background image

MODELS

INSTALLATION INSTRUC

TIONS

Elite Linear View  

Direct-Vent Gas Fireplace

P/N 506011-02   Rev. NC   06/2012 

This manual is one of a set of two supporting this product.  

Refer to P/N 506013-02 for Care and Operation Instructions.
Ce manuel est disponible en francais, simplement  

en faire la demande. Numéro de la pièce 506223-37.

Please read and understand these instructions  

before starting installation.

AVERTISSEMENT : Assurez-vous de bien suivre les

instructions données dans cette notice pour réduire au

minimum le risque d’incindie ou d’explosion ou pour

éviter tout dommage matériel, toute blessure ou la mort.   

 

 

 

 

 

WARNING: If the information in these instructions

is not followed exactly, a fire or explosion may

result, causing property damage, personal injury,

or death.   

WARNING /AVERTISSEMENT/AVISO

•  HOT GLASS WILL CAUSE 

  BURNS. 

• DO NOT TOUCH GLASS 

  UNTIL COOLED.

• NEVER ALLOW CHILDREN 

  TO TOUCH GLASS.

 

•  UNE SURFACE VITRÉE CHAUDE 

  PEUT CAUSER DES BRÛLURES. 

• LAISSER REFROIDIR LA SURFACE 

  VITRÉE AVANT D'Y TOUCHER. 

• NE PERMETTEZ JAMAIS À UN ENFANT 

  DE TOUCHER LA SURFACE VITRÉE.

•  EL VIDRIO CALIENTE 

  CAUSARÁ QUEMADURAS. 

• USTED DEBE NUNCA 

  TOCAR EL VIDRIO CALIENTE. 

• LOS NIÑOS DEBEN NUNCA 

  TOCAR EL VIDRIO.

- Do not store or use gasoline or other flammable

  vapors and liquids in the vicinity of this or any other

  appliance. 

- WHAT TO DO IF YOU SMELL GAS:

  • Do not t

ry to light any appliance.

  • Do not touch any electrical switch; do not use any

    phone in your building.

  • Immediately call your gas supplier from a

    neighbor’

s phone. Follow the gas supplier

’s

    instructions.

  • If you cannot reach your gas supplier, call the fire

    department.
- Installation and service must be performed by a

  qualified installer, service agency or the gas supplier.

- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs

  ou liquides inflammables dans le voisinage de cet appareil

  ou de tout autre appareil. 

- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :

  • Ne pas tenter d’allumer d’appareil.

  • Ne touchez à aucan interrupteu

r. Ne pas vous servir des

    téléphones se trouvant dans le bâtiment où vous trouvez.

  • Appelez immédiatement votre fournisseur de gaz depuis

    un voisin. Suivez les instructions du fournisseur.

  • Si vous ne pouvez rejoindre le fournisseur de gaz,

    appelez le service des incindies.

L

’installation et l’entretien doivent être assurés par un

  installateur ou un service d’entretien qualifié ou par le

  fournisseur de gaz.

Intertek Report No. 

100404899PRT-001

Based on CSA P.4.1-02

Look for the 

EnerGuide

Gas Fireplace Energy

Efficiency Rating in this manual.

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l’appareil.

CONSOMMATEUR : Conservez cette notice pour 

consultation ultérieure.

LDV42N             LDV42P

LDV54N             LDV54P

Содержание ELITE LDV42N

Страница 1: ...is or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from...

Страница 2: ...allation Instructions this manual Care and Operation Instructions Safety in Operation Warnings Warranty Vent restrictor assembly Remote control kit handheld remote control transmitter remote control r...

Страница 3: ...proper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning Do not attempt to alter or modify the construction of the applianc...

Страница 4: ...e ON OFF function only Efficiencies Fireplace Model Natural Gas Propane AFUE EnerGuide P4 AFUE EnerGuide P4 ldv42 66 7 54 2 69 6 59 4 ldv54 71 9 63 2 72 1 65 5 AFUE Annual Fuel Utilization Efficiency...

Страница 5: ...with certain vent runs 16 Reinstall baffle if removed for vent restrictor installation 28 Install media 27 Install glass door 29 12 Verify appliance operation 30 Lighting instructions 31 Air shutter a...

Страница 6: ...of the mantel UNPROTECTED Side Wall See Figure 6 4 for minimum clearances to unprotected side walls FINISH SURROUND IMPORTANT The factory supplied non com bustible fiber board MUST be installed aroun...

Страница 7: ...fireplace the nailing flanges MUST be adjusted according to finish cleanface or surround and wall finish material thickness This is critical to ensure proper fireplace location especially if installi...

Страница 8: ...or dimension information only Fireplace must be adequately framed and supp A Required frame opening width 1 2 of A horizontal centerline of fireplace and vent framing opening B Required frame opening...

Страница 9: ...vertical position for cleanface finish and at 1 2 wall finish depth Cleanface Finish Nailing Flange Settings 1 Leave vertical position of nailing flanges at factory setting see Figure 9 1 DETAIL A 2 I...

Страница 10: ...opane tank smaller than 100 lbs may create pressure loss and insufficient fuel delivery which can cause sooting severe delayed ignition or other malfunctions ref NPFA 58 Any damage as a result of insu...

Страница 11: ...alified installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter Figure 11 3 Gas Stub 1 2...

Страница 12: ...t all factory and field connections for gas leaks Note Even though soapy water is an effective leak test solution it is NOT recommended because soap residue can corrode pipes and fittings over time 1...

Страница 13: ...against the adjoining section until fully engaged 3 Twist the section being attached CLOCK WISE running the dimples down and along the channels until seated at the ends of the channels The sections ar...

Страница 14: ...L 2 1 4 2 1 0 1 2 1 2 2 2 1 4 3 2 1 6 4 t n e V f o t h g i e H s n o i t c e S t n e V f o r e b m u N s e h c n i t f 6 7 2 3 2 0 0 0 8 0 8 9 7 2 5 2 3 2 0 0 0 0 6 6 5 0 8 2 5 7 3 3 2 1 0 0 8 0 9 5...

Страница 15: ...bove appliance vent outlet VENT RUN SUPPORT REQUIREMENTS Supporting Vertical Vent Runs Note Proper venting support is very important NEVER use the fireplace to support the weight of the venting Suppor...

Страница 16: ...o slide the assembly up into the vent collar as shown in Figure 16 3 The vent restrictor is held in place by fric tion only The entire vent restrictor assembly must be up inside the vent collar with n...

Страница 17: ...ofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 inch from the end 3 Pull and extend the inner flexible vent pipe 4 Slidetheinnerflexpipeov...

Страница 18: ...provided Vent Restrictor if re quired see Page 16 A 90 elbow may NOT be attached directly to the appliance collar A minimum of 6 pipe must be used between the fireplace collar and a 90 elbow For more...

Страница 19: ...screw c Apply non combustible caulking silicone caulking is acceptable around entire cir cumference to ensure a water tight seal LENNOX HEARTH PRODUCTS ELITE LINEAR VIEW DIRECT VENT GAS FIREPLACE MODE...

Страница 20: ...rtical Firestop Spacer must be used anywhere vent pipe passes through a combustible floor or ceiling Horizontal Firestop Spacer must be used anywhere vent pipe passes through a combustible wall For fu...

Страница 21: ...termination must have a minimum 6 152 mm clearance to any overhead combustible projection less than or equal to 2 1 2 64 mm For projections greater than 2 1 2 64 mm see Figure 21 1 For additional vent...

Страница 22: ...U S 12 in Canada V L B J X V A G Inside Corner Detail B C C C 18 Ventilated Soffit Horizontal Termination Detail D Exterior Wall 6 Inside Corner See Item D in the Text Below V P V O N N Q NOTE Local...

Страница 23: ...Attach termination adaptor See Figure 23 2 Attach the termination adaptor provided with the termination to the vent section or telescoping vent section or elbow in the same manner as the other vent co...

Страница 24: ...1PH Junction Box Field Wired Factory Wired Power Supply Unswitched CAUTION Ground supply lead must be con nected to the wire attached to the green ground screw located on the outlet box Failure to do...

Страница 25: ...can turn on suddenly Keep away from the appliance burner when operating the remote system or activating manual bypass of the remote system CAUTION Propertydamagehazard Excessive heat can cause propert...

Страница 26: ...is turned off The receiver beeps 2 times Low Battery Detection Remote Control The life of the Remote Control batteries depends on many factors including battery quality and number of appliance ignitio...

Страница 27: ...complete combus tion sooting and poor flame quality and will void the warranty Rear Floor Section Rear Ledge Tab Side Panel Center Lower Tab Reinstall front floor section 1 See Figure 27 2 Engage lowe...

Страница 28: ...allelectricitytotheappliancebeforeinstallingmedia If media is not installed according to the installation instructions flame impingement and improper combustion could occur resulting in soot This appl...

Страница 29: ...tempt to substitute the materials used on these doors or replace cracked or broken glass The glass door s of this appliance must onlybereplacedasacompleteunitaspro vided by the manufacturer Do not att...

Страница 30: ...re also provided on a tag attached to one of the lower door brackets When first lighting the appliance it will take a few minutes for the gas line to purge itself of air Once purging is complete the p...

Страница 31: ...tools Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance...

Страница 32: ...Guidelines If there is smoke or soot present first ensure that the flames are not impinging on any of the panels If the panels are properly posi tioned and a sooting condition still exists increase t...

Страница 33: ...ES Make sure TOP and BOTTOM Nailing Flanges are attached to fireplace in the correct VERTI CAL position for Surround finish and the correct HORIZONTAL position for the wall finish material thickness s...

Страница 34: ...rd abuts lip Combustible Wall Finish Material Top Non Combustible Fiber Board provided with fireplace Wall Stud Insulation and combustible material NOT ALLOWED in clearance zones around vent component...

Страница 35: ...rez la t l commande et nettoyez la soigneuse ment pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur le bo tier de la t l commande Figure B Choisissez la langue qui es...

Страница 36: ...4 5VF 10 Firestop Spacer Vertical rigid 1 1 1 spacing 10 pk 96K92 SV4 5SP Support Plate Vent Sections Rigid Listed Secure Vent Components Cat Model Description 17M52 SV4 5HGS 1 TerminationGuard Square...

Страница 37: ...sedflex 77L89 SFKIT24S Horiz Termination forflex with24inch 610 mm compressedflex 77L90 SFKIT36S Horiz Termination forflex with36inch 914 mm compressedflex 77L91 SFKIT48S Horiz Termination forflex wit...

Страница 38: ...ever use substitute materials Use of non approved parts can result in poor performance and safety hazards and may void the warranty Parts with item numbers are illustrated on the next page Item No Des...

Страница 39: ...are those listed on the previous page LENNOX HEARTH PRODUCTS ELITE LINEAR VIEW DIRECT VENT GAS FIREPLACE MODELS LDV42 LDV54 INSTALLATION INSTRUCTIONS 25 1 67 5 D B R E V 00 4 Power 120V Out Fan Aux O...

Страница 40: ...eserves the right to make changes at any time without notice in design materials specifications and prices and also to discontinue colors styles and products Consult your local distributor for firepla...

Отзывы: