17
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 16 - Wiring Diagram - Electronic Gas Valves
P/N 580491-01
JUNCTION BOX
120V AC
REMOTE RECEIVER
ON/OFF SWITCH
WALL SWITCH
LIMIT SWITCH
B-VENT MODELS
ONLY
AC/DC
POWER
ADAPTOR
HOT
NEUTRAL
OPTIONAL
GROUND
BATTERY HOLDER
DFC WIRE HARNESS
SPARK WIRE CABLE
PILOT GROUND WIRE
PILOT
SENSOR
CABLE
HOOD
IGNITER ROD
FLAME SENSOR
PILOT TUBE
OPTIONAL CPI SWITCH
OFF (O) = INTERMITTENT PILOT MODE
ON (-) = STANDING PILOT MODE
PROFLAME DFC BOARD
PROFLAME VALVE
ELECTRONIC PILOT ASSEMBLY
B = BLACK
BR = BROWN
GY = GRAY
PU = PURPLE
R = RED
BL = BLUE
G = GREEN
O = ORANGE
W = WHITE
Y = YELLOW
WIRING COLOR CODE
B
B
B
R
R
W
W
B
B
B
B
BL
BL
G
G
O
Y
Y
R
R
Y
W
G
G
O
SCHEMATIC REPRESENTATION ONLY
Figure 15
ATTENTION: AU MOMENT DE
L'ENTRETIEN DES COMMANDES,
ÉTIQUETEZ TOUS LES FILS AVANT DE
LES DÉBRANCHER. DES ERREURS
DE CÁBLAGE PEU-VENT ENTRAÎNER
UN FONCTIONNEMENT INADÉQUAT
ET DANGEREUX.
LENNOX HEARTH PRODUCTS
1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
visit us at www.LennoxHearthProducts.com
1-800-655-2008
PRODUCT REFERENCE INFORMATION
We recommend that you record the following
important information about your fireplace.
Please call Lennox Hearth Products for the
phone number of your nearest Lennox Hearth
Products dealer who will answer your questions
or address your concerns.
Your Fireplace's Model Number ___________________________________________
Your Fireplace's Serial Number ___________________________________________
The Date On Which Your Fireplace Was Installed ______________________________
The Type of Gas Your Fireplace Uses _______________________________________
Your Dealer's Name ___________________________________________________
Parts will be shipped at prevailing prices at
time of order.
When ordering repair parts, always give the
following information:
1.
The model number of the appliance.
2.
The serial number of the appliance.
3.
The part number.
4.
The description of the part.
5.
The quantity required.
6.
The installation date of the appliance.
If you encounter any problems or have any
questions concerning the installation or ap-
plication of this system, please contact your
dealer or distributor.
REPLACEMENT PARTS
A complete parts list is found at the end of
this manual. Use only parts supplied from the
manufacturer.
With proper care and maintenance, your appli-
ance will provide many years of enjoyment. If
you should experience any problem, first refer
to the troubleshooting guide in this manual. If
problem persists, contact your Lennox Hearth
Products dealer or distributor.
Normally, all parts should be ordered through your
Lennox Hearth Products distributor or dealer.
Thermopile
TH
TP
TH
TP
Millivolt Wiring Diagram
If any of the original wire as supplied must be replaced,
it must be replaced with
Type AWM 105
º
C – 18 GA. wire.
*OR OPTIONAL WALL-MOUNTED ON/OFF SWITCH
OR OPTIONAL THERMOSTAT
OR OPTIONAL REMOTE CONTROL RECEIVER
Factory Wired
Field Wired
Schematic Representation Only
APPLIANCE-MOUNTED ON/OFF SWITCH
*Turn the appliance-mounted ON/OFF burner control switch
to the OFF position if an optional
control switch is installed.
WIRING DIAGRAMS
Wiring diagrams are provided here for reference
purposes only. This information is also provided
on schematics attached directly to the appliance
on a pullout panel located within the control
compartment.
CAUTION: LABEL ALL WIRES PRIOR TO
DISCONNECTION WHEN SERVICING
CONTROLS. WIRING ERRORS CAN
CAUSE IMPROPER AND DANGEROUS
APPLIANCE OPERATION.
Содержание EDV35RNE