G21V/GSR21V OPERATION SEQUENCE AND JUMPERS SUMMARY WITH VSP1 (COOLING)
TABLE 22 (contd.)
Harmony and Two
Speed Compressor
No Jumpers
Harmony and Single
Speed Compressor
No Jumpers
Blower operates on
PWM signal generated
by Harmony. Harmony
overrides blower speed
taps. Blower speed varies
according to zone de
mand.
Blower operates on
PWM signal generated
by Harmony. Harmony
overrides blower speed
taps. Blower speed varies
according to zone de
mand.
(continued from previous page)
W1
W2
R
G
Y1
Y2
DS
C
HB
CCB1 with TwoSpeed
Compressor, no Har
mony
Blower speed is controlled by
the DC signal from CCB1.
Blower operates on low speed
heat/cool tap during dehumidi
fication. Otherwise, blower op
erates on high speed cool tap
during high speed compressor
operation and low speed heat/
cool tap during low speed
compressor operation
No Jumpers
A20 HUMIDITY CONTROL
S1
THERMOSTAT
TO
OUTDOOR
UNIT
W1
W2
R
G
Y1
Y2
DS
C
HB
W1
W2
R
G
Y1
Y2
DS
C
HB
TO
OUTDOOR
UNIT
TO
OUTDOOR
UNIT
TB1 TERMINAL STRIP
TB1 TERMINAL STRIP
TB1 TERMINAL STRIP
ZONE
CONTROLLER
A1
HARMONY
ZONE
CONTROLLER
A1
HARMONY
FOR HEATING JUMPERS
SEE TABLE 21