22
MAINTENANCE SCHEDULE
Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
Annually
(Before the onset of the Burning Season)
MAINTENANCE TASK
ACCOMPLISHING PERSON
PROCEDURE
Inspect/Clean Burner, Logs
and Controls
Qualified Service Technician
Inspect valve and ensure it is properly operating. Check piping for
leaks. Vacuum the control compartment, fireplace logs and burner area.
Check Flame Patterns and Flame Height Qualified Service Technician
Refer to
Figures 9 (EDV35), 10 (EDV40) or 11 (EDV45) on Page 15
and
verify the flame pattern and height displayed by the appliance conforms
to the picture. Flames must not impinge on the logs. Ensure flames
are steady (not lifting or floating).
Inspect/Clean Pilot and Burner
Qualified Service Technician
Refer to
Figure 13 (Millivolt) or Figure 14 (Electronic) on Page 16
.
Remove any surface build-up on pilot and burner assembly. Wipe the
pilot nozzles, igniter/flame rod and hood. Ensure the pilot flame engulfs
the flame sensor as shown.
Check Vent System
Qualified Service Technician
Inspect the vent system at the top and at the base (within the firebox) for
signs of blockage or obstruction.
Look for any signs of dislocation or
deterioration of the vent components
(reconnect or replace as necessary).
NOTE:
Excessive condensation can cause corrosion of caps, pipe & fit-
tings (excessive condensation can be caused by long lateral runs, too
many elbows, and/or exterior portions of the system being exposed to
cold weather). Also, inspect the wall straps or plumbers's tape to ensure
they are securely in place.
Appliance Checkout
Qualified Service Technician
Perform the appropriate appliance checkout procedure detailed in this
manual.
Replace Glowing Embers
Homeowner/Qualified Service
Technician
Remove old
glowing ember
materials and vacuum the
ember
placement
area. Place new
embers per instructions on
Page 12.
Periodically
(After the Burning Season)
MAINTENANCE TASK
ACCOMPLISHING PERSON
PROCEDURE
Clean Firebox Interior
Homeowner
Carefully remove logs, glowing embers and volcanic stone. Vacuum
out interior of the firebox. Clean firebox walls and log grate. Replace
logs, glowing embers and volcanic stone as detailed in this manual.
Check Flame Patterns and Flame Height Homeowner
Refer to Refer to
Figures 9 (EDV35), 10 (EDV40) or 11 (EDV45) on Page
15
and verify the flame pattern and height displayed by the appliance
conforms to the picture. Flames must not impinge on the logs.
Check Vent System
Homeowner
Inspect the vent system at the top and at the base (within the firebox)
for signs of blockage or obstruction. Look for any signs of dislocation
of the vent components
(reconnect or replace as necessary)
.
Clean Front Glass Enclosure Panel
Homeowner
Clean as necessary following the directions provided in this manual.