SPECIFICATIONS
General
D t
Model No. XP13−018 XP13−024 XP13−030 XP13−036 XP13−037 XP13−042 XP13−048 XP13−060
Data
Nominal Tonnage
1.5
2
2.5
3
3+
3.5
4
5
Connections
(
t)
Liquid line (o.d.) − in.
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/8
(sweat)
Vapor line (o.d.)
3/4
3/4
3/4
3/4
3/4
7/8
7/8
1−1/8
Refrigerant
1
R−410A charge furnished
8 lbs.
15 oz.
7 lbs.
7 oz.
7 lbs.
10 oz.
10 lbs.
2 oz.
10 lbs.
3 oz.
11 lbs.
10 oz.
11 lbs.
10 oz.
15 lbs.
0 oz.
Outdoor
C il
Net face area
ft
Outer coil
13.22
13.22
13.22
15.11
18.67
18.67
18.67
24.50
Coil
sq. ft.
Inner coil
12.65
12.65
12.65
14.46
18.00
18.00
18.00
23.64
Tube diameter − in.
5/16
5/16
5/16
5/16
5/16
5/16
5/16
5/16
No. of Rows
2
2
2
2
2
2
2
2
Fins per inch
22
22
22
22
22
22
22
22
Outdoor
F
Diameter − in.
18
18
18
18
22
22
22
22
Fan
No. of blades
3
3
3
3
4
4
4
4
Motor hp
1/10
1/10
1/10
1/10
1/6
1/6
1/4
1/4
Cfm
2215
2215
2270
2330
3150
3150
3730
3980
Rpm
1040
1040
1050
1060
844
844
824
836
Watts
145
145
165
170
215
215
320
305
Shipping Data −
lbs. 1 pkg.
189
188
192
208
235
260
267
305
ELECTRICAL DATA
Line voltage data − 60hz − 1 phase 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V
3
Maximum overcurrent protection (amps)
20
30
30
35
35
40
50
60
2
Minimum circuit ampacity
11.9
17.5
18.4
21.6
21.9
23.2
28.9
34.6
Compressor
Rated load amps
8.97
13.46
14.1
16.67
16.67
17.69
21.79
26.28
p
Locked rotor amps
48
58
73
79
79
107
117
134
Power factor
0.98
0.98
0.98
0.99
0.99
0.99
0.99
0.99
Outdoor Fan
M t
Full load amps
0.7
0.7
0.7
0.7
1.1
1.1
1.7
1.7
Motor
Locked Rotor Amps
1.4
1.4
1.4
1.4
2.1
2.1
2.1
3.1
OPTIONAL ACCESSORIES − must be ordered extra
Compressor Hard Start Kit
10J42
p
88M91
Compressor Crankcase Heater
93M04
Factory
Compressor Low Ambient
Cut−Off
45F08
Compressor Sound Cover
69J03
Freezestat
3/8 in. tubing
93G35
5/8 in. tubing
50A93
Low Ambient Kit
54M89
Low Pressure Switch Bypass
Thermostat
13W07
Mild Weather Kit
33M07
Monitor Kit − Service Light
76F53
Outdoor
Th
t t Kit
Thermostat
56A87
Thermostat Kit
Mounting Box
31461
Refrigerant
Line Sets
L15−41−20
L15−41−30
L15−41−40
L15−41−50
L15−65−30
L15−65−40
L15−65−50
Field Fabricate
Time Delay Relay
58M81
NOTE − Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Refrigerant charge sufficient for 15 ft. length of refrigerant lines.
2
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
3
HACR type breaker or fuse.