Page 10
TABLE 7
G71MPP−60C−110 BLOWER PERFORMANCE
(less filter)
−− Single Side Return Air
(Air volumes in bold require field fabricated transition to accommodate 20 x 25 x 1 in. cleanable air filter
in order to maintain proper air velocity across the filter.)
0 through 0.80 in. w.g. External Static Pressure Range
HEATING BLOWER PERFORMANCE
Heating Adjust CFM Selections
Heating Input Range and Blower Volume − CFM
40%
50%
60%
70%
80%
90%
100%
Increase (+15%) Heat CFM
870
1030
1185
1345
1490
1630
1775
Increase (+7.5%) Heat CFM
815
955
1095
1240
1380
1525
1670
Default Heat CFM
765
900
1035
1170
1305
1435
1570
Decrease (−7.5% ) Heat CFM
715
840
965
1090
1210
1330
1450
Decrease (−15% ) Heat CFM
650
765
880
995
1110
1225
1335
COOLING BLOWER PERFORMANCE
Cooling Adjust CFM
Selections
Blower Speed Selections
First Stage Cool Speed − cfm
Second Stage Cool Speed − cfm
Low
Medium−
Low
Medium
High
High
(Default)
Low
Medium−
Low
Medium
High
High
(Default)
Increase (+10%) Cool CFM
935
1025
1155
1285
1585
1700
1905
2135
Default Cool CFM
840
915
1050
1175
1435
1535
1740
1930
Decrease (–10%) Cool CFM
750
800
925
1050
1280
1385
1570
1755
The effect of static pressure is included in air volumes shown.
Lennox Harmony III
t
Zone Control Applications − Minimum blower speed is 450 cfm.
The following control board configurations are available. See Installation Instructions for details and DIP switch settings.
Heat Mode
(Heating Blower Performance Table):
With a single−stage thermostat, furnace will operate at three, staged rates (40/70/100%) with a time delay between each stage (values in grey−shaded
columns).
With two−stage thermostat there are two modes available.
Traditional two−stage mode − W1 demand results in 70% firing rate. W2 results in 100% firing rate. No delay between stages. (values shown in 70%
and 100% grey−shaded columns only).
Variable Rate Capacity Mode − furnace automatically adjusts firing rate based on first− and second−stage cycle times. (all columns)
Cool Mode
(Cooling Blower Performance table)
:
First stage COOL (two−stage air conditioning units only) is approximately 70
%
of the same second stage COOL speed position.
Continuous Fan speeds are approximately
28%, 38%, 70% and 100% (DIP switch selectable) of the same second−stage COOL speed position
minimum 450 cfm.
G71MPP−60C−110 BLOWER MOTOR WATTS − COOLING
Blower Speed
Options
Motor Watts @ Various External Static Pressures − in. wg.
First Stage
Second Stage
0
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
0
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0.80
Increase (+10%) Cool CFM
Low
70
90
110
130
150
165
185
210
230
255
295
345
390
430
470
510
545
585
Medium−Low
85
105
125
150
170
190
215
235
255
340
375
415
455
490
525
570
615
660
Medium−High
115
135
160
185
210
230
255
285
310
455
500
555
610
655
695
750
800
850
High
155
175
195
220
250
285
310
335
360
650
710
770
835
880
920
960
995
1035
Default Cool CFM
Low
60
75
90
110
125
145
165
185
205
195
230
270
305
345
380
415
455
490
Medium−Low
70
85
105
125
140
160
180
200
220
225
265
315
360
400
440
475
515
555
Medium−High
95
110
130
150
175
200
225
245
265
365
400
445
485
525
565
610
650
690
High
115
135
165
190
215
235
260
285
310
495
535
580
625
675
725
770
815
860
Decrease (–10%) Cool CFM
Low
45
60
80
100
110
125
140
155
170
155
180
205
235
270
305
340
370
400
Medium−Low
50
65
85
100
120
135
155
175
195
170
200
240
275
315
355
390
420
455
Medium−High
75
90
105
120
140
160
185
210
235
250
290
330
375
410
445
485
525
570
High
95
110
135
155
175
200
225
250
270
365
405
450
490
535
575
615
655
690