background image

16

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY

RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.

  

 This appliance has a pilot which must be lit with a piezo 
spark igniter. When lighting the pilot, follow these instructions 
exactly.

B.

  

 BEFORE OPERATING smell all around the heater area for gas. 
Be sure to smell next to the floor because some gas is heavier 
than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

 

• Do not try to light any appliance.

 

•  Do not touch any electric switch; do not use any phone in your 

building.

 

• Immediately call your gas supplier from a neighbor’s phone.    

                   Follow the gas supplier’s instructions.

 

• If you cannot reach your gas supplier, call the fire department.

C.

  

Use only your hand to push in or turn the gas control knob.

 

 Never use tools. If the knob will not push in or turn by hand, do 
not try to repair it, call a qualified service technician. Forced or 
attempted repair may result in a fire or explosion.

D.

  

Do not use this heater if any part has been under water.

 

 Immediately call a qualified service technician to inspect the 
appliance and to replace any part of the control system and any 
gas control which has been under water.

LIGHTING INSTRUCTIONS

1. Stop! Read the safety information above.

2. Make sure manual shut-off valve is fully open.

3. Depress control knob in and turn clockwise                     to the
”OFF” position

 (Figure 13)

.

4. Wait 5 minutes to clear out any gas. Then smell for gas, including near 
the floor. If you smell gas, STOP! Follow the safety instructions in ”What 
to do if you smell gas” under section ‘B’ above. If you do not smell gas, go 
to next step.

5. The pilot is located on the left side behind the burner 

(Figure 13)

.

6. Depress control knob in and turn counter-clockwise                    to the 
”SPARK” position 

(Figure 13)

 and hold there for a few seconds.

Note: If you are running the heater for the first time or after an extended 
period of non use it will be necessary to press the control knob all the way 
in for 30 seconds to allow air to bleed out of the gas piping.

7. Continue turning counter-clockwise                        through the spark click 
to the PILOT light position, ensuring the pilot has lit. If not, turn the knob 
fully clockwise,                  and repeat.

8. Hold the control knob in for a further 10 seconds to prevent the flame 
failure detector from shutting off the gas while the probe is warming up.

9. Release the control knob while turning counter-clockwise                                
to the preferred setting. Close  the control access panel.

• If the knob does not pop out when released, stop and immediately call 
your service technician or gas supplier.

• If the pilot will not stay lit after several tries, depress and turn the gas 
control knob clockwise                      to ”OFF” and wait 30 seconds. 
Depress and turn knob counter-clockwise                       to ”SPARK” 
and ignite the heater again. If your pilot does not relight depress and 
turn control knob clockwise                      to ”OFF” and call your service 
technician or gas supplier.

10. Wait 30 seconds before readjusting the heater when the control knob 
has been turned down to a lower setting.

TO TURN OFF GAS TO APPLIANCE

1. Depress and turn control knob clockwise                      to the ”OFF” 
position 

(Figure 13).

 

Figure 14: Pilot assembly . This is located 

behind the burner, on the left-hand side of 

the appliance .

Figure 14

The control knob is located on the lower 

right hand side of the outer case . It is 

marked as shown in Figure 13 .

‘OFF’ position

‘SPARK’ position

‘LOW’ position

‘HIGH’ position

Figure 13

LIGHTING INSTRUCTIONS & TURNING OFF APPLIANCE

Содержание Elite CVF - LP

Страница 1: ...ppelez le service des incindies L installation et l entretien doivent tre assur s par un installateur ou un service d entretien qualifi ou par le fournisseur de gaz AVERTISSEMENT Assurez vousdebiensui...

Страница 2: ...instructions will help ensure many years of dependable and enjoyable service from your fireplace Register your product online today To help us keep you up to date on product information and offers ple...

Страница 3: ...ge 4 Toutes les parties de votre foyer Lennox Hearth Products deviennent EXTR MEMENT CHAUDES Instale una malla o barrera f sica para evitar el contacto directo con el vidrio y prevenir las quemaduras...

Страница 4: ...vec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le installez une barri re de s curit cette...

Страница 5: ...pliance is Not convertible for use with other gases These appliances are designed to operate on natural gas or propane gas only The use of other fuels or combinations of fuels will degrade the perform...

Страница 6: ...reshowninBTUperhourandareforelevations up to 4 500 feet Do not install this heater at an elevation above 4 500 feet if the gas supply has not been derated for thatelevation Consultyourlocalgassupplier...

Страница 7: ...DE FOR ALLOWABLE DISTANCES CODES Adhere to all local codes or in their absence the latest edition of The National Fuel Gas Code ANSI Z223 1 or NFPA 54 which can be obtained from The American National...

Страница 8: ...___ volume of space ft3 50 ft3 Maximum BTU Hr the space can support Example 3072 ft3 50 ft3 61 44 or 61 440 BTU Hr the space can support 3 Add the BTU Hr of all the fuel burning appliances in the spac...

Страница 9: ...esigned to be wall mounted alone and not in conjunction with any type of combustible fire surround No combustible shelves should be positioned on the wall above the appliance It should be established...

Страница 10: ...mounted on a dry lined wall or a timber framed construction wall then special cavity screw fixings will be required which are not supplied with this product These should be constructed from metal and...

Страница 11: ...and 3 8 NPT fitting A flex gas line kit with shut off valve is available see Page 18 for ordering information Route gas line using techniques and materials prescribed by local and or national codes On...

Страница 12: ...urner Make sure all ports are open and producing flame evenly across the burner If any ports are blocked or partially blocked clean out the ports The heater regulator controls the burner pressure whic...

Страница 13: ...g up with the appropriate hole Release the assembly when in position and secure in place by refitting the front clamping disc BRIEFING THE CUSTOMER WARNING Do not add logs or ornaments such as pine co...

Страница 14: ...to ensure the spark gap is correct See specifications for gas setting NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY LIT If the pilot will not stay lit there is a problem with dirt the...

Страница 15: ...als are in good condition before replacing the catalyst New seals will usually be required The performance of the catalyst may be checked using a combustion gas analyzer as follows Important The tempe...

Страница 16: ...above If you do not smell gas go to next step 5 The pilot is located on the left side behind the burner Figure 13 6 Depress control knob in and turn counter clockwise to the SPARK position Figure 13...

Страница 17: ...m with dirt the gas supply or the thermocouple needs replacement Modifications are dangerous and can have a serious unseen effect on safety NEVER MODIFY OR BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY...

Страница 18: ...NTILLA ANTES DE COLOCAR LE APARATO WARNING CLEARANCES FROM COMBUSTIBLE MATERIALS F860041 A The following clearances must be maintained at all times Failure to do so may result in the risk of a fire Fo...

Страница 19: ...POSITIONING OF FIELD REMOVABLE PARTS Outlet Grill Main Firebox Assembly Valve Cover Plate Control Knob Spindle Control Knob Burner Assembly Burner Cover Plate Glass Door Assembly As our policy is one...

Страница 20: ...NOT TO SCALE SPECIFICATIONS Elite CVF 6 1 4 23 7 8 27 3 16 9 3 16 20 1 4 Back View Top View Front View Product Reference Information Cat No Model Ship Wt Ship Volume H6072 Elite CVF NG 50 lb 4 3 cu ft...

Страница 21: ...arest 1 16 KEY D1 Distance from mounting surface to rear entry point D2 Distance from mounting surface to center of side entry point D3 Distance from mounting surface to regulator gas entry point GAS...

Страница 22: ...r Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance...

Отзывы: