Страница 19: ...Chase Termination Square 63L48 FTF8 CT1 Firestop Spacer Flat 63L31 F8FS 2 Locking Band 63L60 FLB Forced Air Blower Kits Single Speed 80L84 FBK 100 Variable Speed 80L85 FBK 200 FBK 200 Models Only Outs...

Страница 20: ...ign materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1110 West Taft Avenue Orange CA 92865 Chase Termina...

Отзывы: