background image

13

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

WARRANTY

Your gas appliance is covered by a limited twenty 
year warranty. You will fi nd a copy of the war-
ranty accompanying this manual.  Please read 
the warranty to be familiar with its coverage.

Retain this manual. File it with your other docu-
ments for future reference.

REPLACEMENT PARTS

A complete parts list is found at the end of 
this manual. Use only parts supplied from the 
manufacturer.

Normally, all parts should be ordered through 
your Lennox distributor or dealer. Parts will be 
shipped at prevailing prices at time of order.

If you encounter any problems or have any ques-
tions concerning the installation or application 
of this system, please contact your distributor, 
or Lennox directly:

LENNOX HEARTH PRODUCTS
1110 West Taft Avenue 
Orange, CA  92865

PRODUCT REFERENCE INFORMATION

We recommend that you record the following im-
portant information about your fi replace.  Please 
contact your Lennox dealer for any questions 
or concerns.  For the number of your nearest 
Lennox dealer, please call 800-731-8101

Your Fireplace's Model Number ________________________________________

Your Fireplace's Serial Number ________________________________________

The Date On Which Your Fireplace Was Installed ___________________________

The Type of Gas Your Fireplace Uses ____________________________________

Your Dealer's Name   ________________________________________________  

When ordering repair parts, always give the 
following information:

1.

 The model number of the appliance.

2.

 The serial number of the appliance.

3.

 The part number.

4.

 The description of the part.

5.

 The quantity required.

6.

 The installation date of the appliance.

WIRING DIAGRAMS

Wiring diagrams are provided here for refer-
ence purposes only.  This information is also 
provided on schematics attached directly to the 
appliance on a pullout panel located within the 
control compartment. 

TH

TP

TH

TP

Thermopile

If any of the original wire as supplied must 
be replaced, it must be replaced with Type 
AWM 105

o

 C - 18 gage wire.

* Optional Kits Installed - OFF/ON wall switch, 
wall thermostat or remote control receiver. 
Note: Turn the appliance-mounted OFF/ON 
burner control switch to the OFF position if 
any of these kits are installed. 

Millivolt Wiring Diagram

Schematic Representation Only

Field Wired

Factory 
Wired

*Optional   Switch

Standard OFF/ON Switch

      CAUTION  

Label all wires prior to discon-
nection when servicing con-
trols.  Wiring errors can cause 
improper and dangerous appli-
ance operation.

Figure 16

Electronic Wiring Diagram (Honeywell) Showing Blower Wiring for Optional FBK-100, FBK-200 & FBK-250 Kits

Schematic Representation Only

G

BK

120
VAC

Relay Module C/W FBK-250 only. Plug blower 
into J-Box receptacle for FBK-100 or FBK-200 
application. View A for J-Box wiring.

Optional Blower

*OFF/ON Switch 
(Integral with 
Gas Valve)

Honeywell
Electronic
Gas
Valve

120 VAC
Primary

Secondary

Optional Control Switch

Junction
Box

Junction Box

Pilot Burner
Assembly

BL

BL

Wall Mounted Blower Speed Control Switch or 
ON/OFF Switch for Blower Kit (optional)

Field Wired
Factory 
Wired

BK = BLACK   BL = BLUE
R = RED         W = WHITE
G = GREEN

BK

W

BK

BK

BL

R

GROUND

24 V

Transformer

Auxiliary View A 
J-Box Wiring when 
using unit mounted 
relay module.

BK
W

G

C

A

0

2

1

Igniter
Connector

W

G BK

R

*  Leave the OFF/ON switch, which is 
integral with the gas valve, in the ON 
position.
**

Optional Control Switches

: Wall 

Switch, Wall Thermostat or Remote 
Control Receiver.

Notes:
1. If any of the original wire as supplied 
must be replaced, use Type AWM 105°C 
- 18 gage wire ONLY.
2. 120 VAC, 60 Hz - Less than 3 Amps.
Caution: label all wires prior to 
disconnection when servicing controls. 
Wiring errors can cause improper and 
dangerous operation.

White Wire 
to Opposite
Side (neutral)

Outlet Box Green 
Ground Screw

Break off Tab

Hot side
of Outlet

Figure 17

Содержание DIRECT VENT MERIT LMDV-33 SERIES

Страница 1: ...O NOT light any appliance DO NOT touch any electrical switches Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow your gas suppliers instructions I...

Страница 2: ...ns Millivolt Page 17 Lighting Instructions Electronic Page 18 Maintenance Schedule Page 19 Troubleshooting Guide Millivolt Page 20 Troubleshooting Guide Electronic Page 20 Replacement Parts List Page...

Страница 3: ...nents Any modification or alteration may void the warranty certification and listings of this unit Theseappliancesandtheirindividualshut off valves must be disconnected from the gas supply piping syst...

Страница 4: ...down until it locks in place Figure 1 OPENING CONTROL COMPARTMENT DOOR Operation of millivolt and electronic gas con trol systems are different Before lighting and operatingyourappliancedetermineifyou...

Страница 5: ...ons Electronic appliance lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve 3 Keep the lower control compartment clean by vacuuming o...

Страница 6: ...ed replacement use only the proper replacement logs from manufacturer see Pages 22 23 for ordering information Re Install Embers Logs and Vermiculite Carefully follow placement instructions on Pages 8...

Страница 7: ...front of the appliance 4 Swing the bottom of the door out and raise it slightly to lift the top flange of the door frame away from the appliance Installing Glass Enclosure Panels see Figure 6 1 Visua...

Страница 8: ...re 8 Logs should be placed in the order shown and per the following instructions WARNING DONOTattempttoinstallthelogs until the appliance installation hasbeencompleted thegasline connected and tested...

Страница 9: ...VolcanicStoneandLogsintheorder shown here 1 through 6 and per the instructions onPage8 A E B C D Vermiculite Volcanic Stone Embers DO NOT PLACE EMBERS OVER GAS SLOTS 1 2 3 4 5 6 The2notchesonlogbottom...

Страница 10: ...rrespond to photos InstalltheEmbers Vermiculite VolcanicStoneandLogsintheorder shownhere 1through6 andper theinstructionsonPage8 D C E A B 1 2 3 4 5 6 Vermiculite Volcanic Stone DONOTPLACEEMBERSOVERGA...

Страница 11: ...hanorangebodythatdoes not soot the shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines If there is smoke or soot present first check the log set positioning t...

Страница 12: ...position until the proper flame appearance is achieved 4 Leave the control knob off pilot on in the ON position and the burner OFF ON switch OFF remote switches if applicable 5 When satisfied that the...

Страница 13: ...ctlytothe appliance on a pullout panel located within the control compartment TH TP TH TP Thermopile If any of the original wire as supplied must be replaced it must be replaced with Type AWM 105o C 1...

Страница 14: ...d system may be operated with electronic and mil livoltsystemswitheithernaturalgasorpropanegas The RCL T comes complete with detailed operating instructions Remote Control Kit Deluxe Cat No Model No D...

Страница 15: ...Doors Charcoal LMDV 4035 H0967 SPD40TI 40 Sq Pane Doors Textured Iron H0968 SPD40SP 40 Sq Pane Doors Satin Pewter H0969 SPD40AB 40 Sq Pane Doors Antique Brass Arch Design Arch Pane Design Square Desi...

Страница 16: ...nce These kits can be retrofitted to previously installed appliances ref Form 750 166M Polished Brass Brushed Stainless Hood Kits Attractive hoods are available in two styles These hoods are designed...

Страница 17: ...your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a qualified service technician Force or attempted repair ma...

Страница 18: ...been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCT...

Страница 19: ...o many elbows and or exterior portions of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service...

Страница 20: ...witch is still installed on appliance it must be in the OFF position Optional remote switch kits wall switch wall thermostat or remote control A Wall switch or wires defective Check wall switch and wi...

Страница 21: ...ommon leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identify proper lead this check must be done with the valve control con nected and igniter powered NO Check t...

Страница 22: ...93L32 1 Lennox Nameplate Logo 12L15 is sold separately Gas Controls SIT Millivolt Natural Gas Propane Gas Part No Qty Part No Qty 12 Gas Valve SIT 43K07 1 88J53 1 13 Piezo Igniter 111061 1 111061 1 14...

Страница 23: ...23 NOTE DIAGRAMS ILLUSTRATIONSNOTTOSCALE REPLACEMENT PARTS 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20 31 21 8 LMDV 4035 LMDVT 3328 LMDVR 3530...

Страница 24: ...P N 875 028M REV C 06 2005 LENNOX reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult you...

Отзывы: