background image

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

11

Figure 3

MOUNTING THE APPLIANCE - continued

Before  tightening  the  wall-mounting  screws  fully,  at  this  stage  it  is 

recommended to check the horizontal alignment of the appliance with 

a spirit level, as small adjust ments can still be made if necessary . When 

this has been checked, tighten all four fixing screws fully .  

To access the upper fixing screws insert a screwdriver either through 

the round holes in the front of the outlet Grill (as shown in Figure 3), or 

alternatively for easier access the outlet Grill may be removed and the 

fixing screws accessed more directly through the holes in the deflector 

baffle as shown in Figure 4 .

CHECKING THE BURNER

There  are  no  imitation  fuel  bed  components,  such  as  logs  or  rocks, 

to install . The appliance features a ribbon burner which is designed to 

produce a continuous band of flame over its length . The burner should 

be visually inspected to ensure it is free from any foreign matter . If it is 

necessary to clean or dust off the burner then the glass door should be 

removed by removal of the four retaining screws . Re-fit the glass door 

after cleaning or inspection, ensuring a good seal .

A qualified gas appliance installer must connect the gas room heater to 

the gas supply . Consult all local codes . 

The installer must provide an ANSI approved manual shut off valve, flex 

connector and 3/8” NPT fitting . A flex gas line kit with shut-off valve is 

available (see Page 18 for ordering information) .

Route gas line using techniques and materials prescribed by local and/

or national codes . Only use pipe of 1/2” or greater diameter to allow full 

gas volume to the gas fireplace . Undue pressure loss will occur if the 

pipe is too small .

An external regulator must be used on all propane (L .P .G .) heaters, in 

addition to the regulator fitted to the heater, to reduce the supply tank 

pressure to 13” w .c . (maximum) .

CONNECTING A GAS LINE

      WARNING 

Connecting directly to a unregulated propane tank 

may cause an explosion.

An ANSI approved manual shut-off valve and union must be installed 

upstream  of  the  heater  within  the  fireplace  cavity  when  rigid  pipe  is 

used . Ensure that a sediment trap is installed upstream of the heater 

(Figure  5)  within  the  structure’s  piping  system  to  prevent  moisture 

and contaminants from passing through the pipe to the heater controls 

and burner . Failure to do so could prevent the heater from operating 

reliably . The heater gas inlet connection is 3/8” NPT at the regulator, 

located below the burner, in the center of the heater . When tightening 

up the joint to the regulator hold the regulator securely with a wrench 

to prevent the regulator from moving . 

Figure 4

Regulator

Manual 

Shut-Off

Valve

Union

Sediment

Trap

Fireplace or

Firebox Wall

Wall

Shut-Off

Key

Fireplace or

Firebox Wall

Down

3”

Figure 5

      IMPORTANT 

Hold heater regulator with a wrench to prevent move-

ment when connecting to inlet piping.

NOTE:  See Page 21 for gas line entry point dimensions.

Содержание Elite CVF - LP

Страница 1: ...ppelez le service des incindies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz AVERTISSEMENT Assurez vousdebiensui...

Страница 2: ...instructions will help ensure many years of dependable and enjoyable service from your fireplace Register your product online today To help us keep you up to date on product information and offers ple...

Страница 3: ...ge 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el contacto directo con el vidrio y prevenir las quemaduras...

Страница 4: ...vec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cette...

Страница 5: ...pliance is Not convertible for use with other gases These appliances are designed to operate on natural gas or propane gas only The use of other fuels or combinations of fuels will degrade the perform...

Страница 6: ...reshowninBTUperhourandareforelevations up to 4 500 feet Do not install this heater at an elevation above 4 500 feet if the gas supply has not been derated for thatelevation Consultyourlocalgassupplier...

Страница 7: ...DE FOR ALLOWABLE DISTANCES CODES Adhere to all local codes or in their absence the latest edition of The National Fuel Gas Code ANSI Z223 1 or NFPA 54 which can be obtained from The American National...

Страница 8: ...___ volume of space ft3 50 ft3 Maximum BTU Hr the space can support Example 3072 ft3 50 ft3 61 44 or 61 440 BTU Hr the space can support 3 Add the BTU Hr of all the fuel burning appliances in the spac...

Страница 9: ...esigned to be wall mounted alone and not in conjunction with any type of combustible fire surround No combustible shelves should be positioned on the wall above the appliance It should be established...

Страница 10: ...mounted on a dry lined wall or a timber framed construction wall then special cavity screw fixings will be required which are not supplied with this product These should be constructed from metal and...

Страница 11: ...and 3 8 NPT fitting A flex gas line kit with shut off valve is available see Page 18 for ordering information Route gas line using techniques and materials prescribed by local and or national codes On...

Страница 12: ...urner Make sure all ports are open and producing flame evenly across the burner If any ports are blocked or partially blocked clean out the ports The heater regulator controls the burner pressure whic...

Страница 13: ...g up with the appropriate hole Release the assembly when in position and secure in place by refitting the front clamping disc BRIEFING THE CUSTOMER WARNING Do not add logs or ornaments such as pine co...

Страница 14: ...to ensure the spark gap is correct See specifications for gas setting NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY LIT If the pilot will not stay lit there is a problem with dirt the...

Страница 15: ...als are in good condition before replacing the catalyst New seals will usually be required The performance of the catalyst may be checked using a combustion gas analyzer as follows Important The tempe...

Страница 16: ...above If you do not smell gas go to next step 5 The pilot is located on the left side behind the burner Figure 13 6 Depress control knob in and turn counter clockwise to the SPARK position Figure 13...

Страница 17: ...m with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY...

Страница 18: ...NTILLA ANTES DE COLOCAR LE APARATO WARNING CLEARANCES FROM COMBUSTIBLE MATERIALS F860041 A The following clearances must be maintained at all times Failure to do so may result in the risk of a fire Fo...

Страница 19: ...POSITIONING OF FIELD REMOVABLE PARTS Outlet Grill Main Firebox Assembly Valve Cover Plate Control Knob Spindle Control Knob Burner Assembly Burner Cover Plate Glass Door Assembly As our policy is one...

Страница 20: ...NOT TO SCALE SPECIFICATIONS Elite CVF 6 1 4 23 7 8 27 3 16 9 3 16 20 1 4 Back View Top View Front View Product Reference Information Cat No Model Ship Wt Ship Volume H6072 Elite CVF NG 50 lb 4 3 cu ft...

Страница 21: ...arest 1 16 KEY D1 Distance from mounting surface to rear entry point D2 Distance from mounting surface to center of side entry point D3 Distance from mounting surface to regulator gas entry point GAS...

Страница 22: ...r Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance...