XP16 − 2 to 5 Ton Heat Pump
ARI RATINGS
1
ARI Standard 210/240 Ratings
Capacity − Btuh
Efficiency
Total Watts
COP
I d
U it M d l N
Expansion
Cooling
High
Temp
Low
Temp
HSPF
Cool
High Low High Low
Indoor Unit Model No.
Expansion
Device
Cooling Temp.
Heating
Temp.
Heating SEER EER
IV
V
Cool
High
Heat
Low
Heat
High
Heat
Low
Heat
XP16−036
3 TON
Up−Flow Indoor Coils + Furnaces
Up−Flow Coils + Furnaces
35,600 33,600 20,400 15.20 11.20 8.20 7.00 3125 2915 2490 3.38 2.40 CX34−38A−6F
4
G60UHV−36A−070
Factory TXV
35,600 33,600 20,400 15.20 11.20 8.20 7.00 3145 2930 2505 3.36 2.38 CX34−38B−6F
4
G61MPV−36B−045
Factory TXV
35,600 33,400 20,200 15.20 11.50 8.20 7.00 3100 2910 2475 3.36 2.38 CX34−38B−6F
4
G61MPV−36B−070
Factory TXV
35,600 33,400 20,200 15.20 11.50 8.20 7.00 3100 2910 2475 3.36 2.38 CX34−38B−6F
4
G71MPP−36B−070
Factory TXV
35,800 33,200 20,000 15.70 11.70 8.20 7.20 3040 2830 2405 3.44 2.44 CX34−38B−6F
4
G60UHV−36B−090
Factory TXV
36,200 32,200 19,500 16.00 11.70 7.70 6.70 3035 3075 2580 3.06 2.22 C33−44C
4
G61MPV−36C−090
2
49L24
36,200 32,200 19,500 16.00 11.70 7.70 6.70 3035 3075 2580 3.06 2.22 C33−44C
4
G71MPP−36C−090
2
49L24
36,400 32,000 19,400 16.00 12.00 7.70 6.70 3000 3080 2560 3.04 2.22 CX34−43C−6F
4
G61MPV−36C−090
2
49L24
36,400 32,000 19,400 16.00 12.00 7.70 6.70 3000 3080 2560 3.04 2.22 CX34−43C−6F
4
G71MPP−36C−090
2
49L24
36,400 32,200 19,500 16.00 11.70 7.70 6.70 3040 3095 2585 3.04 2.20 CX34−43B−6F
4
G60UHV−36B−090
2
49L24
Down−Flow Indoor Coils
Down−Flow Coils
34,800 33,400 20,400 13.70 10.90 7.70 6.70 3190 3065 2610 3.20 2.28
3
CR33−48B/C−F
2
49L24
35,800 34,000 20,600 14.20 11.20 8.20 7.00 3195 2950 2555 3.38 2.36
3
CR33−50/60C−F
2
49L24
Down−Flow Indoor Coils + Furnaces
Down−Flow Coils + Furnaces
35,200 33,200 20,200 15.20 11.20 8.00 7.00 3100 2980 2520 3.26 2.34 CR33−48B−F
4
G61MPV−36B−070
2
49L24
35,200 33,200 20,200 15.20 11.20 8.00 7.00 3100 2980 2520 3.26 2.34 CR33−48B−F
4
G71MPP−36B−070
2
49L24
35,200 33,400 20,200 15.20 11.20 8.00 7.00 3140 2995 2550 3.26 2.32 CR33−48B−F
4
G61MPV−36B−045
2
49L24
35,400 32,800 19,800 15.70 11.70 8.00 7.00 3000 2885 2425 3.34 2.40 CR33−48C−F
4
G61MPV−36C−090
2
49L24
35,400 32,800 19,800 15.70 11.70 8.00 7.00 3000 2885 2425 3.34 2.40 CR33−48C−F
4
G71MPP−36C−090
2
49L24
35,400 32,800 19,900 15.50 11.50 8.00 7.00 3015 2890 2435 3.32 2.40 CR33−48B−F
4
G60DFV−36B−090
2
49L24
36,400 33,200 20,000 16.00 12.00 8.50 7.20 3005 2765 2370 3.52 2.48 CR33−50/60C−F
4
G61MPV−36C−090
2
49L24
36,400 33,200 20,000 16.00 12.00 8.50 7.20 3005 2765 2370 3.52 2.48 CR33−50/60C−F
4
G71MPP−36C−090
2
49L24
Horizontal Indoor Coils
Horizontal Coils
34,800 33,600 20,400 13.70 10.95 7.70 6.70 3185 3045 2595 3.24 2.30
3
CH23−51
2
49L24
35,200 33,800 20,600 14.00 11.00 8.00 7.00 3190 2980 2555 3.32 2.36
3
CH23−65
2
49L24
Horizontal Indoor Coils + Furnaces
Horizontal Coils + Furnaces
35,800 32,200 19,500 15.70 11.70 7.70 6.70 3035 3105 2590 3.04 2.20 CH33−42B−2F
4
G60UHV−36B−090
2
49L24
36,200 32,000 19,400 16.00 12.00 7.70 6.70 3000 3085 2565 3.04 2.22 CH33−48C−2F
4
G61MPV−36C−090
2
49L24
36,200 32,000 19,400 16.00 12.00 7.70 6.70 3000 3085 2565 3.04 2.22 CH33−48C−2F
4
G71MPP−36C−090
2
49L24
36,200 32,200 19,500 16.00 11.70 7.70 6.70 3040 3075 2585 3.06 2.20 CH33−44/48B−2F
4
G60UHV−36B−090
2
49L24
XP16−048
4 TON
Air Handlers
Air Handlers
47,000
44,500
26,400 16.00 11.70 8.20 7.00 3995 3895 3315 3.34 2.34
4
CBX32MV−048 (Multi−Position)
Factory TXV
47,000 45,000 26,800 15.70 11.70 8.00 6.70 3960 3990 3375 3.30 2.32
4
CBX27UH−060 (Up−Flow/Horizontal)
Factory TXV
47,000
44,500
26,600 14.70 11.50 8.00 7.00 4055 3970 3380 3.28 2.30
3
CBX32M−048 (Multi−Position)
Factory TXV
47,500 45,000 27,000 15.70 12.00 8.00 7.00 3960 3910 3320 3.38 2.38
4
CBX27UH−048 (Up−Flow/Horizontal)
Factory TXV
47,500
43,000
25,800 15.70 12.00 7.70 6.70 3945 4070 3400 3.10 2.22
4
CBX32MV−068 (Multi−Position)
Factory TXV
47,500
44,000
26,000 16.00 12.00 8.20 7.00 3935 3865 3280 3.34 2.32
4,5
CBX32MV−060 (Multi−Position)
Factory TXV
47,500
45,000
26,800 14.50 11.20 8.00 6.70 4240 4045 3480 3.26 2.26
3
CBX32M−060 (Multi−Position)
Factory TXV
NOTE − When used with gas furnaces, a dual−fuel control (i.e. FM21) or a control system with dual−fuel capabilities (i.e. Harmony III, LZP−2 or LZP−4) must be used (ordered extra).
1
Certified in accordance with USE certification program which is based on ARI Standard 210/240 with 25 ft. of connecting refrigerant lines;
Cooling Ratings −
95
_
F outdoor air temperature and 80
_
F db/67
_
F wb entering indoor coil air.
High Temperature Heating Ratings −
47
_
F db/43
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
Low Temperature Heating Ratings −
17
_
F db/15
_
F wb outdoor air temperature and 70
_
F db entering indoor coil air.
2
Factory installed expansion valve or RFC on indoor unit MUST be replaced with valve specified (if equipped).
3
Blower must be capable of time−off blower delay. Indoor Blower Off Delay Relay (
58M81
) is recommend for field installation.
4
Blower control must be set for a time−off blower delay.
5
Most popular air handler combination.