SPECIFICATIONS (units equipped with conventional multispeed blower motor)
Model No.
G21Q340
G21Q360
G21Q460
Input Btuh
40,000
60,000
60,000
Output Btuh
38,000
55,000
55,000
*A.F.U.E.
96.2%
94.1%
94.1%
California Seasonal Efficiency
90.7%
89.9%
88.8%
Temperature rise range (
°
F)
35 65
40 70
35 65
High static certified by A.G.A. (in wg.)
.50
.50
.50
Gas Piping Size
Natural
1/2
1/2
1/2
I.P.S. (in.)
**LPG
1/2
1/2
1/2
Vent/Intake air pipe size connection (in.)
2
2
2
Condensate drain connection (in.) SDR11
1/2
1/2
1/2
Blower wheel nominal diameter x width (in.)
10 x 8
10 x 8
11 x 9
Blower motor hp
1/3
1/3
1/2
Number and size of filters (in.)
(1) 16 x 25 x 1
(1) 16 x 25 x 1
(1) 16 x 25 x 1
Tons of cooling that can be added
11/2 3
11/2 3
21/2 4
Electrical characteristics
120 volts 60 hertz 1 phase (less than 12 amps) All models
**LPG kit (optional)
LB65810A
LB65810B
LB65810B
External Filter Mounting
Part No.
LB81871CA
LB81871CA
LB81871CA
Kit (optional)
•
Filter size (in.)
(1) 16 x 25 x 1
(1) 16 x 25 x 1
(1) 16 x 25 x 1
•
Filter is not furnished with kit. Filter kit utilizes existing filter supplied with G21 unit.
*Annual Fuel Utilization Efficiency based on D.O.E. test procedures and according to F.T.C. labeling regulations.
Isolated combustion system rating for nonweatherized furnaces.
**LPG kit must be ordered extra for field changeover.
SPECIFICATIONS (units equipped with conventional multispeed blower motor)
Model No.
G21Q380
G21Q480
G21Q580
G21Q3100
G21Q4/5100
Input Btuh
80,000
80,000
80,000
100,000
100,000
Output Btuh
73,000
73,000
74,000
93,000
95,000
*A.F.U.E.
93.9%
93.9%
93.2%
94.9%
94.5%
California Seasonal Efficiency
90.1%
88.9%
88.3%
90.8%
89.6%
Temperature rise range (
°
F)
45 75
40 70
35 65
55 85
40 70
High static certified by A.G.A. (in wg.)
.50
.50
.50
.50
.50
Gas Piping Size
Natural
1/2
1/2
1/2
1/2
1/2
I.P.S. (in.)
**LPG
1/2
1/2
1/2
1/2
1/2
Vent/Intake air pipe size connection (in.)
2
2
2
2
2
Condensate drain connection (in.) SDR11
1/2
1/2
1/2
1/2
1/2
Blower wheel nominal diameter x width (in.)
10 x 8
11 x 9
12 x 12
10 x 8
12 x 12
Blower motor hp
1/3
1/2
3/4
1/2
3/4
Number and size of filters (in.)
(1) 16 x 25 x 1
(1) 16 x 25 x 1
(1) 20 x 25 x 1
(1) 20 x 25 x 1
(1) 20 x 25 x 1
Tons of cooling that can be added
2 3
21/2 4
4 or 5
2 3
31/2 5
Electrical characteristics
120 volts 60 hertz 1 phase (less than 12 amps) All models
**LPG kit (optional)
LB65810B
LB65810B
LB65810B
LB65810C
LB65810C
External Filter Mounting
Part No.
LB81871CA
LB81871CA
LB81871CB
LB81871CB
LB81871CB
Kit (optional)
•
Filter size (in.)
(1) 16 x 25 x 1
(1) 16 x 25 x 1
(1) 20 x 25 x 1
(1) 20 x 25 x 1
(1) 20 x 25 x 1
•
Filter is not furnished with kit. Filter kit utilizes existing filter supplied with G21 unit.
*Annual Fuel Utilization Efficiency based on D.O.E. test procedures and according to F.T.C. labeling regulations.
Isolated combustion system rating for nonweatherized furnaces.
**LPG kit must be ordered extra for field changeover.
Содержание G21Q3-80
Страница 73: ...G21V 1 2 3 4 5 6 7 8 10 9 11 12 14 15 16 17 20 21 22 23 24 25 26 27 28 19 Page 73 29 30 31 32 13 ...
Страница 75: ...GSR21V Page 75 1 2 3 4 5 6 8 10 9 11 12 14 15 16 17 20 19 21 22 23 24 25 26 27 28 24 29 30 31 32 7 13 ...
Страница 87: ...G21V with GC3 Ignition Control 1 2 3 4 5 6 7 8 10 9 11 12 13 14 15 16 17 20 21 22 23 24 25 26 27 28 19 Page 87 ...