NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

SV4.5HT-2

Termination

SV4.5FA OR
SV4.5FB Flashing
AND SV4.5SC
STORM COLLAR

*SV4.5VF
Firestop/Spacer

SV4.5L6/12/24/36/48
Vent Sections

40' Max.
(12.2 M)

6' Min.

(1.8 M)

1" (25.4 mm)
Minimum
Clearance to
Combustibles

*When using Secure Flex,

use Firestop/Spacer

SF4.5VF

Figure 13

Step 3. INSTALL THE VENT SYSTEM

General Information

These instructions should be used as a guide-
line and do not supersede local codes in any
way. Install vent according to local codes,
these instructions, the current National Fuel
Gas Code (ANSI-Z223.1) in the USA or the
current standards of CAN/CGA-B149.1 and -
B149.2 in Canada.

These fireplaces are designed, tested
and listed for operation and installation
with, and only with, Secure Vent
™   Direct
Vent System Components, Secure Flex

Flexible Vent Components manufactured
by Security Chimneys International and
Z-FLEX
™  Model GA Venting Systems
listed to UL1777 and ULCS635 manufac-
tured by Flexmaster Canada Limited.
These approved vent system components
are labeled for identification. 

 DO NOT

use any other manufacturer's vent com-
ponents with these appliances.

These fireplaces must be vented directly
to the outside.

Determine the venting for the appliance.  If the
vent run will include at least 8 feet of vertical
rise, then install the  second restrictor in the
appliance collar before connecting any vent
(Refer to 

Figure 12 ).  Place the second restric-

tor inside the fixed restrictor.

Note:  The second restrictor is included within
the firebox.

Vertical (Straight) Installation

Determine the number of straight vent sec-
tions required. 4-1/2" (114 mm), 10-1/2" (267
mm), 22-1/2" (572 mm), 34-1/2" (876 mm)
and 46-1/2" (1181 mm) net section lengths are
available. Plan the vent lengths so that a joint
does not occur at the intersection of ceiling or
roof joists.  Refer to the Vent Section Length
Chart.

The vent system may not service multiple
appliances, and must never be connected to a
flue serving a solid fuel burning appliance. The
vent pipe is tested to be run inside an enclos-
ing wall (such as a chase). There is no require-
ment for inspection openings in the enclosing
wall at any of the joints in the vent pipe.

Select Venting System - Horizontal or Vertical

With the appliance secured in framing, deter-
mine vent routing and identify the exterior
termination location. The following sections
describe vertical (roof) and horizontal (exterior
wall) vent applications. Refer to the section
relating to your installation. A list of approved
venting components is shown in the tables on
page 26.

VERTICAL TERMINATION SYSTEMS (ROOF)

Figures 13, and 23 through 25 on pages 14
and 15
 and their associated Vertical
Vent Tables illustrate the various vertical vent-
ing configurations that are possible for use with
these appliances.  Secure Vent pipe applica-
tions are shown in these figures; Secure Flex
pipe may also be used.

A Vertical Vent Table summarizes each system’s
minimum and maximum vertical and horizontal
length values that can be used to design and
install the vent components in a variety of
applications.

Both these vertical vent systems terminate
through the roof. The minimum vent height
above the roof and/or adjacent walls is speci-
fied in ANSI Z223.1-(latest edition) (In Canada,
the current CAN-1 B149 installation code) by
major building codes. Always consult your
local codes for specific requirements. A gen-
eral guide to follow is the Gas Vent Rule (refer
to 

Figure 4 on page 6 ).

Figure 12

Exhaust Vent

Fixed
Restrictor

Second
Restrictor

Содержание Elite ELDV-35NE

Страница 1: ...terrupteur Nepasvousservir des t l phones se trouvant dans le batiment o vous vous trouvez Evacuez la pi ce le b timent ou la zone Appelez imm diatement votre fournisseur de gaz depuis un voisin Suive...

Страница 2: ...l compartment cover strapped to the top of the unit GENERAL INFORMATION Note Installation and repair should be per formed by a qualified service person The appli ance should be inspected annually by a...

Страница 3: ...r use with other gases unless a certified kit is used Cet appareil peut tre install dans un maison pr fabriqu e U seulement ou mobile d j install e demeure si les r glements locaux le permettent Cet a...

Страница 4: ...itioning ducting Thesedirectventappliancesareuniquelysuited for installations requiring a utility shelf posi tioneddirectlyabovethefireplace Utilityshelves like these are commonly used for locating te...

Страница 5: ...Vertical Wall Vent Termination Storm Collar Concentric Vent Pipe Flashing 1 inch 25 4 mm Minimum Clearance to Combustibles h c t i P f o o R H t e e f 2 1 6 o t t a l F 0 1 2 1 7 o t 2 1 6 r e v O 5...

Страница 6: ...arance to combustible framing mem bers as shown in Table 2 on page 4 Iftheapplianceistobeelevatedabovefloorlevel asolidcontinuousplatformmustbeconstructed Headers may be in direct contact with the app...

Страница 7: ...i l r e t n e c f o e d i s n i h c a e o t e c n a r a e l C H y l b m e s s a r o t a l u g e r r e t e m e v o b a d e d n e t x e t e e f 5 1 f o t h g i e h a n i h t i w m c 1 9 t e e f 3 y l b...

Страница 8: ...e constructed of 2x4 or larger lumber Inches mm 130 C is the required framing depth dimension when the finish material drywall thickness is 1 2 in 13mm A C l e d o M o N A B C D E 5 3 V D L E n i 6 1...

Страница 9: ...N A B C D E F G H 5 3 V D L E n i 8 1 0 4 8 1 7 3 8 5 5 2 8 1 9 2 8 1 5 3 2 1 1 2 4 3 0 1 2 1 2 3 m m 1 9 0 1 3 4 9 1 5 6 0 4 7 2 9 8 6 4 5 3 7 2 5 2 8 0 4 V D L E n i 8 1 0 4 8 1 7 3 8 5 5 2 8 1 4 3...

Страница 10: ...6 mm and 46 1 2 1181 mm net section lengths are available Plan the vent lengths so that a joint does not occur at the intersection of ceiling or roof joists Refer to the Vent Section Length Chart The...

Страница 11: ...1 0 0 0 5 6 5 1 4 2 5 2 1 0 2 0 0 0 7 0 7 6 4 2 5 0 2 1 0 0 7 0 8 2 5 2 1 2 0 1 0 7 0 8 4 6 2 2 2 0 0 1 7 0 8 6 7 2 3 2 0 0 0 8 0 8 9 7 2 5 2 3 2 0 0 0 0 6 6 5 0 8 2 5 7 3 3 2 1 0 0 8 0 9 5 3 8 2 5 2...

Страница 12: ...ngth may be used to secure the support straps to the vent pipe See Figure 17 Push the vent component against the collar untilitfullyengages thentwistthecomponent clockwise runningthedimplesdownandalon...

Страница 13: ...is of their initial collar section to align with the required direction of the next vent run element Twist elbow sections in a clockwise direction only so as to avoid the possiblity of unlocking any o...

Страница 14: ...ee el bows are used Note It is very important that the horizontal inclined run be maintained in a straight no dips and recommended to be in a slightly elevated plane in a direction away from the firep...

Страница 15: ...using Secure Flex use Firestop Spacer SF4 5HF Min One Foot Vent Section Required B E L B A T V M M U M I N I H H 1 m u m i x a M t e e f m t e e f m 2 1 0 6 0 5 4 2 5 1 3 4 1 9 0 0 1 1 3 4 2 2 1 5 1 5...

Страница 16: ...sections On the vertical run support the venting sys tem every 8 feet 2 4m above the fireplace vent outlet with field provided support straps Plumber s tape Attach the straps to the vent pipe and secu...

Страница 17: ...ttached see Figure 28 Iftheterminusofthelastsectionisnotwithinthis distance use the telescopic vent section SV4 5LA as the last vent section For wall thick nesses greater than that shown in Figure 28...

Страница 18: ...nt SF4 5HF SecureFlex firestop spacermustbeused anytime vent pipe passes through a combustible wall Note Secure Vent components rigid vent pipe and terminal are shown inthefigures SecureFlexcomponents...

Страница 19: ...m u m i x a M H t e e f m t e e f m 2 1 0 6 0 4 1 3 1 9 9 0 3 4 1 9 0 5 7 6 8 2 2 4 2 2 1 4 3 0 1 6 7 2 3 5 4 2 5 1 4 1 7 6 2 4 6 9 2 7 1 4 1 7 1 8 5 2 5 7 4 3 1 2 0 2 2 6 x a M m 4 2 1 t e e f 0 4 H...

Страница 20: ...nd of the adapter over the previously installed section or appli ance collar adjusting the radial alignment until the four locking dimples of the adapter are aligned with the inlets of the four inclin...

Страница 21: ...s red pigtail lead and the white power supply wire to the common terminal of the outlet as shown in Figure 35 5 Connectthegroundsupplywiretothepigtail lead attached to outlet s green ground screw 6 A...

Страница 22: ...cess plate opening Bring the shutoff valve on the end of the flex line over to the hard pipe and tighten with wrenches from above through the firebox opening If required access the valve by removing t...

Страница 23: ...ening using the provided screws 4 as shown in Figure 37 Referto Figure41andloosenthesetscrewfor the venturi air shutter Manually actuate the air shutter through several cycles Set the air shutter to 3...

Страница 24: ...s shown in the table in Figure 41 Allow the burner to operate for at least 20 minutes WARNING AIR SHUTTER ADJUST MENT SHOULD ONLY BE PER FORMED BY A QUALIFIED PROFES SIONAL SERVICE TECHNICIAN IMPORTAN...

Страница 25: ...b a sheet of plywood or other raised platform can be placed underneath to prevent conducting cold up into the room It also helps to sheetrock inside surfaces and tape for maximum air tightness and cau...

Страница 26: ...e d u l c n i s t i k n o i t a n i m r e t e s e h T 9 6 9 1 H 2 T H 5 4 F S n o i t a n i m r e T e r a u q S l a t n o z i r o H x e l F t u o h t i w 7 8 L 7 7 2 1 T I K F S n i 2 1 h t i w m r e...

Страница 27: ...FIED SERVICE AGENCY IN ACCORDANCE WITH THE MANUFACTURER S IN STRUCTIONS AND ALL APPLICABLE CODES AND REQUIREMENTS OF THE AUTHORIZED HAVING JURISDICTION IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT...

Страница 28: ...Turn on gas supply and test for gas leaks All Models Step 8 Refer to Figure 45 on page 27 A Remove the orifice from the manifold and replace it with the one provided in the kit See the following table...

Отзывы: