CONGRATULATIONS!

In selecting this LENNOX Direct-Vent Gas Appliance you have chosen the finest and most
dependable fireplace to be found anywhere.  A beautiful, prestigious, alternative to a
wood burning fireplace.  Welcome to a Family of tens of thousands of satisfied LENNOX
Fireplace Owners.

Please read and carefully follow all of the instructions found in this manual.  Please pay
special attention to the safety instructions provided in this manual.  The Homeowner's
Care and Operation Instructions included here will assure that you have many years of
dependable and enjoyable service from your LENNOX product.

GENERAL INFORMATION

Note: 

Installation and repair should be performed

by a qualified service person. The appliance
should be inspected annually by a qualified pro-
fessional service technician. More frequent in-
spections and cleanings may be required due to
excessive lint from carpeting, bedding material,
etc. It is imperative that the control compart-
ment, burners and circulating air passage ways
of the appliance be kept clean.

S'assurer que le brùleur et le compartiment
des commandes sont propres.  Voir les in-
structions d'installation et d'utilisation qui
accompagnent l'appareil.

Provide adequate clearances around air open-
ings and adequate accessibility clearance for
service and proper operation. Never obstruct
the front openings of the appliance.

Due to high temperatures the appliance should
be located out of traffic and away from furni-
ture and draperies.  Locate furniture and win-
dow coverings accordingly.

Direct-Vent appliances operate with the com-
bustion chamber completely isolated from the
inside atmosphere.  All air for combustion is
brought in from the outside and  exhaust gases
are vented through the same direct vent, vent
system.

The millivolt appliances are designed to oper-
ate on either natural or propane gas. A millivolt
gas control valve with piezo ignition system
provides safe, efficient operation.  External
electrical power is required to operate the
optional electrically powered components if
installed.  Electrical power must be wired dur-
ing appliance installation.

The electronic appliances are designed to op-
erate on either natural or propane gas. An
electronic intermittent pilot system provides
safe, efficient operation. External electrical
power is required to operate these units.

These appliances comply with National Safety
Standards and are tested and listed by Omni-
Test Laboratories (Report No. 116-F-05-5) to
ANSI Z21.88-2002 (in Canada, CSA-2.33-
2002), and CAN/CGA-2.17-M91 in both USA
and Canada, as vented gas fireplace heaters.

The Installation must conform to local codes
or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA
54, or the Natural Gas and Propane Installa-
tion Code, CSA B149.1.  The appliance, when
installed, must be electrically grounded in
accordance with local codes or, in the ab-
sence of local codes, with the 

National Elec-

trical Code, ANSI/NFPA 70, or the Canadian
Electrical Code, CSA C22.1.

DO NOT ATTEMPT TO ALTER OR MODIFY
THE CONSTRUCTION OF THE APPLIANCE OR
ITS COMPONENTS. ANY MODIFICATION OR
ALTERATION MAY VOID THE WARRANTY,
CERTIFICATION AND LISTINGS OF THIS UNIT.

TABLE OF CONTENTS

Introduction ............................................ page

2

General Information ................................ page

2

Operation/Care of Your Appliance .......... page

3

Variable Flame Adjustment ..................... page

4

Glass Cleaning ........................................ page

5

Maintenance ........................................... page

5

Front Glass Enclosure Panel,

  Removal and Installation ...................... page

5

Maintenance Schedule ............................ page

6

Burner Adjustments ................................ page

7

Flame Appearance and Sooting .............. page

7

Adjustment ............................................. page

7

Log Placement ........................................ page

8

Decorative Volcanic Stone Placement .... page

9

Millivolt Appliance Checkout ................... page

9

Electronic Appliance Checkout ............... page

9

Accessory Components .......................... page

9

Wiring Diagrams .................................... page

14

Warranty ................................................. page

14

Replacement Parts ................................. page

14

Product Reference Information .............. page

14

Lighting Instructions – Millivolt .............. page

16

Lighting Instructions – Electronic ........... page

18

Troubleshooting Guide – Millivolt ............ page

20

Troubleshooting Guide – Electronic ......... page

21

Replacement Parts List ........................... page

22

WARNING: THESE FIREPLACES ARE
VENTED HEATERS.  DO NOT BURN
WOOD OR OTHER MATERIAL IN THESE
APPLIANCES.

WARNING: IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE.  REFER TO
THIS MANUAL.  FOR ASSISTANCE OR
ADDITIONAL INFORMATION CONSULT
A QUALIFIED INSTALLER, SERVICE
AGENCY OR THE GAS SUPPLIER.

WARNING: ELECTRONIC MODELS OF
THESE APPLIANCES ARE EQUIPPED
WITH A THREE-PRONG (GROUNDING)
PLUG UTILIZED IN CONNECTING THE
ELECTRONIC COMPONENTS TO THE
JUNCTION BOX IN THE LOWER COM-
PARTMENT.  THIS GROUNDING PLUG
PROVIDES PROTECTION AGAINST
SHOCK HAZARD AND SHOULD BE
PLUGGED DIRECTLY INTO THE PROP-
ERLY GROUNDED THREE-PRONG RE-
CEPTACLE.  DO NOT CUT OR REMOVE
THE GROUNDING PRONG FROM THE
PLUG.

INTRODUCTION

The Fireplace models covered in this manual
are Direct-Vent sealed combustion gas fire-
place heaters designed for residential applica-
tion.

Содержание Elite series

Страница 1: ...cutéparunqualifié installeur agencedeserviceoulefournisseurdegaz DIRECT VENT ELITE SERIES RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE OTL Report No 116 F 05 5 s l e d o M t l o v i l l i M s l e d o M c i n o r t c e l E M N C 0 3 5 3 V D E E N C 0 3 5 3 V D E M N C 5 3 0 4 V D E E N C 5 3 0 4 V D E M N C 0 4 5 4 V D E E N C 0 4 5 4 V D E M P C 0 3 5 3 V D E B E N C 0 3 5 3 V D E M P C 5 3 0 4 ...

Страница 2: ...e these units These appliances comply with National Safety Standards and are tested and listed by Omni Test Laboratories Report No 116 F 05 5 to ANSI Z21 88 2002 in Canada CSA 2 33 2002 and CAN CGA 2 17 M91 in both USA and Canada as vented gas fireplace heaters The Installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the N...

Страница 3: ... V D E 0 0 0 3 3 o N l e d o M e z i s e c i f i r O n o i t a v e l E t e e F s r e t e m t a N p o r P 0 3 5 3 V D E 0 4 3 5 0 0 5 4 0 2 7 3 1 0 5 3 0 4 V D E 6 3 2 5 0 4 5 4 V D E 3 3 1 5 WARNING FAILURE TO COMPLY WITH THE INSTALLATION AND OPER ATING INSTRUCTIONS PROVIDED IN THIS DOCUMENT WILL RESULT IN AN IMPROPERLY INSTALLED AND OP ERATING APPLIANCE VOIDING ITS WARRANTY ANY CHANGE TO THIS APP...

Страница 4: ...ctronic Appliances To light electronic appliances refer to the detailed lighting instructions found in both English and French on pages 13 and 14 of these instructions respectively Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve Electronic appliances are fitted with an ON OFF Rocker Switch for appliance ON O...

Страница 5: ...O NOT USE ABRASIVE CLEANERS NEVER CLEAN THE GLASS WHEN IT IS HOT Front Glass Enclosure Panel Removal and Installation These are direct vent appliances They are de signed to operate only when the front glass enclosure panel is installed Generally the front glass enclosure panel should not be removed except to gain access to the components within the firebox and the appliance may only be oper ated w...

Страница 6: ...res 6 EDV3530 7 EDV4035 or 8 EDV4540 on page 7 and verify the flame pattern and height displayed by the appliance conforms to the picture Flames must not impinge on the logs RefertoFigure9 SIT orFigure10 Honeywell on page 8 Remove any surface build up on pilotandburnerassembly Wipethepilotnozzles ignitor flame rod and hood Ensure the pilot flame engulfs the flame sensor as shown Inspect the vent s...

Страница 7: ... opening respectively Position the air shutter to the factory setting as shown in Figure 5 on page 7 Allow the burner to operate for at least 15 minutes Observe the flame continuously If it appears weak or sooty as previously de scribed adjust the air shutter by pushing or pulling on the adjustment rod until the flame appearance is as desired Theadjustmentrodandassociatedadjustableair shutter is p...

Страница 8: ...n a p o r P m m s e h c n i 0 3 5 3 V D E 8 1 2 3 8 3 5 9 5 3 0 4 V D E 5 9 8 3 0 4 5 4 V D E 5 9 8 3 Air Shutter Opening Burner Venturi Tube Air Shutter Door Orifice Increase Air Shutter Opening Decrease Air Shutter Opening Air Shutter Adjusting Arm WARNING LOGS GET VERY HOT AND WILL REMAIN HOT UP TO ONE HOUR AFTER GAS SUPPLY IS TURNED OFF HANDLE ONLY WHEN LOGS ARE COOL TURN OFF ALL ELECTRICITY T...

Страница 9: ... hardware re quired to install the unit The remote receiver can be wall or hearth mounted Deluxe Remote Control System The Model RCL T Deluxe Remote Control System has all of the features of the standard system along with an added easy to read LCD screen which presents access to many en hancements including battery power level in dicator timer mode of operation thermostatic display including room ...

Страница 10: ...K l e n a P e c a F n a e l C o N l e d o M o N g o l a t a C o N l e d o M 0 3 5 3 V D E 6 3 L 8 8 2 C 5 3 D A R 5 3 0 4 V D E 7 3 L 8 8 2 C 0 4 D A R 0 4 5 4 V D E 8 3 L 8 8 2 C 5 4 D A R s t i K r e v u o L d e l b m e s s A o N l e d o M o N g o l a t a C o N l e d o M d e h s i l o P s s a r B d e h s u r B s s e l n i a t S 0 3 5 3 V D E 8 2 L 8 8 2 B P 5 3 R V L 2 3 L 8 8 S B 5 3 R V L 5 3 ...

Страница 11: ... between the wall board and the fireplace providing the appliance a brass perimeter highlight s t i K m i r T h s i n i F o N l e d o M o N g o l a t a C o N l e d o M d e h s i l o P s s a r B 0 3 5 3 V D E 4 5 4 0 H 3 B P E 5 3 K T 5 3 0 4 V D E 2 2 K 6 9 3 B P 0 4 K T 0 4 5 4 V D E 3 2 K 6 9 3 B P 5 4 K T The brickaded panel liner kits include ceramic panels of the side walls the rear and the b...

Страница 12: ...wter H0941 APD45AB 45 Arch Pane Doors Antique Brass H0942 APD35EC 35 Elite Arch Pane Doors Charcoal H0943 APD35ETI 35 Elite Arch Pane Doors Textured Iron H0944 APD35ESP 35 Elite Arch Pane Doors Satin Pewter H0945 APD35EAB 35 Elite Arch Pane Doors Antique Brass EDV4035 EDV4540 EDV3530 SQUARE DESIGN KITS Cat No Model Description Model Series H0950 SD40C 40 Sq Doors Charcoal H0951 SD40TI 40 Sq Doors ...

Страница 13: ...3 CLGK40C 40 Crescents Lower Grille Kit Charcoal H3555 40 Crescents Lower Grille Kit Satin Pewter CLGK40SP H3557 CUGK45C 45 Crescents Upper Grille Kit Charcoal EDV4540 H3559 45 Crescents Upper Grille Kit Satin Pewter CUGK45SP H3561 CLGK45C 45 Crescents Lower Grille Kit Charcoal H3563 45 Crescents Lower Grille Kit Satin Pewter CLGK45SP Sunrise Grille Kits Cat No Model Description Model Series H3565...

Страница 14: ...TION Thermopile TH TP TH TP Millivolt Wiring Diagram If any of the original wire as supplied must be replaced it must be replaced with Type AWM 105 C 18 GA wire OR OPTIONAL WALL MOUNTED ON OFF SWITCH OR OPTIONAL THERMOSTAT OR OPTIONAL REMOTE CONTROL RECEIVER Factory Wired Field Wired Schematic Representation Only APPLIANCE MOUNTED ON OFF SWITCH Turn the appliance mounted ON OFF burner control swit...

Страница 15: ...15 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE NOTES ...

Страница 16: ...ontrol knob all the way and hold in Immediately light the pilot by triggering the spark ignitor pushing the button until pilot lights Continue to hold the control knob in for about 1 minutes after the pilot is lit Release knob and it will pop back up Pilot should remain lit If it goes out repeat steps 5 through 8 If knob does not pop up when released stop and immediately call your service technici...

Страница 17: ...allume gaz à étincelle en poussant le bouton jusqu à ce que la veilleuse s enflamme Continuez de tenir le bouton de réglage enfoncé pendant environ 90 secondes après l allumage de la veilleuse Relâchez le bouton et il sortira subitement La veilleuse devrait rester allumée Si elle s éteint répétez les étapes 5 à 8 inclusivement Si le bouton ne sort pas automatiquement après avoir été relâché arrête...

Страница 18: ...y part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS ELECTRONIC 1 For complete shut down turn remote wall switch to OFF 2 Open lower control compartment door 3 Turn the ON OFF switch to OFF Do not force 4 Close the main line shut off valve 5 Close lower control compartment door TO TURN OFF GAS TO APPLIANCE LIGHTING INSTRUCTIONS 1 STOP Read the safety in...

Страница 19: ...osition d arrêt OFF 3 Ouvrez la porte du compartiment de contrôle du bas 4 Assurez vousquelasoupaped arrêtdelacanalisationprincipale est ouverte 5 Tournezlamanettederéglagedugazàlapositiond arrêt OFF 6 Attendez cinq 5 minutes pour l evacuation du gaz Si vous décelez une odeur de gaz ARRÊTEZ Retournez au point B des consignes de sécurité au verso de cette plaque Si vous ne remarquez aucune odeur de...

Страница 20: ...a qualified service technician Clean and or adjust pilot flame for maximum flame impinge ment on thermocouple Figure 9 on page 8 Check burner orifice for stoppage and remove Checkthermopilewithmillivoltmeter Takereadingatthermo pile terminals of gas valve Should read 325 millivolts mini mum with optional wall switch OFF Replace faulty thermo pile if reading is below specified minimum Check wall sw...

Страница 21: ... NO Plug Control Harness Into Valve Wait For Internal Check Delay YES Igniter Warms Up And Glows Red With Pilot Burner Cable Connected Measure Voltage At Valve HSI Element Output 24V Nominal See Insert B NO Replace Igniter Flame Rod Assembly YES Replace Valve NO Turn On Gas Supply Pilot Burner Lights Check That Pilot Gas Is Flowing Wait To Assure Plot Gas Tubing Is Purged Recycle Call For Heat If ...

Страница 22: ...t a L 1 2 L 9 6 2 1 2 L 9 6 2 1 2 L 9 6 2 9 c i t e n g a M r o o D h c t a C 1 3 L 9 6 1 1 3 L 9 6 1 1 3 L 9 6 1 0 1 e t e l p m o C t e S g o L 2 0 M 5 5 1 3 0 M 5 5 1 3 0 M 5 5 1 1 1 y l b m e s s A r e n r u B 9 2 M 5 5 1 0 3 M 5 5 1 0 3 M 5 5 1 2 1 y l b m e s s A e t a r G 0 9 9 4 H 1 1 9 9 4 H 1 1 9 9 4 H 1 3 1 r e t t u h s r i A i r u t n e V 7 0 7 3 H 1 7 0 7 3 H 1 7 0 7 3 H 1 4 1 r e n ...

Страница 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS 4 8 14 7 41 40 31 30 43 33 32 34 42 36 35 16 13 2 5 6 2 3 17 18 19 11 9 1 12 21 10 15 20 EDV4035 EDV4540 EDV3530 ...

Страница 24: ...75 021M REV G 03 2007 Lennox Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 1110 West Taft Avenue Orange CA 92865 ...

Отзывы: