Page 10
ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ
ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ
ÉÉÉÉÉÉÉÉÉÉÉÉÉ
ÉÉ
ÉÉ
DEMAND
CAB
GAS VALVE
15
ON
OFF
ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ
ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ
ÉÉ
ÉÉ
38
ÉÉÉÉÉÉÉ
ÉÉÉÉÉÉÉ
IGNITOR
34
1
Pre −Purge
Ignitor Warmup
Trial for
Ignition
Post
Purge
5 SEC
80
*Blower on time will be 45 seconds after gas valve is energized. Blower off time will depend on OFF TIME" Setting.
INDOOR BLOWER
ÉÉÉÉÉÉÉÉÉÉ
ÉÉÉÉÉÉÉÉÉÉ
FIGURE 11
Blower On"
Delay
SureLight Control Ignition Sequence
Board 56L83, 24L85, 63K89
35
ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ
ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ
ÉÉÉÉÉÉÉÉÉÉÉÉÉ
ÉÉ
ÉÉ
DEMAND
CAB
GAS VALVE
15
ON
OFF
ÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉÉ
ÉÉ
ÉÉ
38
ÉÉÉÉÉÉÉÉÉÉ
ÉÉÉÉÉÉÉÉÉÉ
IGNITOR
34
1
Pre −Purge
Ignitor Warmup
Trial for
Ignition
Post
Purge
5 SEC
80
*Blower on time will be 45 seconds after gas valve is energized. Blower off time will depend on OFF TIME" Setting.
INDOOR BLOWER
ÉÉÉÉÉÉÉÉÉ
ÉÉÉÉÉÉÉÉÉ
FIGURE 12
Blower On"
Delay
SureLight Control Ignition Sequence Board 97L48
7. Two−Stage Control (A86)
All G32−1 through −4 units are equipped with a two−stage
control board. Two different boards have been used. Board
43K9001 and board 25M3301 (figure 13) are identical, ex
cept the 9 pin connector on 43K9001 is replaced by two re
lays with quick connect terminals on 25M3301. The two−
stage board acts as a go between from the indoor thermo
stat to the SureLight ignition board. The board can be uti
lized in three modes: with a SINGLE−STAGE thermostat, a
TWO−STAGE thermostat or with a second−stage (high fire)
delay called W2 TIMED. The two−stage board is equipped
with a jumper (see figure 13) which changes operating
modes and a jumper which adjusts second−stage heat
delay during W2 TIMED mode.
While in the single−stage thermostat mode (one−stage
jumper setting), the unit will always operate on second−
stage heat. The combustion air blower (B6) will operate on
high speed and indoor blower (B3) will operate on heating
speed. While in the two−stage thermostat mode the unit will
operate on first−stage heat (low fire). The combustion air
blower (B6) and indoor blower will operate on low speed.
The unit will switch to second−stage heat (high fire) on call
from the indoor thermostat W2. While in the W2 TIMED
mode (factory setting 8 minutes) the unit will fire on first−
stage heat (low fire) with the combustion air blower (B6)
and indoor blower (B3) operating on low speed. After a set
time delay the unit switches to second−stage heat (high
fire). The combustion air blower and indoor blower also
switch to second−stage heat mode.
TWO−STAGE CONTROL BOARD 25M3301
FIGURE 13
MODE OF
OPERATION
JUMPER
W2 TIMED
ON DELAY
JUMPER