TWO−STAGE INTEGRATED CONTROL BOARD
FIGURE 4
THERMOSTAT CONNECTIONS (TB1)
DIP
SWITCHES
1 − 4
LEDs
FACTORY−
INSTALLED
JUMPER
DIP SWITCH(ES)
FUNCTION
1 and 2
Blower Off Delay (Heating Mode)
3
Second Stage ON Delay (Single−stage t’stat)
4
Blower Off Delay (Cooling Mode)
TABLE 3
Integrated Control Board Terminals
120VAC Neutral
LINE
Line
XFMR
Transformer
EAC
Electronic Air Cleaner
CIRC
Indoor Blower
HUM
Humidifier
120VAC Line
HUM
Humidifier
XMFR
Transformer
LINE
Line
PARK
For Unused Leads
COOL
Cooling Speed
EAC
Electronic Air Cleaner
HI HEAT
HIigh Heat Speed
LO HEAT
Low Heat, Low Cool and Continuous Fan
Speed
TABLE 4
Integrated Control Board 5 Pin Terminal
PIN #
Function
1
Ignitor
2
Combustion Air Inducer High Speed
3
Combustion Air Inducer Low Speed
4
Combustion Air Inducer Neutral
5
Ignitor Neutral
TABLE 5
Integrated Control Board 12Pin Terminal
PIN #
Function
1
Gas Valve 2nd Stage (High Fire)
2
Second Stage Prove Switch
3
Not Used
4
Ground
5
24V Hot
6
Primary Limit In
7
Gas Valve 1st stage (Low Fire)
8
Gas Valve Common
9
24V Neutral
10
Ground
11
Primary Limit Out
12
1st Stage Prove Switch