Page 4
TABLE 1
G71MPP−36B−070 BLOWER PERFORMANCE
(less filter)
0 through 0.80 in. w.g. External Static Pressure Range
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Heating Input Range and Blower Volume − CFM
40%
50%
60%
70%
80%
90%
100%
Increase (+15%) Heat CFM
535
610
690
770
870
975
1075
Increase (+7.5%) Heat CFM
505
575
645
720
810
905
1000
Default Heat CFM
480
545
610
675
760
845
930
Decrease (–7.5% ) Heat CFM
460
520
580
640
715
790
870
Decrease (–15% ) Heat CFM
440
490
540
590
655
715
780
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
Blower Speed Selections
First Stage Cool Speed − cfm
Second Stage Cool Speed − cfm
Low
Medium−
Low
Medium
High
High
(Default)
Low
Medium−
Low
Medium
High
High
(Default)
Increase (+10%) Cool CFM
730
815
865
935
1015
1190
1280
1395
Default Cool CFM
680
755
795
855
930
1065
1155
1270
Decrease (–10%) Cool CFM
625
695
730
775
830
950
1010
1105
The effect of static pressure is included in air volumes shown.
Lennox Harmony III
t
Zone Control Applications − Minimum blower speed is 250 cfm.
The following control board configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Mode
(Heating Blower Performance Table):
With a single−stage thermostat, furnace will operate at three, staged rates (40/70/100%) with a time delay between each stage (values in grey−shaded
columns).
With two−stage thermostat there are two modes available.
Traditional two−stage mode − W1 demand results in 70% firing rate. W2 results in 100% firing rate. No delay between stages. (values shown in 70%
and 100% grey−shaded columns only).
Variable Rate Capacity Mode − furnace automatically adjusts firing rate based on first− and second−stage cycle times. (all columns)
Cool Mode
(Cooling Blower Performance table)
:
First stage COOL (two−stage air conditioning units only) is approximately 70
%
of the same second stage COOL speed position.
Continuous Fan speeds are approximately
28%, 38%, 70% and 100% (DIP switch selectable) of the same second−stage COOL speed position
minimum 250 cfm.
G71MPP−36B−070 BLOWER MOTOR WATTS − COOLING
Blower Speed
Options
Motor Watts @ Various External Static Pressures − in. wg.
First Stage
Second Stage
0
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
Increase (+10%) Cool CFM
Low
55
70
90
110
130
145
160
175
190
135
155
175
200
220
245
270
295
320
Medium−Low
75
90
110
130
150
170
190
205
220
185
215
250
285
315
345
370
395
420
Medium−High
85
100
120
145
165
185
205
225
250
235
265
300
335
370
400
425
455
480
High
105
125
150
170
190
210
235
255
280
315
340
370
395
440
480
510
540
570
Default Cool CFM
Low
45
60
80
95
115
130
145
160
175
100
120
140
165
190
215
235
255
275
Medium−Low
60
75
95
110
130
145
165
180
200
140
165
190
220
245
265
290
315
340
Medium−High
65
85
105
125
140
155
175
195
215
175
200
230
260
285
310
340
365
390
High
85
100
120
140
160
180
200
220
240
230
260
295
325
360
390
410
435
455
Decrease (–10%) Cool CFM
Low
40
55
70
85
100
120
130
145
160
75
90
110
125
150
175
190
210
225
Medium−Low
45
60
80
95
115
135
145
160
175
95
120
150
175
200
220
240
260
285
Medium−High
50
65
85
105
125
145
160
175
190
125
150
175
195
220
240
265
290
320
High
60
75
95
115
135
150
170
190
215
165
190
215
245
265
485
315
340
370